ABAP Select data from SAP table RPM_TS_ICCTRCST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RPM_TS_ICCTRCST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RPM_TS_ICCTRCST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RPM_TS_ICCTRCST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RPM_TS_ICCTRCST TYPE STANDARD TABLE OF RPM_TS_ICCTRCST,
      WA_RPM_TS_ICCTRCST TYPE RPM_TS_ICCTRCST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RPM_TS_ICCTRCST> TYPE RPM_TS_ICCTRCST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RPM_TS_ICCTRCST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RPM_TS_ICCTRCST
  INTO TABLE IT_RPM_TS_ICCTRCST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RPM_TS_ICCTRCST
*  INTO TABLE @DATA(IT_RPM_TS_ICCTRCST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RPM_TS_ICCTRCST INDEX 1 INTO DATA(WA_RPM_TS_ICCTRCST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RPM_TS_ICCTRCST ASSIGNING <RPM_TS_ICCTRCST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RPM_TS_ICCTRCST>-FISCVAR = 1.
<RPM_TS_ICCTRCST>-FISCPER = 1.
<RPM_TS_ICCTRCST>-KOKRS = 1.
<RPM_TS_ICCTRCST>-KOSTL = 1.
<RPM_TS_ICCTRCST>-LSTAR = 1.
ENDLOOP.

LOOP AT IT_RPM_TS_ICCTRCST INTO WA_RPM_TS_ICCTRCST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RPM_TS_ICCTRCST-WRTTP, sy-vline,
WA_RPM_TS_ICCTRCST-HRKFT, sy-vline,
WA_RPM_TS_ICCTRCST-VTYPE, sy-vline,
WA_RPM_TS_ICCTRCST-VTDETAIL, sy-vline,
WA_RPM_TS_ICCTRCST-VTSTAT, sy-vline,
WA_RPM_TS_ICCTRCST-VERSN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RPM_TS_ICCTRCST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RPM_TS_ICCTRCST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RPM_TS_ICCTRCST INTO WA_RPM_TS_ICCTRCST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PERI7, internal->external for field FISCPER CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_RPM_TS_ICCTRCST-FISCPER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_ICCTRCST-FISCPER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPM_TS_ICCTRCST-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_ICCTRCST-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPM_TS_ICCTRCST-VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_ICCTRCST-VERSN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KSTAR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPM_TS_ICCTRCST-KSTAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_ICCTRCST-KSTAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SWG CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_RPM_TS_ICCTRCST-SWG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_ICCTRCST-SWG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SWF CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_RPM_TS_ICCTRCST-SWF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_ICCTRCST-SWF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SWV CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_RPM_TS_ICCTRCST-SWV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_ICCTRCST-SWV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RPM_TS_ICCTRCST-MEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_ICCTRCST-MEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GRANT_NBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPM_TS_ICCTRCST-GRANT_NBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_ICCTRCST-GRANT_NBR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PGRANT_NBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPM_TS_ICCTRCST-PGRANT_NBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_ICCTRCST-PGRANT_NBR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RPM_TS_ICCTRCST_STR,
FISCVAR TYPE STRING,
FISCPER TYPE STRING,
KOKRS TYPE STRING,
KOSTL TYPE STRING,
LSTAR TYPE STRING,
WRTTP TYPE STRING,
HRKFT TYPE STRING,
VTYPE TYPE STRING,
VTDETAIL TYPE STRING,
VTSTAT TYPE STRING,
VERSN TYPE STRING,
KSTAR TYPE STRING,
SEKNZ TYPE STRING,
RSPOBART TYPE STRING,
RSPAROBVAL TYPE STRING,
VALUTYP TYPE STRING,
MEASTYPE TYPE STRING,
CORRTYPE TYPE STRING,
CCTR_IBV TYPE STRING,
SWG TYPE STRING,
SWF TYPE STRING,
SWV TYPE STRING,
SME TYPE STRING,
SMA TYPE STRING,
SMEG TYPE STRING,
SMEF TYPE STRING,
SMEV TYPE STRING,
WAERS TYPE STRING,
CURTYPE TYPE STRING,
MEINH TYPE STRING,
GEBER TYPE STRING,
PGEBER TYPE STRING,
FKBER TYPE STRING,
PFKBER TYPE STRING,
GRANT_NBR TYPE STRING,
PGRANT_NBR TYPE STRING,
FIKRS TYPE STRING,
BUDGET_PD TYPE STRING,
PBUDGET_PD TYPE STRING,END OF T_EKKO_STR. DATA: WA_RPM_TS_ICCTRCST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RPM_TS_ICCTRCST_STR-FISCVAR sy-vline
WA_RPM_TS_ICCTRCST_STR-FISCPER sy-vline
WA_RPM_TS_ICCTRCST_STR-KOKRS sy-vline
WA_RPM_TS_ICCTRCST_STR-KOSTL sy-vline
WA_RPM_TS_ICCTRCST_STR-LSTAR sy-vline
WA_RPM_TS_ICCTRCST_STR-WRTTP sy-vline
WA_RPM_TS_ICCTRCST_STR-HRKFT sy-vline
WA_RPM_TS_ICCTRCST_STR-VTYPE sy-vline
WA_RPM_TS_ICCTRCST_STR-VTDETAIL sy-vline
WA_RPM_TS_ICCTRCST_STR-VTSTAT sy-vline
WA_RPM_TS_ICCTRCST_STR-VERSN sy-vline
WA_RPM_TS_ICCTRCST_STR-KSTAR sy-vline
WA_RPM_TS_ICCTRCST_STR-SEKNZ sy-vline
WA_RPM_TS_ICCTRCST_STR-RSPOBART sy-vline
WA_RPM_TS_ICCTRCST_STR-RSPAROBVAL sy-vline
WA_RPM_TS_ICCTRCST_STR-VALUTYP sy-vline
WA_RPM_TS_ICCTRCST_STR-MEASTYPE sy-vline
WA_RPM_TS_ICCTRCST_STR-CORRTYPE sy-vline
WA_RPM_TS_ICCTRCST_STR-CCTR_IBV sy-vline
WA_RPM_TS_ICCTRCST_STR-SWG sy-vline
WA_RPM_TS_ICCTRCST_STR-SWF sy-vline
WA_RPM_TS_ICCTRCST_STR-SWV sy-vline
WA_RPM_TS_ICCTRCST_STR-SME sy-vline
WA_RPM_TS_ICCTRCST_STR-SMA sy-vline
WA_RPM_TS_ICCTRCST_STR-SMEG sy-vline
WA_RPM_TS_ICCTRCST_STR-SMEF sy-vline
WA_RPM_TS_ICCTRCST_STR-SMEV sy-vline
WA_RPM_TS_ICCTRCST_STR-WAERS sy-vline
WA_RPM_TS_ICCTRCST_STR-CURTYPE sy-vline
WA_RPM_TS_ICCTRCST_STR-MEINH sy-vline
WA_RPM_TS_ICCTRCST_STR-GEBER sy-vline
WA_RPM_TS_ICCTRCST_STR-PGEBER sy-vline
WA_RPM_TS_ICCTRCST_STR-FKBER sy-vline
WA_RPM_TS_ICCTRCST_STR-PFKBER sy-vline
WA_RPM_TS_ICCTRCST_STR-GRANT_NBR sy-vline
WA_RPM_TS_ICCTRCST_STR-PGRANT_NBR sy-vline
WA_RPM_TS_ICCTRCST_STR-FIKRS sy-vline
WA_RPM_TS_ICCTRCST_STR-BUDGET_PD sy-vline
WA_RPM_TS_ICCTRCST_STR-PBUDGET_PD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.