ABAP Select data from SAP table ROIUX1_RPTINFO_LC_DET into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIUX1_RPTINFO_LC_DET table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIUX1_RPTINFO_LC_DET. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIUX1_RPTINFO_LC_DET table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIUX1_RPTINFO_LC_DET TYPE STANDARD TABLE OF ROIUX1_RPTINFO_LC_DET,
      WA_ROIUX1_RPTINFO_LC_DET TYPE ROIUX1_RPTINFO_LC_DET,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIUX1_RPTINFO_LC_DET> TYPE ROIUX1_RPTINFO_LC_DET.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIUX1_RPTINFO_LC_DET.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIUX1_RPTINFO_LC_DET
  INTO TABLE IT_ROIUX1_RPTINFO_LC_DET.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIUX1_RPTINFO_LC_DET
*  INTO TABLE @DATA(IT_ROIUX1_RPTINFO_LC_DET2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIUX1_RPTINFO_LC_DET INDEX 1 INTO DATA(WA_ROIUX1_RPTINFO_LC_DET2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIUX1_RPTINFO_LC_DET ASSIGNING <ROIUX1_RPTINFO_LC_DET>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIUX1_RPTINFO_LC_DET>-MANDT = 1.
<ROIUX1_RPTINFO_LC_DET>-RPT_YYYYMM = 1.
<ROIUX1_RPTINFO_LC_DET>-RSG = 1.
<ROIUX1_RPTINFO_LC_DET>-AGENCY = 1.
<ROIUX1_RPTINFO_LC_DET>-OGIND = 1.
ENDLOOP.

LOOP AT IT_ROIUX1_RPTINFO_LC_DET INTO WA_ROIUX1_RPTINFO_LC_DET.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIUX1_RPTINFO_LC_DET-SALES_YYYYMM, sy-vline,
WA_ROIUX1_RPTINFO_LC_DET-PUID, sy-vline,
WA_ROIUX1_RPTINFO_LC_DET-AGENCY_VOL_TYPE, sy-vline,
WA_ROIUX1_RPTINFO_LC_DET-AGENCY_TAX_CODE, sy-vline,
WA_ROIUX1_RPTINFO_LC_DET-PDIND, sy-vline,
WA_ROIUX1_RPTINFO_LC_DET-AFFL_COMP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIUX1_RPTINFO_LC_DET you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIUX1_RPTINFO_LC_DET TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIUX1_RPTINFO_LC_DET INTO WA_ROIUX1_RPTINFO_LC_DET. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field UNIT_VNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUX1_RPTINFO_LC_DET-UNIT_VNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX1_RPTINFO_LC_DET-UNIT_VNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ACTL_GR_VL_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIUX1_RPTINFO_LC_DET-ACTL_GR_VL_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX1_RPTINFO_LC_DET-ACTL_GR_VL_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ACTL_WLR_VL_AM_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIUX1_RPTINFO_LC_DET-ACTL_WLR_VL_AM_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX1_RPTINFO_LC_DET-ACTL_WLR_VL_AM_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ACTL_ENERGY_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIUX1_RPTINFO_LC_DET-ACTL_ENERGY_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX1_RPTINFO_LC_DET-ACTL_ENERGY_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PU_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUX1_RPTINFO_LC_DET-PU_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX1_RPTINFO_LC_DET-PU_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUX1_RPTINFO_LC_DET-VNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX1_RPTINFO_LC_DET-VNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOI_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUX1_RPTINFO_LC_DET-DOI_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX1_RPTINFO_LC_DET-DOI_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUX1_RPTINFO_LC_DET-MP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX1_RPTINFO_LC_DET-MP_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WL_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUX1_RPTINFO_LC_DET-WL_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX1_RPTINFO_LC_DET-WL_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WC_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUX1_RPTINFO_LC_DET-WC_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUX1_RPTINFO_LC_DET-WC_NO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIUX1_RPTINFO_LC_DET_STR,
MANDT TYPE STRING,
RPT_YYYYMM TYPE STRING,
RSG TYPE STRING,
AGENCY TYPE STRING,
OGIND TYPE STRING,
SALES_YYYYMM TYPE STRING,
PUID TYPE STRING,
AGENCY_VOL_TYPE TYPE STRING,
AGENCY_TAX_CODE TYPE STRING,
PDIND TYPE STRING,
AFFL_COMP TYPE STRING,
UNIT_VNAME TYPE STRING,
SEC_GEO_LOC TYPE STRING,
GRV_AM TYPE STRING,
ACTL_TXVL TYPE STRING,
ACTL_OVRD_TAXVL TYPE STRING,
ACTL_GR_VL TYPE STRING,
TAX_FREE_05_VL TYPE STRING,
BLPS_GR_VL TYPE STRING,
ACTL_GR_VL_U TYPE STRING,
ACTL_WLR_VL_AM TYPE STRING,
TAX_FREE_05_WLR TYPE STRING,
ACTL_WLR_VL_AM_U TYPE STRING,
ACTL_ENERGY TYPE STRING,
ACTL_ENERGY_U TYPE STRING,
FX_MCD TYPE STRING,
ACTL_GR_VAL_AM TYPE STRING,
TAX_FREE_05_VAL TYPE STRING,
BLPS_GR_VAL TYPE STRING,
ST_TAX_PROC_ALLW TYPE STRING,
ACTL_TXVAL TYPE STRING,
ACTL_OVRD_TAXVAL TYPE STRING,
ACTL_ST_TAX_AM TYPE STRING,
ACTL_ST_TAX_RMB TYPE STRING,
GR_VAL_CURR TYPE STRING,
USERNAME TYPE STRING,
TIMESTAMP TYPE STRING,
PU_NO TYPE STRING,
UPLOAD TYPE STRING,
MTA_MKCT_INT01 TYPE STRING,
MTA_MKCT_INT02 TYPE STRING,
MTA_MKCT_INT03 TYPE STRING,
MTA_MKCT_INT04 TYPE STRING,
MTA_MKCT_INT05 TYPE STRING,
MTA_MKCT_INT06 TYPE STRING,
MTA_MKCT_INT07 TYPE STRING,
MTA_MKCT_INT08 TYPE STRING,
MTA_MKCT_INT09 TYPE STRING,
MTA_MKCT_INT10 TYPE STRING,
MTA_MKCT_EXT01 TYPE STRING,
MTA_MKCT_EXT02 TYPE STRING,
MTA_MKCT_EXT03 TYPE STRING,
MTA_MKCT_EXT04 TYPE STRING,
MTA_MKCT_EXT05 TYPE STRING,
MTA_MKCT_EXT06 TYPE STRING,
MTA_MKCT_EXT07 TYPE STRING,
MTA_MKCT_EXT08 TYPE STRING,
MTA_MKCT_EXT09 TYPE STRING,
MTA_MKCT_EXT10 TYPE STRING,
MTA_MCR_EXT01 TYPE STRING,
MTA_MCR_EXT02 TYPE STRING,
MTA_MCR_EXT03 TYPE STRING,
MTA_MCR_EXT04 TYPE STRING,
MTA_MCR_EXT05 TYPE STRING,
MTA_MCR_EXT06 TYPE STRING,
MTA_MCR_EXT07 TYPE STRING,
MTA_MCR_EXT08 TYPE STRING,
MTA_MCR_EXT09 TYPE STRING,
MTA_MCR_EXT10 TYPE STRING,
EXMP_VL01 TYPE STRING,
EXMP_VL02 TYPE STRING,
EXMP_VL03 TYPE STRING,
EXMP_VL04 TYPE STRING,
EXMP_VL05 TYPE STRING,
EXMP_VAL01 TYPE STRING,
EXMP_VAL02 TYPE STRING,
EXMP_VAL03 TYPE STRING,
EXMP_VAL04 TYPE STRING,
EXMP_VAL05 TYPE STRING,
BUKRS TYPE STRING,
VNAME TYPE STRING,
DOI_NO TYPE STRING,
MP_NO TYPE STRING,
WL_NO TYPE STRING,
WC_NO TYPE STRING,
TRACT_PF TYPE STRING,
LEASE_SHARE TYPE STRING,
EX_ALLOC_FAC TYPE STRING,
REALLOC_EXEMPT TYPE STRING,
LC_IND TYPE STRING,
TAXH_SYSNO TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIUX1_RPTINFO_LC_DET_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MANDT sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-RPT_YYYYMM sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-RSG sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-AGENCY sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-OGIND sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-SALES_YYYYMM sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-PUID sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-AGENCY_VOL_TYPE sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-AGENCY_TAX_CODE sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-PDIND sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-AFFL_COMP sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-UNIT_VNAME sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-SEC_GEO_LOC sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-GRV_AM sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-ACTL_TXVL sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-ACTL_OVRD_TAXVL sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-ACTL_GR_VL sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-TAX_FREE_05_VL sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-BLPS_GR_VL sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-ACTL_GR_VL_U sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-ACTL_WLR_VL_AM sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-TAX_FREE_05_WLR sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-ACTL_WLR_VL_AM_U sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-ACTL_ENERGY sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-ACTL_ENERGY_U sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-FX_MCD sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-ACTL_GR_VAL_AM sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-TAX_FREE_05_VAL sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-BLPS_GR_VAL sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-ST_TAX_PROC_ALLW sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-ACTL_TXVAL sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-ACTL_OVRD_TAXVAL sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-ACTL_ST_TAX_AM sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-ACTL_ST_TAX_RMB sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-GR_VAL_CURR sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-USERNAME sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-TIMESTAMP sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-PU_NO sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-UPLOAD sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_INT01 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_INT02 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_INT03 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_INT04 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_INT05 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_INT06 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_INT07 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_INT08 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_INT09 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_INT10 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_EXT01 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_EXT02 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_EXT03 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_EXT04 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_EXT05 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_EXT06 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_EXT07 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_EXT08 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_EXT09 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MKCT_EXT10 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MCR_EXT01 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MCR_EXT02 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MCR_EXT03 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MCR_EXT04 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MCR_EXT05 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MCR_EXT06 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MCR_EXT07 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MCR_EXT08 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MCR_EXT09 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MTA_MCR_EXT10 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-EXMP_VL01 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-EXMP_VL02 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-EXMP_VL03 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-EXMP_VL04 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-EXMP_VL05 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-EXMP_VAL01 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-EXMP_VAL02 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-EXMP_VAL03 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-EXMP_VAL04 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-EXMP_VAL05 sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-BUKRS sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-VNAME sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-DOI_NO sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-MP_NO sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-WL_NO sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-WC_NO sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-TRACT_PF sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-LEASE_SHARE sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-EX_ALLOC_FAC sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-REALLOC_EXEMPT sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-LC_IND sy-vline
WA_ROIUX1_RPTINFO_LC_DET_STR-TAXH_SYSNO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.