ABAP Select data from SAP table ROXAX80058 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROXAX80058 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROXAX80058. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROXAX80058 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROXAX80058 TYPE STANDARD TABLE OF ROXAX80058,
      WA_ROXAX80058 TYPE ROXAX80058,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROXAX80058> TYPE ROXAX80058.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROXAX80058.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROXAX80058
  INTO TABLE IT_ROXAX80058.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROXAX80058
*  INTO TABLE @DATA(IT_ROXAX800582).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROXAX80058 INDEX 1 INTO DATA(WA_ROXAX800582).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROXAX80058 ASSIGNING <ROXAX80058>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROXAX80058>-MANDT = 1.
<ROXAX80058>-MATNR = 1.
<ROXAX80058>-HIER_ID = 1.
<ROXAX80058>-STRATEGY = 1.
<ROXAX80058>-CDT1 = 1.
ENDLOOP.

LOOP AT IT_ROXAX80058 INTO WA_ROXAX80058.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROXAX80058-CDT2, sy-vline,
WA_ROXAX80058-CDT3, sy-vline,
WA_ROXAX80058-CDT4, sy-vline,
WA_ROXAX80058-CDT5, sy-vline,
WA_ROXAX80058-CDT6, sy-vline,
WA_ROXAX80058-CDT7, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROXAX80058 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROXAX80058 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROXAX80058 INTO WA_ROXAX80058. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ROXAX80058-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROXAX80058-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field SPACEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROXAX80058-SPACEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROXAX80058-SPACEUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LINUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROXAX80058-LINUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROXAX80058-LINUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EAN11, internal->external for field EAN11 CALL FUNCTION 'CONVERSION_EXIT_EAN11_OUTPUT' EXPORTING input = WA_ROXAX80058-EAN11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROXAX80058-EAN11.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROXAX80058_STR,
MANDT TYPE STRING,
MATNR TYPE STRING,
HIER_ID TYPE STRING,
STRATEGY TYPE STRING,
CDT1 TYPE STRING,
CDT2 TYPE STRING,
CDT3 TYPE STRING,
CDT4 TYPE STRING,
CDT5 TYPE STRING,
CDT6 TYPE STRING,
CDT7 TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SHLFSPC TYPE STRING,
LINSPC TYPE STRING,
SPACEUNIT TYPE STRING,
LINUNIT TYPE STRING,
CHKDATE TYPE STRING,
EAN11 TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROXAX80058_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROXAX80058_STR-MANDT sy-vline
WA_ROXAX80058_STR-MATNR sy-vline
WA_ROXAX80058_STR-HIER_ID sy-vline
WA_ROXAX80058_STR-STRATEGY sy-vline
WA_ROXAX80058_STR-CDT1 sy-vline
WA_ROXAX80058_STR-CDT2 sy-vline
WA_ROXAX80058_STR-CDT3 sy-vline
WA_ROXAX80058_STR-CDT4 sy-vline
WA_ROXAX80058_STR-CDT5 sy-vline
WA_ROXAX80058_STR-CDT6 sy-vline
WA_ROXAX80058_STR-CDT7 sy-vline
WA_ROXAX80058_STR-VKORG sy-vline
WA_ROXAX80058_STR-VTWEG sy-vline
WA_ROXAX80058_STR-SHLFSPC sy-vline
WA_ROXAX80058_STR-LINSPC sy-vline
WA_ROXAX80058_STR-SPACEUNIT sy-vline
WA_ROXAX80058_STR-LINUNIT sy-vline
WA_ROXAX80058_STR-CHKDATE sy-vline
WA_ROXAX80058_STR-EAN11 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.