ABAP Select data from SAP table RPLM_TS_TECHOBJ_ADDR_UI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RPLM_TS_TECHOBJ_ADDR_UI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RPLM_TS_TECHOBJ_ADDR_UI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RPLM_TS_TECHOBJ_ADDR_UI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RPLM_TS_TECHOBJ_ADDR_UI TYPE STANDARD TABLE OF RPLM_TS_TECHOBJ_ADDR_UI,
      WA_RPLM_TS_TECHOBJ_ADDR_UI TYPE RPLM_TS_TECHOBJ_ADDR_UI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RPLM_TS_TECHOBJ_ADDR_UI> TYPE RPLM_TS_TECHOBJ_ADDR_UI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RPLM_TS_TECHOBJ_ADDR_UI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RPLM_TS_TECHOBJ_ADDR_UI
  INTO TABLE IT_RPLM_TS_TECHOBJ_ADDR_UI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RPLM_TS_TECHOBJ_ADDR_UI
*  INTO TABLE @DATA(IT_RPLM_TS_TECHOBJ_ADDR_UI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RPLM_TS_TECHOBJ_ADDR_UI INDEX 1 INTO DATA(WA_RPLM_TS_TECHOBJ_ADDR_UI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RPLM_TS_TECHOBJ_ADDR_UI ASSIGNING <RPLM_TS_TECHOBJ_ADDR_UI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RPLM_TS_TECHOBJ_ADDR_UI>-MANDT = 1.
<RPLM_TS_TECHOBJ_ADDR_UI>-ADRNR = 1.
<RPLM_TS_TECHOBJ_ADDR_UI>-NATIO = 1.
<RPLM_TS_TECHOBJ_ADDR_UI>-ANRED = 1.
<RPLM_TS_TECHOBJ_ADDR_UI>-NAME1 = 1.
ENDLOOP.

LOOP AT IT_RPLM_TS_TECHOBJ_ADDR_UI INTO WA_RPLM_TS_TECHOBJ_ADDR_UI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RPLM_TS_TECHOBJ_ADDR_UI-NAME2, sy-vline,
WA_RPLM_TS_TECHOBJ_ADDR_UI-NAME3, sy-vline,
WA_RPLM_TS_TECHOBJ_ADDR_UI-NAME4, sy-vline,
WA_RPLM_TS_TECHOBJ_ADDR_UI-PSTLZ, sy-vline,
WA_RPLM_TS_TECHOBJ_ADDR_UI-ORT01, sy-vline,
WA_RPLM_TS_TECHOBJ_ADDR_UI-ORT02, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RPLM_TS_TECHOBJ_ADDR_UI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RPLM_TS_TECHOBJ_ADDR_UI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RPLM_TS_TECHOBJ_ADDR_UI INTO WA_RPLM_TS_TECHOBJ_ADDR_UI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ADRNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_TECHOBJ_ADDR_UI-ADRNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_TECHOBJ_ADDR_UI-ADRNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_RPLM_TS_TECHOBJ_ADDR_UI-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_TECHOBJ_ADDR_UI-SPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RPLM_TS_TECHOBJ_ADDR_UI_STR,
MANDT TYPE STRING,
ADRNR TYPE STRING,
NATIO TYPE STRING,
ANRED TYPE STRING,
NAME1 TYPE STRING,
NAME2 TYPE STRING,
NAME3 TYPE STRING,
NAME4 TYPE STRING,
PSTLZ TYPE STRING,
ORT01 TYPE STRING,
ORT02 TYPE STRING,
PSTL2 TYPE STRING,
PFACH TYPE STRING,
STRAS TYPE STRING,
STRS2 TYPE STRING,
HAUSN TYPE STRING,
STOCK TYPE STRING,
LAND1 TYPE STRING,
SORTL TYPE STRING,
SORT2 TYPE STRING,
SPRAS TYPE STRING,
LZONE TYPE STRING,
REGIO TYPE STRING,
PSTBZ TYPE STRING,
TELF1 TYPE STRING,
FLAG TYPE STRING,
TELFX TYPE STRING,
FLAG2 TYPE STRING,
TELTX TYPE STRING,
FLAG3 TYPE STRING,
TELX1 TYPE STRING,
FLAG4 TYPE STRING,
MAIAD TYPE STRING,
MAILN TYPE STRING,
STDKO TYPE STRING,
STDCOM TYPE STRING,
DBNAME TYPE STRING,
KLASSE TYPE STRING,
ANREK TYPE STRING,
CRNAM TYPE STRING,
CRDAT TYPE STRING,
CRTIM TYPE STRING,
CHNAM TYPE STRING,
CHDAT TYPE STRING,
CHTIM TYPE STRING,
DUEFL TYPE STRING,
TXJCD TYPE STRING,
PFORT TYPE STRING,
TZONE TYPE STRING,END OF T_EKKO_STR. DATA: WA_RPLM_TS_TECHOBJ_ADDR_UI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-MANDT sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-ADRNR sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-NATIO sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-ANRED sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-NAME1 sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-NAME2 sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-NAME3 sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-NAME4 sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-PSTLZ sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-ORT01 sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-ORT02 sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-PSTL2 sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-PFACH sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-STRAS sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-STRS2 sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-HAUSN sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-STOCK sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-LAND1 sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-SORTL sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-SORT2 sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-SPRAS sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-LZONE sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-REGIO sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-PSTBZ sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-TELF1 sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-FLAG sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-TELFX sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-FLAG2 sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-TELTX sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-FLAG3 sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-TELX1 sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-FLAG4 sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-MAIAD sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-MAILN sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-STDKO sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-STDCOM sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-DBNAME sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-KLASSE sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-ANREK sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-CRNAM sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-CRDAT sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-CRTIM sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-CHNAM sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-CHDAT sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-CHTIM sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-DUEFL sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-TXJCD sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-PFORT sy-vline
WA_RPLM_TS_TECHOBJ_ADDR_UI_STR-TZONE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.