ABAP Select data from SAP table ROIUVL_RPTD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIUVL_RPTD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIUVL_RPTD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIUVL_RPTD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIUVL_RPTD TYPE STANDARD TABLE OF ROIUVL_RPTD,
      WA_ROIUVL_RPTD TYPE ROIUVL_RPTD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIUVL_RPTD> TYPE ROIUVL_RPTD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIUVL_RPTD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIUVL_RPTD
  INTO TABLE IT_ROIUVL_RPTD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIUVL_RPTD
*  INTO TABLE @DATA(IT_ROIUVL_RPTD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIUVL_RPTD INDEX 1 INTO DATA(WA_ROIUVL_RPTD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIUVL_RPTD ASSIGNING <ROIUVL_RPTD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIUVL_RPTD>-RPTH_NO = 1.
<ROIUVL_RPTD>-RUN_TKT_NO = 1.
<ROIUVL_RPTD>-WI_INT_TYPE_CD = 1.
<ROIUVL_RPTD>-WI_OWN_ISQ_NO = 1.
<ROIUVL_RPTD>-EFF_FROM_DT = 1.
ENDLOOP.

LOOP AT IT_ROIUVL_RPTD INTO WA_ROIUVL_RPTD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIUVL_RPTD-EFF_TO_DT, sy-vline,
WA_ROIUVL_RPTD-VL_TYPE_CD, sy-vline,
WA_ROIUVL_RPTD-TRNSP_NO, sy-vline,
WA_ROIUVL_RPTD-TRNSP_REF_NO, sy-vline,
WA_ROIUVL_RPTD-DENSITY, sy-vline,
WA_ROIUVL_RPTD-DENSITY_U, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIUVL_RPTD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIUVL_RPTD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIUVL_RPTD INTO WA_ROIUVL_RPTD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field WI_OWN_ISQ_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUVL_RPTD-WI_OWN_ISQ_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUVL_RPTD-WI_OWN_ISQ_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRNSP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUVL_RPTD-TRNSP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUVL_RPTD-TRNSP_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DENSITY_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIUVL_RPTD-DENSITY_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUVL_RPTD-DENSITY_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLUME_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIUVL_RPTD-VOLUME_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUVL_RPTD-VOLUME_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ENERGY_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIUVL_RPTD-ENERGY_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUVL_RPTD-ENERGY_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field HEAT_VALUE_FCT_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIUVL_RPTD-HEAT_VALUE_FCT_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUVL_RPTD-HEAT_VALUE_FCT_U.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIUVL_RPTD_STR,
RPTH_NO TYPE STRING,
RUN_TKT_NO TYPE STRING,
WI_INT_TYPE_CD TYPE STRING,
WI_OWN_ISQ_NO TYPE STRING,
EFF_FROM_DT TYPE STRING,
EFF_TO_DT TYPE STRING,
VL_TYPE_CD TYPE STRING,
TRNSP_NO TYPE STRING,
TRNSP_REF_NO TYPE STRING,
DENSITY TYPE STRING,
DENSITY_U TYPE STRING,
ACTL_GR_VL TYPE STRING,
ENTL_GR_VL TYPE STRING,
VOLUME_AM TYPE STRING,
VOLUME_UNIT TYPE STRING,
PC_AMT TYPE STRING,
PC_CURR TYPE STRING,
ACTL_ENERGY TYPE STRING,
ENTL_ENERGY TYPE STRING,
ENERGY_U TYPE STRING,
ACTL_GR_VAL_AM TYPE STRING,
ENTL_GR_VAL_AM TYPE STRING,
ACT_HEAT_VAL_FCT TYPE STRING,
HEAT_VALUE_FCT_U TYPE STRING,
GROSS_VAL_AM TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIUVL_RPTD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIUVL_RPTD_STR-RPTH_NO sy-vline
WA_ROIUVL_RPTD_STR-RUN_TKT_NO sy-vline
WA_ROIUVL_RPTD_STR-WI_INT_TYPE_CD sy-vline
WA_ROIUVL_RPTD_STR-WI_OWN_ISQ_NO sy-vline
WA_ROIUVL_RPTD_STR-EFF_FROM_DT sy-vline
WA_ROIUVL_RPTD_STR-EFF_TO_DT sy-vline
WA_ROIUVL_RPTD_STR-VL_TYPE_CD sy-vline
WA_ROIUVL_RPTD_STR-TRNSP_NO sy-vline
WA_ROIUVL_RPTD_STR-TRNSP_REF_NO sy-vline
WA_ROIUVL_RPTD_STR-DENSITY sy-vline
WA_ROIUVL_RPTD_STR-DENSITY_U sy-vline
WA_ROIUVL_RPTD_STR-ACTL_GR_VL sy-vline
WA_ROIUVL_RPTD_STR-ENTL_GR_VL sy-vline
WA_ROIUVL_RPTD_STR-VOLUME_AM sy-vline
WA_ROIUVL_RPTD_STR-VOLUME_UNIT sy-vline
WA_ROIUVL_RPTD_STR-PC_AMT sy-vline
WA_ROIUVL_RPTD_STR-PC_CURR sy-vline
WA_ROIUVL_RPTD_STR-ACTL_ENERGY sy-vline
WA_ROIUVL_RPTD_STR-ENTL_ENERGY sy-vline
WA_ROIUVL_RPTD_STR-ENERGY_U sy-vline
WA_ROIUVL_RPTD_STR-ACTL_GR_VAL_AM sy-vline
WA_ROIUVL_RPTD_STR-ENTL_GR_VAL_AM sy-vline
WA_ROIUVL_RPTD_STR-ACT_HEAT_VAL_FCT sy-vline
WA_ROIUVL_RPTD_STR-HEAT_VALUE_FCT_U sy-vline
WA_ROIUVL_RPTD_STR-GROSS_VAL_AM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.