ABAP Select data from SAP table ROIUREP_CA_110_DISP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIUREP_CA_110_DISP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIUREP_CA_110_DISP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIUREP_CA_110_DISP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIUREP_CA_110_DISP TYPE STANDARD TABLE OF ROIUREP_CA_110_DISP,
      WA_ROIUREP_CA_110_DISP TYPE ROIUREP_CA_110_DISP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIUREP_CA_110_DISP> TYPE ROIUREP_CA_110_DISP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIUREP_CA_110_DISP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIUREP_CA_110_DISP
  INTO TABLE IT_ROIUREP_CA_110_DISP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIUREP_CA_110_DISP
*  INTO TABLE @DATA(IT_ROIUREP_CA_110_DISP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIUREP_CA_110_DISP INDEX 1 INTO DATA(WA_ROIUREP_CA_110_DISP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIUREP_CA_110_DISP ASSIGNING <ROIUREP_CA_110_DISP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIUREP_CA_110_DISP>-HEAD_SEQNR = 1.
<ROIUREP_CA_110_DISP>-REC_TYPE = 1.
<ROIUREP_CA_110_DISP>-OPERATOR_NAME = 1.
<ROIUREP_CA_110_DISP>-OPERATOR_CODE = 1.
<ROIUREP_CA_110_DISP>-REPORT_PERIOD = 1.
ENDLOOP.

LOOP AT IT_ROIUREP_CA_110_DISP INTO WA_ROIUREP_CA_110_DISP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIUREP_CA_110_DISP-DATE_RPT_PREPARED, sy-vline,
WA_ROIUREP_CA_110_DISP-RPT_PREPARED_BY, sy-vline,
WA_ROIUREP_CA_110_DISP-FIELD_NM, sy-vline,
WA_ROIUREP_CA_110_DISP-FIELD_CD, sy-vline,
WA_ROIUREP_CA_110_DISP-DISTRICT, sy-vline,
WA_ROIUREP_CA_110_DISP-DISP_OIL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIUREP_CA_110_DISP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIUREP_CA_110_DISP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIUREP_CA_110_DISP INTO WA_ROIUREP_CA_110_DISP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIUREP_CA_110_DISP_STR,
HEAD_SEQNR TYPE STRING,
REC_TYPE TYPE STRING,
OPERATOR_NAME TYPE STRING,
OPERATOR_CODE TYPE STRING,
REPORT_PERIOD TYPE STRING,
DATE_RPT_PREPARED TYPE STRING,
RPT_PREPARED_BY TYPE STRING,
FIELD_NM TYPE STRING,
FIELD_CD TYPE STRING,
DISTRICT TYPE STRING,
DISP_OIL TYPE STRING,
DISP_GAS TYPE STRING,
GAS_TO_AIR TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIUREP_CA_110_DISP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIUREP_CA_110_DISP_STR-HEAD_SEQNR sy-vline
WA_ROIUREP_CA_110_DISP_STR-REC_TYPE sy-vline
WA_ROIUREP_CA_110_DISP_STR-OPERATOR_NAME sy-vline
WA_ROIUREP_CA_110_DISP_STR-OPERATOR_CODE sy-vline
WA_ROIUREP_CA_110_DISP_STR-REPORT_PERIOD sy-vline
WA_ROIUREP_CA_110_DISP_STR-DATE_RPT_PREPARED sy-vline
WA_ROIUREP_CA_110_DISP_STR-RPT_PREPARED_BY sy-vline
WA_ROIUREP_CA_110_DISP_STR-FIELD_NM sy-vline
WA_ROIUREP_CA_110_DISP_STR-FIELD_CD sy-vline
WA_ROIUREP_CA_110_DISP_STR-DISTRICT sy-vline
WA_ROIUREP_CA_110_DISP_STR-DISP_OIL sy-vline
WA_ROIUREP_CA_110_DISP_STR-DISP_GAS sy-vline
WA_ROIUREP_CA_110_DISP_STR-GAS_TO_AIR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.