ABAP Select data from SAP table RPM_TS_ICORDPLN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RPM_TS_ICORDPLN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RPM_TS_ICORDPLN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RPM_TS_ICORDPLN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RPM_TS_ICORDPLN TYPE STANDARD TABLE OF RPM_TS_ICORDPLN,
      WA_RPM_TS_ICORDPLN TYPE RPM_TS_ICORDPLN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RPM_TS_ICORDPLN> TYPE RPM_TS_ICORDPLN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RPM_TS_ICORDPLN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RPM_TS_ICORDPLN
  INTO TABLE IT_RPM_TS_ICORDPLN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RPM_TS_ICORDPLN
*  INTO TABLE @DATA(IT_RPM_TS_ICORDPLN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RPM_TS_ICORDPLN INDEX 1 INTO DATA(WA_RPM_TS_ICORDPLN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RPM_TS_ICORDPLN ASSIGNING <RPM_TS_ICORDPLN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RPM_TS_ICORDPLN>-FISCVAR = 1.
<RPM_TS_ICORDPLN>-FISCYEAR = 1.
<RPM_TS_ICORDPLN>-KOKRS = 1.
<RPM_TS_ICORDPLN>-AUFNR = 1.
<RPM_TS_ICORDPLN>-AUTYP = 1.
ENDLOOP.

LOOP AT IT_RPM_TS_ICORDPLN INTO WA_RPM_TS_ICORDPLN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RPM_TS_ICORDPLN-WRTTP, sy-vline,
WA_RPM_TS_ICORDPLN-VTYPE, sy-vline,
WA_RPM_TS_ICORDPLN-VTSTAT, sy-vline,
WA_RPM_TS_ICORDPLN-VERSN, sy-vline,
WA_RPM_TS_ICORDPLN-MEASTYPE, sy-vline,
WA_RPM_TS_ICORDPLN-SWKPP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RPM_TS_ICORDPLN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RPM_TS_ICORDPLN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RPM_TS_ICORDPLN INTO WA_RPM_TS_ICORDPLN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field FISCYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_RPM_TS_ICORDPLN-FISCYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_ICORDPLN-FISCYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPM_TS_ICORDPLN-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_ICORDPLN-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPM_TS_ICORDPLN-VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_ICORDPLN-VERSN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RPM_TS_ICORDPLN_STR,
FISCVAR TYPE STRING,
FISCYEAR TYPE STRING,
KOKRS TYPE STRING,
AUFNR TYPE STRING,
AUTYP TYPE STRING,
WRTTP TYPE STRING,
VTYPE TYPE STRING,
VTSTAT TYPE STRING,
VERSN TYPE STRING,
MEASTYPE TYPE STRING,
SWKPP TYPE STRING,
SWKDP TYPE STRING,
SWLGES TYPE STRING,
WAERS TYPE STRING,
CURTYPE TYPE STRING,
OBJNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_RPM_TS_ICORDPLN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RPM_TS_ICORDPLN_STR-FISCVAR sy-vline
WA_RPM_TS_ICORDPLN_STR-FISCYEAR sy-vline
WA_RPM_TS_ICORDPLN_STR-KOKRS sy-vline
WA_RPM_TS_ICORDPLN_STR-AUFNR sy-vline
WA_RPM_TS_ICORDPLN_STR-AUTYP sy-vline
WA_RPM_TS_ICORDPLN_STR-WRTTP sy-vline
WA_RPM_TS_ICORDPLN_STR-VTYPE sy-vline
WA_RPM_TS_ICORDPLN_STR-VTSTAT sy-vline
WA_RPM_TS_ICORDPLN_STR-VERSN sy-vline
WA_RPM_TS_ICORDPLN_STR-MEASTYPE sy-vline
WA_RPM_TS_ICORDPLN_STR-SWKPP sy-vline
WA_RPM_TS_ICORDPLN_STR-SWKDP sy-vline
WA_RPM_TS_ICORDPLN_STR-SWLGES sy-vline
WA_RPM_TS_ICORDPLN_STR-WAERS sy-vline
WA_RPM_TS_ICORDPLN_STR-CURTYPE sy-vline
WA_RPM_TS_ICORDPLN_STR-OBJNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.