ABAP Select data from SAP table ROXXB40065 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROXXB40065 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROXXB40065. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROXXB40065 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROXXB40065 TYPE STANDARD TABLE OF ROXXB40065,
      WA_ROXXB40065 TYPE ROXXB40065,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROXXB40065> TYPE ROXXB40065.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROXXB40065.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROXXB40065
  INTO TABLE IT_ROXXB40065.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROXXB40065
*  INTO TABLE @DATA(IT_ROXXB400652).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROXXB40065 INDEX 1 INTO DATA(WA_ROXXB400652).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROXXB40065 ASSIGNING <ROXXB40065>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROXXB40065>-MANDT = 1.
<ROXXB40065>-NODE = 1.
<ROXXB40065>-DATE_FROM = 1.
<ROXXB40065>-DATE_TO = 1.
<ROXXB40065>-ROLE = 1.
ENDLOOP.

LOOP AT IT_ROXXB40065 INTO WA_ROXXB40065.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROXXB40065-STRATEGY, sy-vline,
WA_ROXXB40065-HIER_ID, sy-vline,
WA_ROXXB40065-PARENT, sy-vline,
WA_ROXXB40065-HIERNODE1, sy-vline,
WA_ROXXB40065-HIERNODE2, sy-vline,
WA_ROXXB40065-VKORG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROXXB40065 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROXXB40065 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROXXB40065 INTO WA_ROXXB40065. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field SPACEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROXXB40065-SPACEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROXXB40065-SPACEUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LINUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROXXB40065-LINUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROXXB40065-LINUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROXXB40065_STR,
MANDT TYPE STRING,
NODE TYPE STRING,
DATE_FROM TYPE STRING,
DATE_TO TYPE STRING,
ROLE TYPE STRING,
STRATEGY TYPE STRING,
HIER_ID TYPE STRING,
PARENT TYPE STRING,
HIERNODE1 TYPE STRING,
HIERNODE2 TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
TREE_LEVEL TYPE STRING,
SHLFSPC TYPE STRING,
LINSPC TYPE STRING,
SPACEUNIT TYPE STRING,
LINUNIT TYPE STRING,
STORES TYPE STRING,
CHKDATE TYPE STRING,
TIMESTAMP TYPE STRING,
DELETEFLAG TYPE STRING,
EPRGR TYPE STRING,
PRODUCTCLF TYPE STRING,
PRICE_GROUP TYPE STRING,
REFERENCE TYPE STRING,
RESPONSIBILITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROXXB40065_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROXXB40065_STR-MANDT sy-vline
WA_ROXXB40065_STR-NODE sy-vline
WA_ROXXB40065_STR-DATE_FROM sy-vline
WA_ROXXB40065_STR-DATE_TO sy-vline
WA_ROXXB40065_STR-ROLE sy-vline
WA_ROXXB40065_STR-STRATEGY sy-vline
WA_ROXXB40065_STR-HIER_ID sy-vline
WA_ROXXB40065_STR-PARENT sy-vline
WA_ROXXB40065_STR-HIERNODE1 sy-vline
WA_ROXXB40065_STR-HIERNODE2 sy-vline
WA_ROXXB40065_STR-VKORG sy-vline
WA_ROXXB40065_STR-VTWEG sy-vline
WA_ROXXB40065_STR-TREE_LEVEL sy-vline
WA_ROXXB40065_STR-SHLFSPC sy-vline
WA_ROXXB40065_STR-LINSPC sy-vline
WA_ROXXB40065_STR-SPACEUNIT sy-vline
WA_ROXXB40065_STR-LINUNIT sy-vline
WA_ROXXB40065_STR-STORES sy-vline
WA_ROXXB40065_STR-CHKDATE sy-vline
WA_ROXXB40065_STR-TIMESTAMP sy-vline
WA_ROXXB40065_STR-DELETEFLAG sy-vline
WA_ROXXB40065_STR-EPRGR sy-vline
WA_ROXXB40065_STR-PRODUCTCLF sy-vline
WA_ROXXB40065_STR-PRICE_GROUP sy-vline
WA_ROXXB40065_STR-REFERENCE sy-vline
WA_ROXXB40065_STR-RESPONSIBILITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.