ABAP Select data from SAP table ROIURV_T5_MRKT_AMT_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIURV_T5_MRKT_AMT_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIURV_T5_MRKT_AMT_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIURV_T5_MRKT_AMT_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIURV_T5_MRKT_AMT_DATA TYPE STANDARD TABLE OF ROIURV_T5_MRKT_AMT_DATA,
      WA_ROIURV_T5_MRKT_AMT_DATA TYPE ROIURV_T5_MRKT_AMT_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIURV_T5_MRKT_AMT_DATA> TYPE ROIURV_T5_MRKT_AMT_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIURV_T5_MRKT_AMT_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIURV_T5_MRKT_AMT_DATA
  INTO TABLE IT_ROIURV_T5_MRKT_AMT_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIURV_T5_MRKT_AMT_DATA
*  INTO TABLE @DATA(IT_ROIURV_T5_MRKT_AMT_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIURV_T5_MRKT_AMT_DATA INDEX 1 INTO DATA(WA_ROIURV_T5_MRKT_AMT_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIURV_T5_MRKT_AMT_DATA ASSIGNING <ROIURV_T5_MRKT_AMT_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIURV_T5_MRKT_AMT_DATA>-MR_TYPE_CD = 1.
<ROIURV_T5_MRKT_AMT_DATA>-A_ALT_CT_NO = 1.
<ROIURV_T5_MRKT_AMT_DATA>-A_INT_PR_NO = 1.
<ROIURV_T5_MRKT_AMT_DATA>-A_INT_DOI_NO = 1.
<ROIURV_T5_MRKT_AMT_DATA>-A_INT_BILL_CD = 1.
ENDLOOP.

LOOP AT IT_ROIURV_T5_MRKT_AMT_DATA INTO WA_ROIURV_T5_MRKT_AMT_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIURV_T5_MRKT_AMT_DATA-A_EXT_PR_NO, sy-vline,
WA_ROIURV_T5_MRKT_AMT_DATA-A_EXT_DOI_NO, sy-vline,
WA_ROIURV_T5_MRKT_AMT_DATA-A_EXT_BILL_CD, sy-vline,
WA_ROIURV_T5_MRKT_AMT_DATA-A_EXT_TRNSP_NO, sy-vline,
WA_ROIURV_T5_MRKT_AMT_DATA-A_EXT_TRNSP_SEQ_NO, sy-vline,
WA_ROIURV_T5_MRKT_AMT_DATA-A_EXT_TRNSP_CT_NO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIURV_T5_MRKT_AMT_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIURV_T5_MRKT_AMT_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIURV_T5_MRKT_AMT_DATA INTO WA_ROIURV_T5_MRKT_AMT_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIURV_T5_MRKT_AMT_DATA_STR,
MR_TYPE_CD TYPE STRING,
A_ALT_CT_NO TYPE STRING,
A_INT_PR_NO TYPE STRING,
A_INT_DOI_NO TYPE STRING,
A_INT_BILL_CD TYPE STRING,
A_EXT_PR_NO TYPE STRING,
A_EXT_DOI_NO TYPE STRING,
A_EXT_BILL_CD TYPE STRING,
A_EXT_TRNSP_NO TYPE STRING,
A_EXT_TRNSP_SEQ_NO TYPE STRING,
A_EXT_TRNSP_CT_NO TYPE STRING,
A_EXT_RECOUP_FL TYPE STRING,
A_INT_MR_CT_AM TYPE STRING,
A_FACILITY_INC_AM TYPE STRING,
A_EXT_MR_CT_AM TYPE STRING,
A_EXT_AFF_RECOUP_AM TYPE STRING,
A_EXT_NON_AFF_RECOUP_AM TYPE STRING,
A_EXT_MR_RM_AM TYPE STRING,
A_INT_MR_DED_AM TYPE STRING,
A_EXT_MR_DED_AM TYPE STRING,
A_INT_MR_CT_TOT TYPE STRING,
A_EXT_MR_CT_TOT TYPE STRING,
A_EXT_MR_RM_TOT TYPE STRING,
E_INT_MR_CT_AM TYPE STRING,
E_EXT_MR_CT_AM TYPE STRING,
E_EXT_MR_RM_AM TYPE STRING,
E_INT_MR_DED_AM TYPE STRING,
E_EXT_MR_DED_AM TYPE STRING,
S_INT_MR_CT_AM TYPE STRING,
S_EXT_MR_CT_AM TYPE STRING,
S_EXT_MR_RM_AM TYPE STRING,
MR_CT_U TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIURV_T5_MRKT_AMT_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-MR_TYPE_CD sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_ALT_CT_NO sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_INT_PR_NO sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_INT_DOI_NO sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_INT_BILL_CD sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_EXT_PR_NO sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_EXT_DOI_NO sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_EXT_BILL_CD sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_EXT_TRNSP_NO sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_EXT_TRNSP_SEQ_NO sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_EXT_TRNSP_CT_NO sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_EXT_RECOUP_FL sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_INT_MR_CT_AM sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_FACILITY_INC_AM sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_EXT_MR_CT_AM sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_EXT_AFF_RECOUP_AM sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_EXT_NON_AFF_RECOUP_AM sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_EXT_MR_RM_AM sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_INT_MR_DED_AM sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_EXT_MR_DED_AM sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_INT_MR_CT_TOT sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_EXT_MR_CT_TOT sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-A_EXT_MR_RM_TOT sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-E_INT_MR_CT_AM sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-E_EXT_MR_CT_AM sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-E_EXT_MR_RM_AM sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-E_INT_MR_DED_AM sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-E_EXT_MR_DED_AM sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-S_INT_MR_CT_AM sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-S_EXT_MR_CT_AM sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-S_EXT_MR_RM_AM sy-vline
WA_ROIURV_T5_MRKT_AMT_DATA_STR-MR_CT_U sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.