ABAP Select data from SAP table ROIUGR_ROYTXNA_NONKEY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIUGR_ROYTXNA_NONKEY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIUGR_ROYTXNA_NONKEY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIUGR_ROYTXNA_NONKEY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIUGR_ROYTXNA_NONKEY TYPE STANDARD TABLE OF ROIUGR_ROYTXNA_NONKEY,
      WA_ROIUGR_ROYTXNA_NONKEY TYPE ROIUGR_ROYTXNA_NONKEY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIUGR_ROYTXNA_NONKEY> TYPE ROIUGR_ROYTXNA_NONKEY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIUGR_ROYTXNA_NONKEY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIUGR_ROYTXNA_NONKEY
  INTO TABLE IT_ROIUGR_ROYTXNA_NONKEY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIUGR_ROYTXNA_NONKEY
*  INTO TABLE @DATA(IT_ROIUGR_ROYTXNA_NONKEY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIUGR_ROYTXNA_NONKEY INDEX 1 INTO DATA(WA_ROIUGR_ROYTXNA_NONKEY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIUGR_ROYTXNA_NONKEY ASSIGNING <ROIUGR_ROYTXNA_NONKEY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIUGR_ROYTXNA_NONKEY>-ALLOC_PERCENT = 1.
<ROIUGR_ROYTXNA_NONKEY>-ENTITY_LINK_GUID = 1.
<ROIUGR_ROYTXNA_NONKEY>-UNIT_VNAME = 1.
<ROIUGR_ROYTXNA_NONKEY>-OPERATED_FL = 1.
<ROIUGR_ROYTXNA_NONKEY>-LAND1 = 1.
ENDLOOP.

LOOP AT IT_ROIUGR_ROYTXNA_NONKEY INTO WA_ROIUGR_ROYTXNA_NONKEY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIUGR_ROYTXNA_NONKEY-REGIO, sy-vline,
WA_ROIUGR_ROYTXNA_NONKEY-PRI_GEO_LOC, sy-vline,
WA_ROIUGR_ROYTXNA_NONKEY-COUNC, sy-vline,
WA_ROIUGR_ROYTXNA_NONKEY-SAKNR, sy-vline,
WA_ROIUGR_ROYTXNA_NONKEY-ENTY_CD, sy-vline,
WA_ROIUGR_ROYTXNA_NONKEY-PAY_CD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIUGR_ROYTXNA_NONKEY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIUGR_ROYTXNA_NONKEY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIUGR_ROYTXNA_NONKEY INTO WA_ROIUGR_ROYTXNA_NONKEY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field UNIT_VNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUGR_ROYTXNA_NONKEY-UNIT_VNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUGR_ROYTXNA_NONKEY-UNIT_VNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SAKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUGR_ROYTXNA_NONKEY-SAKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUGR_ROYTXNA_NONKEY-SAKNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOL_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIUGR_ROYTXNA_NONKEY-VOL_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUGR_ROYTXNA_NONKEY-VOL_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ENERGY_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIUGR_ROYTXNA_NONKEY-ENERGY_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUGR_ROYTXNA_NONKEY-ENERGY_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field HEAT_VAL_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIUGR_ROYTXNA_NONKEY-HEAT_VAL_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUGR_ROYTXNA_NONKEY-HEAT_VAL_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRES_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIUGR_ROYTXNA_NONKEY-PRES_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUGR_ROYTXNA_NONKEY-PRES_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOC_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUGR_ROYTXNA_NONKEY-DOC_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUGR_ROYTXNA_NONKEY-DOC_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field DOC_YEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_ROIUGR_ROYTXNA_NONKEY-DOC_YEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUGR_ROYTXNA_NONKEY-DOC_YEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADDRNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIUGR_ROYTXNA_NONKEY-ADDRNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIUGR_ROYTXNA_NONKEY-ADDRNUMBER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIUGR_ROYTXNA_NONKEY_STR,
ALLOC_PERCENT TYPE STRING,
ENTITY_LINK_GUID TYPE STRING,
UNIT_VNAME TYPE STRING,
OPERATED_FL TYPE STRING,
LAND1 TYPE STRING,
REGIO TYPE STRING,
PRI_GEO_LOC TYPE STRING,
COUNC TYPE STRING,
SAKNR TYPE STRING,
ENTY_CD TYPE STRING,
PAY_CD TYPE STRING,
WAERS TYPE STRING,
VOL_UOM TYPE STRING,
ENERGY_UOM TYPE STRING,
HEAT_VAL_UOM TYPE STRING,
PRES_UOM TYPE STRING,
HEAT_VAL TYPE STRING,
PS_BASE_QY TYPE STRING,
GRAVITY TYPE STRING,
DISB_DECIMAL TYPE STRING,
NRI_DECIMAL TYPE STRING,
DOC_NO TYPE STRING,
DOC_YEAR TYPE STRING,
OPTION1 TYPE STRING,
OPTION2 TYPE STRING,
OPTION3 TYPE STRING,
INTERFACE_FL TYPE STRING,
OOS_FL TYPE STRING,
GROSS_VOL TYPE STRING,
GROSS_ENERGY TYPE STRING,
GROSS_PVR TYPE STRING,
GROSS_PTR TYPE STRING,
NET_VOL TYPE STRING,
OWNER_ENERGY TYPE STRING,
OWN_PVR TYPE STRING,
OWN_PTR TYPE STRING,
GROSS_VAL TYPE STRING,
NET_VAL TYPE STRING,
OWNER_GROSS_VAL TYPE STRING,
PROF_LINK_GUID TYPE STRING,
ADDRNUMBER TYPE STRING,
MASTER_LEVEL TYPE STRING,
MASTER_LINK_GUID TYPE STRING,
PRODUCT_CODE TYPE STRING,
REFERENCE_RUN_ID TYPE STRING,
TOT_GROSS_MKT_AM TYPE STRING,
TOT_GROSS_RMB_AM TYPE STRING,
TOT_GROSS_TAX_AM TYPE STRING,
TOT_GROSS_TX_RMB TYPE STRING,
TOT_OWNER_MKT_AM TYPE STRING,
TOT_OWNER_RMB_AM TYPE STRING,
TOT_OWNER_TAX_AM TYPE STRING,
TOT_OWNER_TX_RMB TYPE STRING,
TOT_OTHER_DED_AM TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIUGR_ROYTXNA_NONKEY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-ALLOC_PERCENT sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-ENTITY_LINK_GUID sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-UNIT_VNAME sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-OPERATED_FL sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-LAND1 sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-REGIO sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-PRI_GEO_LOC sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-COUNC sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-SAKNR sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-ENTY_CD sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-PAY_CD sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-WAERS sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-VOL_UOM sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-ENERGY_UOM sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-HEAT_VAL_UOM sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-PRES_UOM sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-HEAT_VAL sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-PS_BASE_QY sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-GRAVITY sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-DISB_DECIMAL sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-NRI_DECIMAL sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-DOC_NO sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-DOC_YEAR sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-OPTION1 sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-OPTION2 sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-OPTION3 sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-INTERFACE_FL sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-OOS_FL sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-GROSS_VOL sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-GROSS_ENERGY sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-GROSS_PVR sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-GROSS_PTR sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-NET_VOL sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-OWNER_ENERGY sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-OWN_PVR sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-OWN_PTR sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-GROSS_VAL sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-NET_VAL sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-OWNER_GROSS_VAL sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-PROF_LINK_GUID sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-ADDRNUMBER sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-MASTER_LEVEL sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-MASTER_LINK_GUID sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-PRODUCT_CODE sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-REFERENCE_RUN_ID sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-TOT_GROSS_MKT_AM sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-TOT_GROSS_RMB_AM sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-TOT_GROSS_TAX_AM sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-TOT_GROSS_TX_RMB sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-TOT_OWNER_MKT_AM sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-TOT_OWNER_RMB_AM sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-TOT_OWNER_TAX_AM sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-TOT_OWNER_TX_RMB sy-vline
WA_ROIUGR_ROYTXNA_NONKEY_STR-TOT_OTHER_DED_AM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.