ABAP Select data from SAP table ROIUX5_OK_RPDT_TC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIUX5_OK_RPDT_TC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIUX5_OK_RPDT_TC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIUX5_OK_RPDT_TC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIUX5_OK_RPDT_TC TYPE STANDARD TABLE OF ROIUX5_OK_RPDT_TC,
      WA_ROIUX5_OK_RPDT_TC TYPE ROIUX5_OK_RPDT_TC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIUX5_OK_RPDT_TC> TYPE ROIUX5_OK_RPDT_TC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIUX5_OK_RPDT_TC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIUX5_OK_RPDT_TC
  INTO TABLE IT_ROIUX5_OK_RPDT_TC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIUX5_OK_RPDT_TC
*  INTO TABLE @DATA(IT_ROIUX5_OK_RPDT_TC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIUX5_OK_RPDT_TC INDEX 1 INTO DATA(WA_ROIUX5_OK_RPDT_TC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIUX5_OK_RPDT_TC ASSIGNING <ROIUX5_OK_RPDT_TC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIUX5_OK_RPDT_TC>-MANDT = 1.
<ROIUX5_OK_RPDT_TC>-RUN_ID = 1.
<ROIUX5_OK_RPDT_TC>-TAXPAYER_NUMBER = 1.
<ROIUX5_OK_RPDT_TC>-PRODUCTION_DATE = 1.
<ROIUX5_OK_RPDT_TC>-OK_PRODUCT_CODE = 1.
ENDLOOP.

LOOP AT IT_ROIUX5_OK_RPDT_TC INTO WA_ROIUX5_OK_RPDT_TC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIUX5_OK_RPDT_TC-COUNTY, sy-vline,
WA_ROIUX5_OK_RPDT_TC-PROD_PURC_IND, sy-vline,
WA_ROIUX5_OK_RPDT_TC-PUN, sy-vline,
WA_ROIUX5_OK_RPDT_TC-PROD_PURCH_NO, sy-vline,
WA_ROIUX5_OK_RPDT_TC-GAS_CODE, sy-vline,
WA_ROIUX5_OK_RPDT_TC-TIER_CATEGORY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIUX5_OK_RPDT_TC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIUX5_OK_RPDT_TC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIUX5_OK_RPDT_TC INTO WA_ROIUX5_OK_RPDT_TC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIUX5_OK_RPDT_TC_STR,
MANDT TYPE STRING,
RUN_ID TYPE STRING,
TAXPAYER_NUMBER TYPE STRING,
PRODUCTION_DATE TYPE STRING,
OK_PRODUCT_CODE TYPE STRING,
COUNTY TYPE STRING,
PROD_PURC_IND TYPE STRING,
PUN TYPE STRING,
PROD_PURCH_NO TYPE STRING,
GAS_CODE TYPE STRING,
TIER_CATEGORY TYPE STRING,
OIL_CLASS TYPE STRING,
NGPA_CD TYPE STRING,
REV_BOOK_ADJ_IND TYPE STRING,
GROSS_VOL TYPE STRING,
GROSS_VAL TYPE STRING,
BTU TYPE STRING,
GRAVITY TYPE STRING,
TAX_REIMB TYPE STRING,
EXEMPT_CODE_1 TYPE STRING,
EXE_DEC_EQUIV_1 TYPE STRING,
EXE_ENTTYPE1_VOL TYPE STRING,
EXE_ENTTYPE1_VAL TYPE STRING,
EXEMPT_CODE_2 TYPE STRING,
EXE_DEC_EQUIV_2 TYPE STRING,
EXE_ENTTYPE2_VOL TYPE STRING,
EXE_ENTTYPE2_VAL TYPE STRING,
EXEMPT_CODE_3 TYPE STRING,
EXE_DEC_EQUIV_3 TYPE STRING,
EXE_ENTTYPE3_VOL TYPE STRING,
EXE_ENTTYPE3_VAL TYPE STRING,
EXEMPT_CODE_4 TYPE STRING,
EXE_DEC_EQUIV_4 TYPE STRING,
EXE_ENTTYPE4_VOL TYPE STRING,
EXE_ENTTYPE4_VAL TYPE STRING,
EXEMPT_CODE_5 TYPE STRING,
EXE_DEC_EQUIV_5 TYPE STRING,
EXE_ENTTYPE5_VOL TYPE STRING,
EXE_ENTTYPE5_VAL TYPE STRING,
EXEMPT_09_VAL TYPE STRING,
TAX_VOL TYPE STRING,
TAX_VAL TYPE STRING,
GP_TAX_AMT TYPE STRING,
PE_TAX_AMT TYPE STRING,
SEC_GEO_DESC TYPE STRING,
TAXPAYER_NAME TYPE STRING,
FEIN_SSN TYPE STRING,
MULTI_COUNTIES TYPE STRING,
OIU_CRUSER TYPE STRING,
OIU_TIMESTAMP TYPE STRING,
SEL TYPE STRING,
GROSS_VAL_DELTA TYPE STRING,
GP_TAX_AMT_DELTA TYPE STRING,
PE_TAX_AMT_DELTA TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIUX5_OK_RPDT_TC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-MANDT sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-RUN_ID sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-TAXPAYER_NUMBER sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-PRODUCTION_DATE sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-OK_PRODUCT_CODE sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-COUNTY sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-PROD_PURC_IND sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-PUN sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-PROD_PURCH_NO sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-GAS_CODE sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-TIER_CATEGORY sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-OIL_CLASS sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-NGPA_CD sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-REV_BOOK_ADJ_IND sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-GROSS_VOL sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-GROSS_VAL sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-BTU sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-GRAVITY sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-TAX_REIMB sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXEMPT_CODE_1 sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXE_DEC_EQUIV_1 sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXE_ENTTYPE1_VOL sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXE_ENTTYPE1_VAL sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXEMPT_CODE_2 sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXE_DEC_EQUIV_2 sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXE_ENTTYPE2_VOL sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXE_ENTTYPE2_VAL sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXEMPT_CODE_3 sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXE_DEC_EQUIV_3 sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXE_ENTTYPE3_VOL sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXE_ENTTYPE3_VAL sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXEMPT_CODE_4 sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXE_DEC_EQUIV_4 sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXE_ENTTYPE4_VOL sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXE_ENTTYPE4_VAL sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXEMPT_CODE_5 sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXE_DEC_EQUIV_5 sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXE_ENTTYPE5_VOL sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXE_ENTTYPE5_VAL sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-EXEMPT_09_VAL sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-TAX_VOL sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-TAX_VAL sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-GP_TAX_AMT sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-PE_TAX_AMT sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-SEC_GEO_DESC sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-TAXPAYER_NAME sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-FEIN_SSN sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-MULTI_COUNTIES sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-OIU_CRUSER sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-OIU_TIMESTAMP sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-SEL sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-GROSS_VAL_DELTA sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-GP_TAX_AMT_DELTA sy-vline
WA_ROIUX5_OK_RPDT_TC_STR-PE_TAX_AMT_DELTA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.