ABAP Select data from SAP table RPM_TS_FIINTF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RPM_TS_FIINTF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RPM_TS_FIINTF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RPM_TS_FIINTF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RPM_TS_FIINTF TYPE STANDARD TABLE OF RPM_TS_FIINTF,
      WA_RPM_TS_FIINTF TYPE RPM_TS_FIINTF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RPM_TS_FIINTF> TYPE RPM_TS_FIINTF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RPM_TS_FIINTF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RPM_TS_FIINTF
  INTO TABLE IT_RPM_TS_FIINTF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RPM_TS_FIINTF
*  INTO TABLE @DATA(IT_RPM_TS_FIINTF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RPM_TS_FIINTF INDEX 1 INTO DATA(WA_RPM_TS_FIINTF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RPM_TS_FIINTF ASSIGNING <RPM_TS_FIINTF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RPM_TS_FIINTF>-PROJID = 1.
<RPM_TS_FIINTF>-TASKID = 1.
<RPM_TS_FIINTF>-OBJLINK = 1.
<RPM_TS_FIINTF>-VERSION = 1.
<RPM_TS_FIINTF>-FISCYEAR = 1.
ENDLOOP.

LOOP AT IT_RPM_TS_FIINTF INTO WA_RPM_TS_FIINTF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RPM_TS_FIINTF-VALTYPE, sy-vline,
WA_RPM_TS_FIINTF-COSTCAT, sy-vline,
WA_RPM_TS_FIINTF-PERTYPE, sy-vline,
WA_RPM_TS_FIINTF-PERID, sy-vline,
WA_RPM_TS_FIINTF-STRTDATE, sy-vline,
WA_RPM_TS_FIINTF-ENDDATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RPM_TS_FIINTF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RPM_TS_FIINTF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RPM_TS_FIINTF INTO WA_RPM_TS_FIINTF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPM_TS_FIINTF-VERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_FIINTF-VERSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field FISCYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_RPM_TS_FIINTF-FISCYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPM_TS_FIINTF-FISCYEAR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RPM_TS_FIINTF_STR,
PROJID TYPE STRING,
TASKID TYPE STRING,
OBJLINK TYPE STRING,
VERSION TYPE STRING,
FISCYEAR TYPE STRING,
VALTYPE TYPE STRING,
COSTCAT TYPE STRING,
PERTYPE TYPE STRING,
PERID TYPE STRING,
STRTDATE TYPE STRING,
ENDDATE TYPE STRING,
AMOUNT TYPE STRING,
CURRENCY TYPE STRING,
PHASE TYPE STRING,
ORGTYPE TYPE STRING,
ORGID TYPE STRING,END OF T_EKKO_STR. DATA: WA_RPM_TS_FIINTF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RPM_TS_FIINTF_STR-PROJID sy-vline
WA_RPM_TS_FIINTF_STR-TASKID sy-vline
WA_RPM_TS_FIINTF_STR-OBJLINK sy-vline
WA_RPM_TS_FIINTF_STR-VERSION sy-vline
WA_RPM_TS_FIINTF_STR-FISCYEAR sy-vline
WA_RPM_TS_FIINTF_STR-VALTYPE sy-vline
WA_RPM_TS_FIINTF_STR-COSTCAT sy-vline
WA_RPM_TS_FIINTF_STR-PERTYPE sy-vline
WA_RPM_TS_FIINTF_STR-PERID sy-vline
WA_RPM_TS_FIINTF_STR-STRTDATE sy-vline
WA_RPM_TS_FIINTF_STR-ENDDATE sy-vline
WA_RPM_TS_FIINTF_STR-AMOUNT sy-vline
WA_RPM_TS_FIINTF_STR-CURRENCY sy-vline
WA_RPM_TS_FIINTF_STR-PHASE sy-vline
WA_RPM_TS_FIINTF_STR-ORGTYPE sy-vline
WA_RPM_TS_FIINTF_STR-ORGID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.