ABAP Select data from SAP table ROXE390111 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROXE390111 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROXE390111. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ROXE390111 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ROXE390111 TYPE STANDARD TABLE OF ROXE390111, WA_ROXE390111 TYPE ROXE390111, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ROXE390111> TYPE ROXE390111. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ROXE390111. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ROXE390111 INTO TABLE IT_ROXE390111. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ROXE390111 * INTO TABLE @DATA(IT_ROXE3901112). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ROXE390111 INDEX 1 INTO DATA(WA_ROXE3901112). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ROXE390111 ASSIGNING <ROXE390111>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROXE390111>-MANDT = 1.
<ROXE390111>-BUKRS = 1.
<ROXE390111>-COUNTRY_VAR = 1.
<ROXE390111>-STICHTAG_FONDS = 1.
<ROXE390111>-ASSET_NR = 1.
ENDLOOP. LOOP AT IT_ROXE390111 INTO WA_ROXE390111. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ROXE390111-PRODUCT_CATEGORY, sy-vline,
WA_ROXE390111-PRODUCT_TYPE, sy-vline,
WA_ROXE390111-RANTYP, sy-vline,
WA_ROXE390111-BONITAET, sy-vline,
WA_ROXE390111-ART_PRODUCT, sy-vline,
WA_ROXE390111-ABS_CLN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROXE390111 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROXE390111 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROXE390111 INTO WA_ROXE390111. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field ASSET_NR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROXE390111-ASSET_NR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROXE390111-ASSET_NR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROXE390111_STR,
MANDT TYPE STRING,
BUKRS TYPE STRING,
COUNTRY_VAR TYPE STRING,
STICHTAG_FONDS TYPE STRING,
ASSET_NR TYPE STRING,
PRODUCT_CATEGORY TYPE STRING,
PRODUCT_TYPE TYPE STRING,
RANTYP TYPE STRING,
BONITAET TYPE STRING,
ART_PRODUCT TYPE STRING,
ABS_CLN TYPE STRING,
R3_1999 TYPE STRING,
R3_2000 TYPE STRING,
R1_2002 TYPE STRING,
FLG_PRIVATE_CAP TYPE STRING,
RATING_COMPANY TYPE STRING,
ISSR_RATING TYPE STRING,
FLG_CAP_GUARANTY TYPE STRING,
FLG_NEG_INTEREST TYPE STRING,
PORTFOLIO TYPE STRING,
FLG_P77A4VAG TYPE STRING,
FLG_HF_BOUND TYPE STRING,
FLG_HF_RETURN TYPE STRING,
FLG_HF_INDICES TYPE STRING,
HF_LOCATION TYPE STRING,
FLG_MAX_YLD TYPE STRING,
FLG_CALLABLE TYPE STRING,
ABS TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROXE390111_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROXE390111_STR-MANDT sy-vline
WA_ROXE390111_STR-BUKRS sy-vline
WA_ROXE390111_STR-COUNTRY_VAR sy-vline
WA_ROXE390111_STR-STICHTAG_FONDS sy-vline
WA_ROXE390111_STR-ASSET_NR sy-vline
WA_ROXE390111_STR-PRODUCT_CATEGORY sy-vline
WA_ROXE390111_STR-PRODUCT_TYPE sy-vline
WA_ROXE390111_STR-RANTYP sy-vline
WA_ROXE390111_STR-BONITAET sy-vline
WA_ROXE390111_STR-ART_PRODUCT sy-vline
WA_ROXE390111_STR-ABS_CLN sy-vline
WA_ROXE390111_STR-R3_1999 sy-vline
WA_ROXE390111_STR-R3_2000 sy-vline
WA_ROXE390111_STR-R1_2002 sy-vline
WA_ROXE390111_STR-FLG_PRIVATE_CAP sy-vline
WA_ROXE390111_STR-RATING_COMPANY sy-vline
WA_ROXE390111_STR-ISSR_RATING sy-vline
WA_ROXE390111_STR-FLG_CAP_GUARANTY sy-vline
WA_ROXE390111_STR-FLG_NEG_INTEREST sy-vline
WA_ROXE390111_STR-PORTFOLIO sy-vline
WA_ROXE390111_STR-FLG_P77A4VAG sy-vline
WA_ROXE390111_STR-FLG_HF_BOUND sy-vline
WA_ROXE390111_STR-FLG_HF_RETURN sy-vline
WA_ROXE390111_STR-FLG_HF_INDICES sy-vline
WA_ROXE390111_STR-HF_LOCATION sy-vline
WA_ROXE390111_STR-FLG_MAX_YLD sy-vline
WA_ROXE390111_STR-FLG_CALLABLE sy-vline
WA_ROXE390111_STR-ABS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.