ABAP Select data from SAP table ROIUREP_TX_P1_DETAIL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIUREP_TX_P1_DETAIL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIUREP_TX_P1_DETAIL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIUREP_TX_P1_DETAIL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIUREP_TX_P1_DETAIL TYPE STANDARD TABLE OF ROIUREP_TX_P1_DETAIL,
      WA_ROIUREP_TX_P1_DETAIL TYPE ROIUREP_TX_P1_DETAIL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIUREP_TX_P1_DETAIL> TYPE ROIUREP_TX_P1_DETAIL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIUREP_TX_P1_DETAIL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIUREP_TX_P1_DETAIL
  INTO TABLE IT_ROIUREP_TX_P1_DETAIL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIUREP_TX_P1_DETAIL
*  INTO TABLE @DATA(IT_ROIUREP_TX_P1_DETAIL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIUREP_TX_P1_DETAIL INDEX 1 INTO DATA(WA_ROIUREP_TX_P1_DETAIL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIUREP_TX_P1_DETAIL ASSIGNING <ROIUREP_TX_P1_DETAIL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIUREP_TX_P1_DETAIL>-HEAD_SEQNR = 1.
<ROIUREP_TX_P1_DETAIL>-REC_TYPE = 1.
<ROIUREP_TX_P1_DETAIL>-OPERATOR_NUMBER = 1.
<ROIUREP_TX_P1_DETAIL>-REPORT_TYPE = 1.
<ROIUREP_TX_P1_DETAIL>-DISTRICT = 1.
ENDLOOP.

LOOP AT IT_ROIUREP_TX_P1_DETAIL INTO WA_ROIUREP_TX_P1_DETAIL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIUREP_TX_P1_DETAIL-RECORD_TYPE, sy-vline,
WA_ROIUREP_TX_P1_DETAIL-FILLER1, sy-vline,
WA_ROIUREP_TX_P1_DETAIL-CMGL_PRMT_NO, sy-vline,
WA_ROIUREP_TX_P1_DETAIL-FIELD_NAME, sy-vline,
WA_ROIUREP_TX_P1_DETAIL-FILLER33, sy-vline,
WA_ROIUREP_TX_P1_DETAIL-RRC_OIL_NO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIUREP_TX_P1_DETAIL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIUREP_TX_P1_DETAIL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIUREP_TX_P1_DETAIL INTO WA_ROIUREP_TX_P1_DETAIL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RRC_OIL_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUREP_TX_P1_DETAIL-RRC_OIL_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUREP_TX_P1_DETAIL-RRC_OIL_NO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIUREP_TX_P1_DETAIL_STR,
HEAD_SEQNR TYPE STRING,
REC_TYPE TYPE STRING,
OPERATOR_NUMBER TYPE STRING,
REPORT_TYPE TYPE STRING,
DISTRICT TYPE STRING,
RECORD_TYPE TYPE STRING,
FILLER1 TYPE STRING,
CMGL_PRMT_NO TYPE STRING,
FIELD_NAME TYPE STRING,
FILLER33 TYPE STRING,
RRC_OIL_NO TYPE STRING,
FILLER10 TYPE STRING,
PROD_YEAR TYPE STRING,
PROD_MONTH TYPE STRING,
LEASE_NAME TYPE STRING,
FILLER6 TYPE STRING,
BEGIN_INV TYPE STRING,
OIL_PROD TYPE STRING,
OIL_DISP_PIPELINE TYPE STRING,
OIL_DISP_TRUCK TYPE STRING,
OIL_DISP_TANK TYPE STRING,
OIL_DISP_NET_TANK TYPE STRING,
OIL_DISP_CIRC TYPE STRING,
OIL_DISP_LOST TYPE STRING,
OIL_DISP_SEDMNT TYPE STRING,
OIL_DISP_OTHER_NM TYPE STRING,
OIL_DISP_OTHER_EXP TYPE STRING,
OIL_DISP_SKIM TYPE STRING,
OIL_DISP_SCRUBBER TYPE STRING,
END_INV TYPE STRING,
GAS_PROD TYPE STRING,
GLG_INJECTED TYPE STRING,
GAS_DISP_LSE TYPE STRING,
GAS_DISP_TRMN TYPE STRING,
GAS_DISP_PLANT TYPE STRING,
GAS_DISP_VENTED TYPE STRING,
FILLER2 TYPE STRING,
GAS_DISP_LIFT TYPE STRING,
GAS_DISP_PRESSURE TYPE STRING,
GAS_DISP_CARBON TYPE STRING,
GAS_DISP_UNDERGROUND TYPE STRING,
GENERAL_COMMENTS TYPE STRING,
FILLER9 TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIUREP_TX_P1_DETAIL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-HEAD_SEQNR sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-REC_TYPE sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-OPERATOR_NUMBER sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-REPORT_TYPE sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-DISTRICT sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-RECORD_TYPE sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-FILLER1 sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-CMGL_PRMT_NO sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-FIELD_NAME sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-FILLER33 sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-RRC_OIL_NO sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-FILLER10 sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-PROD_YEAR sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-PROD_MONTH sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-LEASE_NAME sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-FILLER6 sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-BEGIN_INV sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-OIL_PROD sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-OIL_DISP_PIPELINE sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-OIL_DISP_TRUCK sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-OIL_DISP_TANK sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-OIL_DISP_NET_TANK sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-OIL_DISP_CIRC sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-OIL_DISP_LOST sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-OIL_DISP_SEDMNT sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-OIL_DISP_OTHER_NM sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-OIL_DISP_OTHER_EXP sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-OIL_DISP_SKIM sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-OIL_DISP_SCRUBBER sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-END_INV sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-GAS_PROD sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-GLG_INJECTED sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-GAS_DISP_LSE sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-GAS_DISP_TRMN sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-GAS_DISP_PLANT sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-GAS_DISP_VENTED sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-FILLER2 sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-GAS_DISP_LIFT sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-GAS_DISP_PRESSURE sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-GAS_DISP_CARBON sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-GAS_DISP_UNDERGROUND sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-GENERAL_COMMENTS sy-vline
WA_ROIUREP_TX_P1_DETAIL_STR-FILLER9 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.