ABAP Select data from SAP table RPLM_TS_POWL_NOTIF_PM_DEF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RPLM_TS_POWL_NOTIF_PM_DEF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RPLM_TS_POWL_NOTIF_PM_DEF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RPLM_TS_POWL_NOTIF_PM_DEF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RPLM_TS_POWL_NOTIF_PM_DEF TYPE STANDARD TABLE OF RPLM_TS_POWL_NOTIF_PM_DEF,
      WA_RPLM_TS_POWL_NOTIF_PM_DEF TYPE RPLM_TS_POWL_NOTIF_PM_DEF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RPLM_TS_POWL_NOTIF_PM_DEF> TYPE RPLM_TS_POWL_NOTIF_PM_DEF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RPLM_TS_POWL_NOTIF_PM_DEF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RPLM_TS_POWL_NOTIF_PM_DEF
  INTO TABLE IT_RPLM_TS_POWL_NOTIF_PM_DEF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RPLM_TS_POWL_NOTIF_PM_DEF
*  INTO TABLE @DATA(IT_RPLM_TS_POWL_NOTIF_PM_DEF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RPLM_TS_POWL_NOTIF_PM_DEF INDEX 1 INTO DATA(WA_RPLM_TS_POWL_NOTIF_PM_DEF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RPLM_TS_POWL_NOTIF_PM_DEF ASSIGNING <RPLM_TS_POWL_NOTIF_PM_DEF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RPLM_TS_POWL_NOTIF_PM_DEF>-QMNUM = 1.
<RPLM_TS_POWL_NOTIF_PM_DEF>-QMTXT = 1.
<RPLM_TS_POWL_NOTIF_PM_DEF>-TPLNR = 1.
<RPLM_TS_POWL_NOTIF_PM_DEF>-PLTXT = 1.
<RPLM_TS_POWL_NOTIF_PM_DEF>-EQUNR = 1.
ENDLOOP.

LOOP AT IT_RPLM_TS_POWL_NOTIF_PM_DEF INTO WA_RPLM_TS_POWL_NOTIF_PM_DEF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RPLM_TS_POWL_NOTIF_PM_DEF-EQKTX, sy-vline,
WA_RPLM_TS_POWL_NOTIF_PM_DEF-QMART, sy-vline,
WA_RPLM_TS_POWL_NOTIF_PM_DEF-ARBPL, sy-vline,
WA_RPLM_TS_POWL_NOTIF_PM_DEF-STRMN, sy-vline,
WA_RPLM_TS_POWL_NOTIF_PM_DEF-LTRMN, sy-vline,
WA_RPLM_TS_POWL_NOTIF_PM_DEF-MSAUS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RPLM_TS_POWL_NOTIF_PM_DEF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RPLM_TS_POWL_NOTIF_PM_DEF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RPLM_TS_POWL_NOTIF_PM_DEF INTO WA_RPLM_TS_POWL_NOTIF_PM_DEF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field QMNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_PM_DEF-QMNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_PM_DEF-QMNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_PM_DEF-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_PM_DEF-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field BAUTL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_PM_DEF-BAUTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_PM_DEF-BAUTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERIALNR CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_PM_DEF-SERIALNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_PM_DEF-SERIALNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WARPL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_PM_DEF-WARPL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_PM_DEF-WARPL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WAPOS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_PM_DEF-WAPOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_PM_DEF-WAPOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RPLM_TS_POWL_NOTIF_PM_DEF-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RPLM_TS_POWL_NOTIF_PM_DEF-AUFNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RPLM_TS_POWL_NOTIF_PM_DEF_STR,
QMNUM TYPE STRING,
QMTXT TYPE STRING,
TPLNR TYPE STRING,
PLTXT TYPE STRING,
EQUNR TYPE STRING,
EQKTX TYPE STRING,
QMART TYPE STRING,
ARBPL TYPE STRING,
STRMN TYPE STRING,
LTRMN TYPE STRING,
MSAUS TYPE STRING,
PRIOK TYPE STRING,
QMDAT TYPE STRING,
STORT TYPE STRING,
BEBER TYPE STRING,
BAUTL TYPE STRING,
BAUTLX TYPE STRING,
AUSVN TYPE STRING,
AUZTV TYPE STRING,
AUSBS TYPE STRING,
AUZTB TYPE STRING,
AUSWK TYPE STRING,
INGRP TYPE STRING,
ERNAM TYPE STRING,
ERDAT TYPE STRING,
AENAM TYPE STRING,
AEDAT TYPE STRING,
AEZEIT TYPE STRING,
MZEIT TYPE STRING,
QMNAM TYPE STRING,
SPART TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SERIALNR TYPE STRING,
MSGRP TYPE STRING,
WARPL TYPE STRING,
WAPOS TYPE STRING,
KTXTCD TYPE STRING,
INDTX TYPE STRING,
STTXT TYPE STRING,
USTXT TYPE STRING,
DOCNUM TYPE STRING,
OBJNR TYPE STRING,
AUFNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-QMNUM sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-QMTXT sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-TPLNR sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-PLTXT sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-EQUNR sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-EQKTX sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-QMART sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-ARBPL sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-STRMN sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-LTRMN sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-MSAUS sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-PRIOK sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-QMDAT sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-STORT sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-BEBER sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-BAUTL sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-BAUTLX sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-AUSVN sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-AUZTV sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-AUSBS sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-AUZTB sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-AUSWK sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-INGRP sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-ERNAM sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-ERDAT sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-AENAM sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-AEDAT sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-AEZEIT sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-MZEIT sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-QMNAM sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-SPART sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-VKORG sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-VTWEG sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-SERIALNR sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-MSGRP sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-WARPL sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-WAPOS sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-KTXTCD sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-INDTX sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-STTXT sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-USTXT sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-DOCNUM sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-OBJNR sy-vline
WA_RPLM_TS_POWL_NOTIF_PM_DEF_STR-AUFNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.