ABAP Select data from SAP table ROIJTSMAT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIJTSMAT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIJTSMAT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIJTSMAT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIJTSMAT TYPE STANDARD TABLE OF ROIJTSMAT,
      WA_ROIJTSMAT TYPE ROIJTSMAT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIJTSMAT> TYPE ROIJTSMAT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIJTSMAT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIJTSMAT
  INTO TABLE IT_ROIJTSMAT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIJTSMAT
*  INTO TABLE @DATA(IT_ROIJTSMAT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIJTSMAT INDEX 1 INTO DATA(WA_ROIJTSMAT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIJTSMAT ASSIGNING <ROIJTSMAT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIJTSMAT>-MANDT = 1.
<ROIJTSMAT>-TSYST = 1.
<ROIJTSMAT>-PMATNR = 1.
<ROIJTSMAT>-TSNAM = 1.
<ROIJTSMAT>-PMATNAME = 1.
ENDLOOP.

LOOP AT IT_ROIJTSMAT INTO WA_ROIJTSMAT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIJTSMAT-PWERK, sy-vline,
WA_ROIJTSMAT-RDUOM, sy-vline,
WA_ROIJTSMAT-RDCONV, sy-vline,
WA_ROIJTSMAT-PERIOD, sy-vline,
WA_ROIJTSMAT-PAST, sy-vline,
WA_ROIJTSMAT-TOLPCT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIJTSMAT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIJTSMAT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIJTSMAT INTO WA_ROIJTSMAT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field PMATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ROIJTSMAT-PMATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJTSMAT-PMATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RDUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIJTSMAT-RDUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJTSMAT-RDUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DATUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIJTSMAT-DATUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJTSMAT-DATUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PLUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIJTSMAT-PLUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJTSMAT-PLUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CYCUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIJTSMAT-CYCUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJTSMAT-CYCUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field INVUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIJTSMAT-INVUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJTSMAT-INVUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIJTSMAT-SPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJTSMAT-SPART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field OFFUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIJTSMAT-OFFUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJTSMAT-OFFUOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIJTSMAT_STR,
MANDT TYPE STRING,
TSYST TYPE STRING,
PMATNR TYPE STRING,
TSNAM TYPE STRING,
PMATNAME TYPE STRING,
PWERK TYPE STRING,
RDUOM TYPE STRING,
RDCONV TYPE STRING,
PERIOD TYPE STRING,
PAST TYPE STRING,
TOLPCT TYPE STRING,
TOLABS TYPE STRING,
PASTDATA TYPE STRING,
PHY_INV_FLG TYPE STRING,
PHY_INV TYPE STRING,
PHY_DATE TYPE STRING,
FCPAST TYPE STRING,
FCOFFSET TYPE STRING,
FCTYPE TYPE STRING,
PHYTMS TYPE STRING,
SRCTYPE TYPE STRING,
FCHORIZ TYPE STRING,
RVP TYPE STRING,
PLTYP TYPE STRING,
CALFLG TYPE STRING,
PLCAL TYPE STRING,
COVER TYPE STRING,
PLHOZ TYPE STRING,
DATUOM TYPE STRING,
PTSYST TYPE STRING,
PLUOM TYPE STRING,
CYCLE TYPE STRING,
CYCUOM TYPE STRING,
MAXLOT TYPE STRING,
MINLOT TYPE STRING,
INCLOT TYPE STRING,
INVUOM TYPE STRING,
MAXINV TYPE STRING,
TARGET TYPE STRING,
REORDER TYPE STRING,
SAFETY TYPE STRING,
UNPUMP TYPE STRING,
MININV TYPE STRING,
STSYST TYPE STRING,
SLOCID TYPE STRING,
SPART TYPE STRING,
SPOBJ TYPE STRING,
OFFPER TYPE STRING,
OFFUOM TYPE STRING,
RADIONOSRC TYPE STRING,
RADIOTSSRC TYPE STRING,
RADIOLOCSC TYPE STRING,
PLANAMPEL TYPE STRING,
PLANFLAG TYPE STRING,
SCFLAG TYPE STRING,
SERVICE TYPE STRING,
COVPROF TYPE STRING,
CALPROF TYPE STRING,
FACTORY TYPE STRING,
SFTTYPE TYPE STRING,
HISTHOZ TYPE STRING,
TSERVICE TYPE STRING,
TCOVPROF TYPE STRING,
TCALPROF TYPE STRING,
TFACTORY TYPE STRING,
TGTTYPE TYPE STRING,
THISTHOZ TYPE STRING,
FCCAL TYPE STRING,
FCPRF TYPE STRING,
TANKUPD TYPE STRING,
SFTLVL TYPE STRING,
HRLVL TYPE STRING,
SFTTDIND TYPE STRING,
TGTTDIND TYPE STRING,
PPTYP TYPE STRING,
BALANCE TYPE STRING,
ERDAT TYPE STRING,
ERZEIT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AEZEIT TYPE STRING,
AENAM TYPE STRING,
BLOIND TYPE STRING,
DELIND TYPE STRING,
TKTSELECT TYPE STRING,
AUTOCONFIRM TYPE STRING,
VRMOD TYPE STRING,
VINT1 TYPE STRING,
VINT2 TYPE STRING,
DEFSITYP TYPE STRING,
DEFDOCIND TYPE STRING,
SELECTFLAG TYPE STRING,
UPDATEFLAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIJTSMAT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIJTSMAT_STR-MANDT sy-vline
WA_ROIJTSMAT_STR-TSYST sy-vline
WA_ROIJTSMAT_STR-PMATNR sy-vline
WA_ROIJTSMAT_STR-TSNAM sy-vline
WA_ROIJTSMAT_STR-PMATNAME sy-vline
WA_ROIJTSMAT_STR-PWERK sy-vline
WA_ROIJTSMAT_STR-RDUOM sy-vline
WA_ROIJTSMAT_STR-RDCONV sy-vline
WA_ROIJTSMAT_STR-PERIOD sy-vline
WA_ROIJTSMAT_STR-PAST sy-vline
WA_ROIJTSMAT_STR-TOLPCT sy-vline
WA_ROIJTSMAT_STR-TOLABS sy-vline
WA_ROIJTSMAT_STR-PASTDATA sy-vline
WA_ROIJTSMAT_STR-PHY_INV_FLG sy-vline
WA_ROIJTSMAT_STR-PHY_INV sy-vline
WA_ROIJTSMAT_STR-PHY_DATE sy-vline
WA_ROIJTSMAT_STR-FCPAST sy-vline
WA_ROIJTSMAT_STR-FCOFFSET sy-vline
WA_ROIJTSMAT_STR-FCTYPE sy-vline
WA_ROIJTSMAT_STR-PHYTMS sy-vline
WA_ROIJTSMAT_STR-SRCTYPE sy-vline
WA_ROIJTSMAT_STR-FCHORIZ sy-vline
WA_ROIJTSMAT_STR-RVP sy-vline
WA_ROIJTSMAT_STR-PLTYP sy-vline
WA_ROIJTSMAT_STR-CALFLG sy-vline
WA_ROIJTSMAT_STR-PLCAL sy-vline
WA_ROIJTSMAT_STR-COVER sy-vline
WA_ROIJTSMAT_STR-PLHOZ sy-vline
WA_ROIJTSMAT_STR-DATUOM sy-vline
WA_ROIJTSMAT_STR-PTSYST sy-vline
WA_ROIJTSMAT_STR-PLUOM sy-vline
WA_ROIJTSMAT_STR-CYCLE sy-vline
WA_ROIJTSMAT_STR-CYCUOM sy-vline
WA_ROIJTSMAT_STR-MAXLOT sy-vline
WA_ROIJTSMAT_STR-MINLOT sy-vline
WA_ROIJTSMAT_STR-INCLOT sy-vline
WA_ROIJTSMAT_STR-INVUOM sy-vline
WA_ROIJTSMAT_STR-MAXINV sy-vline
WA_ROIJTSMAT_STR-TARGET sy-vline
WA_ROIJTSMAT_STR-REORDER sy-vline
WA_ROIJTSMAT_STR-SAFETY sy-vline
WA_ROIJTSMAT_STR-UNPUMP sy-vline
WA_ROIJTSMAT_STR-MININV sy-vline
WA_ROIJTSMAT_STR-STSYST sy-vline
WA_ROIJTSMAT_STR-SLOCID sy-vline
WA_ROIJTSMAT_STR-SPART sy-vline
WA_ROIJTSMAT_STR-SPOBJ sy-vline
WA_ROIJTSMAT_STR-OFFPER sy-vline
WA_ROIJTSMAT_STR-OFFUOM sy-vline
WA_ROIJTSMAT_STR-RADIONOSRC sy-vline
WA_ROIJTSMAT_STR-RADIOTSSRC sy-vline
WA_ROIJTSMAT_STR-RADIOLOCSC sy-vline
WA_ROIJTSMAT_STR-PLANAMPEL sy-vline
WA_ROIJTSMAT_STR-PLANFLAG sy-vline
WA_ROIJTSMAT_STR-SCFLAG sy-vline
WA_ROIJTSMAT_STR-SERVICE sy-vline
WA_ROIJTSMAT_STR-COVPROF sy-vline
WA_ROIJTSMAT_STR-CALPROF sy-vline
WA_ROIJTSMAT_STR-FACTORY sy-vline
WA_ROIJTSMAT_STR-SFTTYPE sy-vline
WA_ROIJTSMAT_STR-HISTHOZ sy-vline
WA_ROIJTSMAT_STR-TSERVICE sy-vline
WA_ROIJTSMAT_STR-TCOVPROF sy-vline
WA_ROIJTSMAT_STR-TCALPROF sy-vline
WA_ROIJTSMAT_STR-TFACTORY sy-vline
WA_ROIJTSMAT_STR-TGTTYPE sy-vline
WA_ROIJTSMAT_STR-THISTHOZ sy-vline
WA_ROIJTSMAT_STR-FCCAL sy-vline
WA_ROIJTSMAT_STR-FCPRF sy-vline
WA_ROIJTSMAT_STR-TANKUPD sy-vline
WA_ROIJTSMAT_STR-SFTLVL sy-vline
WA_ROIJTSMAT_STR-HRLVL sy-vline
WA_ROIJTSMAT_STR-SFTTDIND sy-vline
WA_ROIJTSMAT_STR-TGTTDIND sy-vline
WA_ROIJTSMAT_STR-PPTYP sy-vline
WA_ROIJTSMAT_STR-BALANCE sy-vline
WA_ROIJTSMAT_STR-ERDAT sy-vline
WA_ROIJTSMAT_STR-ERZEIT sy-vline
WA_ROIJTSMAT_STR-ERNAM sy-vline
WA_ROIJTSMAT_STR-AEDAT sy-vline
WA_ROIJTSMAT_STR-AEZEIT sy-vline
WA_ROIJTSMAT_STR-AENAM sy-vline
WA_ROIJTSMAT_STR-BLOIND sy-vline
WA_ROIJTSMAT_STR-DELIND sy-vline
WA_ROIJTSMAT_STR-TKTSELECT sy-vline
WA_ROIJTSMAT_STR-AUTOCONFIRM sy-vline
WA_ROIJTSMAT_STR-VRMOD sy-vline
WA_ROIJTSMAT_STR-VINT1 sy-vline
WA_ROIJTSMAT_STR-VINT2 sy-vline
WA_ROIJTSMAT_STR-DEFSITYP sy-vline
WA_ROIJTSMAT_STR-DEFDOCIND sy-vline
WA_ROIJTSMAT_STR-SELECTFLAG sy-vline
WA_ROIJTSMAT_STR-UPDATEFLAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.