ABAP Select data from SAP table RPLM_TS_POWL_TASK_LISTS_INFO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RPLM_TS_POWL_TASK_LISTS_INFO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RPLM_TS_POWL_TASK_LISTS_INFO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RPLM_TS_POWL_TASK_LISTS_INFO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RPLM_TS_POWL_TASK_LISTS_INFO TYPE STANDARD TABLE OF RPLM_TS_POWL_TASK_LISTS_INFO,
      WA_RPLM_TS_POWL_TASK_LISTS_INFO TYPE RPLM_TS_POWL_TASK_LISTS_INFO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RPLM_TS_POWL_TASK_LISTS_INFO> TYPE RPLM_TS_POWL_TASK_LISTS_INFO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RPLM_TS_POWL_TASK_LISTS_INFO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RPLM_TS_POWL_TASK_LISTS_INFO
  INTO TABLE IT_RPLM_TS_POWL_TASK_LISTS_INFO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RPLM_TS_POWL_TASK_LISTS_INFO
*  INTO TABLE @DATA(IT_RPLM_TS_POWL_TASK_LISTS_INFO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RPLM_TS_POWL_TASK_LISTS_INFO INDEX 1 INTO DATA(WA_RPLM_TS_POWL_TASK_LISTS_INFO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RPLM_TS_POWL_TASK_LISTS_INFO ASSIGNING <RPLM_TS_POWL_TASK_LISTS_INFO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RPLM_TS_POWL_TASK_LISTS_INFO>-PLNTY = 1.
<RPLM_TS_POWL_TASK_LISTS_INFO>-PLNNR = 1.
<RPLM_TS_POWL_TASK_LISTS_INFO>-PLNAL = 1.
<RPLM_TS_POWL_TASK_LISTS_INFO>-DATUV = 1.
<RPLM_TS_POWL_TASK_LISTS_INFO>-TECHV = 1.
ENDLOOP.

LOOP AT IT_RPLM_TS_POWL_TASK_LISTS_INFO INTO WA_RPLM_TS_POWL_TASK_LISTS_INFO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RPLM_TS_POWL_TASK_LISTS_INFO-AENNR, sy-vline,
WA_RPLM_TS_POWL_TASK_LISTS_INFO-LOEKZ, sy-vline,
WA_RPLM_TS_POWL_TASK_LISTS_INFO-ANDAT, sy-vline,
WA_RPLM_TS_POWL_TASK_LISTS_INFO-ANNAM, sy-vline,
WA_RPLM_TS_POWL_TASK_LISTS_INFO-AEDAT, sy-vline,
WA_RPLM_TS_POWL_TASK_LISTS_INFO-AENAM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RPLM_TS_POWL_TASK_LISTS_INFO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RPLM_TS_POWL_TASK_LISTS_INFO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RPLM_TS_POWL_TASK_LISTS_INFO INTO WA_RPLM_TS_POWL_TASK_LISTS_INFO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_TASK_LISTS_INFO-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_TASK_LISTS_INFO-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_TASK_LISTS_INFO-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_TASK_LISTS_INFO-PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_TASK_LISTS_INFO-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_TASK_LISTS_INFO-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_TASK_LISTS_INFO-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_TASK_LISTS_INFO-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ISTRU CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_TASK_LISTS_INFO-ISTRU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_TASK_LISTS_INFO-ISTRU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RPLM_TS_POWL_TASK_LISTS_INFO_STR,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
DATUV TYPE STRING,
TECHV TYPE STRING,
AENNR TYPE STRING,
LOEKZ TYPE STRING,
ANDAT TYPE STRING,
ANNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
VERWE TYPE STRING,
WERKS TYPE STRING,
STATU TYPE STRING,
VAGRP TYPE STRING,
KTEXT TYPE STRING,
KOKRS TYPE STRING,
STRAT TYPE STRING,
TPLNR TYPE STRING,
EQUNR TYPE STRING,
ISTRU TYPE STRING,
ANLZU TYPE STRING,
ARBPL TYPE STRING,
DELKZ TYPE STRING,
SLWBEZ TYPE STRING,
AWERK TYPE STRING,
EXTNUM TYPE STRING,
/CUM/INTCUNR TYPE STRING,
TL_EXTID TYPE STRING,
XHIERTL TYPE STRING,
ADPSP TYPE STRING,END OF T_EKKO_STR. DATA: WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-PLNTY sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-PLNNR sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-PLNAL sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-DATUV sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-TECHV sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-AENNR sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-LOEKZ sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-ANDAT sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-ANNAM sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-AEDAT sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-AENAM sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-VERWE sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-WERKS sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-STATU sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-VAGRP sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-KTEXT sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-KOKRS sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-STRAT sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-TPLNR sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-EQUNR sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-ISTRU sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-ANLZU sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-ARBPL sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-DELKZ sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-SLWBEZ sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-AWERK sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-EXTNUM sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-/CUM/INTCUNR sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-TL_EXTID sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-XHIERTL sy-vline
WA_RPLM_TS_POWL_TASK_LISTS_INFO_STR-ADPSP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.