ABAP Select data from SAP table ROIUX6_WY_STAXHST_TC_0300 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIUX6_WY_STAXHST_TC_0300 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIUX6_WY_STAXHST_TC_0300. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIUX6_WY_STAXHST_TC_0300 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIUX6_WY_STAXHST_TC_0300 TYPE STANDARD TABLE OF ROIUX6_WY_STAXHST_TC_0300,
      WA_ROIUX6_WY_STAXHST_TC_0300 TYPE ROIUX6_WY_STAXHST_TC_0300,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIUX6_WY_STAXHST_TC_0300> TYPE ROIUX6_WY_STAXHST_TC_0300.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIUX6_WY_STAXHST_TC_0300.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIUX6_WY_STAXHST_TC_0300
  INTO TABLE IT_ROIUX6_WY_STAXHST_TC_0300.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIUX6_WY_STAXHST_TC_0300
*  INTO TABLE @DATA(IT_ROIUX6_WY_STAXHST_TC_03002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIUX6_WY_STAXHST_TC_0300 INDEX 1 INTO DATA(WA_ROIUX6_WY_STAXHST_TC_03002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIUX6_WY_STAXHST_TC_0300 ASSIGNING <ROIUX6_WY_STAXHST_TC_0300>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIUX6_WY_STAXHST_TC_0300>-MANDT = 1.
<ROIUX6_WY_STAXHST_TC_0300>-BUKRS = 1.
<ROIUX6_WY_STAXHST_TC_0300>-SALES_DT = 1.
<ROIUX6_WY_STAXHST_TC_0300>-PDCD = 1.
<ROIUX6_WY_STAXHST_TC_0300>-WL_NO = 1.
ENDLOOP.

LOOP AT IT_ROIUX6_WY_STAXHST_TC_0300 INTO WA_ROIUX6_WY_STAXHST_TC_0300.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIUX6_WY_STAXHST_TC_0300-WC_NO, sy-vline,
WA_ROIUX6_WY_STAXHST_TC_0300-MP_NO, sy-vline,
WA_ROIUX6_WY_STAXHST_TC_0300-VNAME, sy-vline,
WA_ROIUX6_WY_STAXHST_TC_0300-DOI_NO, sy-vline,
WA_ROIUX6_WY_STAXHST_TC_0300-DN_NO, sy-vline,
WA_ROIUX6_WY_STAXHST_TC_0300-CT_NO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIUX6_WY_STAXHST_TC_0300 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIUX6_WY_STAXHST_TC_0300 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIUX6_WY_STAXHST_TC_0300 INTO WA_ROIUX6_WY_STAXHST_TC_0300. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field WL_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUX6_WY_STAXHST_TC_0300-WL_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX6_WY_STAXHST_TC_0300-WL_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WC_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUX6_WY_STAXHST_TC_0300-WC_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX6_WY_STAXHST_TC_0300-WC_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUX6_WY_STAXHST_TC_0300-MP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX6_WY_STAXHST_TC_0300-MP_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUX6_WY_STAXHST_TC_0300-VNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX6_WY_STAXHST_TC_0300-VNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOI_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUX6_WY_STAXHST_TC_0300-DOI_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX6_WY_STAXHST_TC_0300-DOI_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DN_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUX6_WY_STAXHST_TC_0300-DN_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX6_WY_STAXHST_TC_0300-DN_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CT_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUX6_WY_STAXHST_TC_0300-CT_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX6_WY_STAXHST_TC_0300-CT_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field UNIT_VNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUX6_WY_STAXHST_TC_0300-UNIT_VNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX6_WY_STAXHST_TC_0300-UNIT_VNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIUX6_WY_STAXHST_TC_0300-UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX6_WY_STAXHST_TC_0300-UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOC_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUX6_WY_STAXHST_TC_0300-DOC_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX6_WY_STAXHST_TC_0300-DOC_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field DOC_YEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_ROIUX6_WY_STAXHST_TC_0300-DOC_YEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX6_WY_STAXHST_TC_0300-DOC_YEAR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIUX6_WY_STAXHST_TC_0300_STR,
MANDT TYPE STRING,
BUKRS TYPE STRING,
SALES_DT TYPE STRING,
PDCD TYPE STRING,
WL_NO TYPE STRING,
WC_NO TYPE STRING,
MP_NO TYPE STRING,
VNAME TYPE STRING,
DOI_NO TYPE STRING,
DN_NO TYPE STRING,
CT_NO TYPE STRING,
VL_TYPE_CD TYPE STRING,
TAX_CLS TYPE STRING,
REV_BOOK_ADJ_IND TYPE STRING,
FORM_TYPE TYPE STRING,
UNIT_VNAME TYPE STRING,
PAY_FL TYPE STRING,
RPT_FL TYPE STRING,
UOM TYPE STRING,
GROSS_VOL TYPE STRING,
GROSS_VAL TYPE STRING,
TAX_VAL TYPE STRING,
EXEMPT_VAL_01 TYPE STRING,
EXEMPT_VAL_02 TYPE STRING,
EXEMPT_VAL_03 TYPE STRING,
EXEMPT_VAL_04 TYPE STRING,
EXEMPT_VAL_05 TYPE STRING,
MKT_COST_01 TYPE STRING,
MKT_COST_02 TYPE STRING,
MKT_COST_03 TYPE STRING,
MKT_COST_04 TYPE STRING,
MKT_COST_05 TYPE STRING,
MKT_COST_06 TYPE STRING,
MKT_COST_07 TYPE STRING,
MKT_COST_08 TYPE STRING,
MKT_COST_09 TYPE STRING,
MKT_COST_10 TYPE STRING,
MKT_COST_REIMB TYPE STRING,
SV_TAX_AMT TYPE STRING,
SA_TAX_AMT TYPE STRING,
AV_TAX_AMT TYPE STRING,
XX_TAX_AMT TYPE STRING,
PREV_TAX_PAID TYPE STRING,
TAX_REIMB TYPE STRING,
WET_LESS_RES TYPE STRING,
BLPS_GROSS_VOL TYPE STRING,
BLPS_GROSS_VAL TYPE STRING,
RET_LSE_PC TYPE STRING,
PLANT_PROC_ALLOW TYPE STRING,
COUNTY TYPE STRING,
API_WELL_NUMBER TYPE STRING,
SIDE_TRACK_NO TYPE STRING,
RESERVOIR TYPE STRING,
RPT_GRP_NO TYPE STRING,
FIELD_NAME TYPE STRING,
LEASE_UNIT_NAME TYPE STRING,
OPERATED_FLAG TYPE STRING,
TAX_DISTRICT TYPE STRING,
GAS_PLANT_NAME TYPE STRING,
MASTER_LEVEL TYPE STRING,
OPERATOR_ID TYPE STRING,
RATE_CODE TYPE STRING,
OGIND TYPE STRING,
DOC_NO TYPE STRING,
DOC_YEAR TYPE STRING,
OPTION1 TYPE STRING,
OPTION2 TYPE STRING,
OPTION3 TYPE STRING,
OIU_CRUSER TYPE STRING,
OIU_TIMESTAMP TYPE STRING,
SEL TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIUX6_WY_STAXHST_TC_0300_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-MANDT sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-BUKRS sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-SALES_DT sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-PDCD sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-WL_NO sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-WC_NO sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-MP_NO sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-VNAME sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-DOI_NO sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-DN_NO sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-CT_NO sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-VL_TYPE_CD sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-TAX_CLS sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-REV_BOOK_ADJ_IND sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-FORM_TYPE sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-UNIT_VNAME sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-PAY_FL sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-RPT_FL sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-UOM sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-GROSS_VOL sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-GROSS_VAL sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-TAX_VAL sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-EXEMPT_VAL_01 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-EXEMPT_VAL_02 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-EXEMPT_VAL_03 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-EXEMPT_VAL_04 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-EXEMPT_VAL_05 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-MKT_COST_01 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-MKT_COST_02 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-MKT_COST_03 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-MKT_COST_04 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-MKT_COST_05 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-MKT_COST_06 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-MKT_COST_07 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-MKT_COST_08 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-MKT_COST_09 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-MKT_COST_10 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-MKT_COST_REIMB sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-SV_TAX_AMT sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-SA_TAX_AMT sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-AV_TAX_AMT sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-XX_TAX_AMT sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-PREV_TAX_PAID sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-TAX_REIMB sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-WET_LESS_RES sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-BLPS_GROSS_VOL sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-BLPS_GROSS_VAL sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-RET_LSE_PC sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-PLANT_PROC_ALLOW sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-COUNTY sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-API_WELL_NUMBER sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-SIDE_TRACK_NO sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-RESERVOIR sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-RPT_GRP_NO sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-FIELD_NAME sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-LEASE_UNIT_NAME sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-OPERATED_FLAG sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-TAX_DISTRICT sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-GAS_PLANT_NAME sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-MASTER_LEVEL sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-OPERATOR_ID sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-RATE_CODE sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-OGIND sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-DOC_NO sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-DOC_YEAR sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-OPTION1 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-OPTION2 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-OPTION3 sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-OIU_CRUSER sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-OIU_TIMESTAMP sy-vline
WA_ROIUX6_WY_STAXHST_TC_0300_STR-SEL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.