ABAP Select data from SAP table ROIJNEIO_N into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIJNEIO_N table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIJNEIO_N. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIJNEIO_N table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIJNEIO_N TYPE STANDARD TABLE OF ROIJNEIO_N,
      WA_ROIJNEIO_N TYPE ROIJNEIO_N,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIJNEIO_N> TYPE ROIJNEIO_N.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIJNEIO_N.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIJNEIO_N
  INTO TABLE IT_ROIJNEIO_N.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIJNEIO_N
*  INTO TABLE @DATA(IT_ROIJNEIO_N2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIJNEIO_N INDEX 1 INTO DATA(WA_ROIJNEIO_N2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIJNEIO_N ASSIGNING <ROIJNEIO_N>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIJNEIO_N>-CLIENT = 1.
<ROIJNEIO_N>-NOMTK = 1.
<ROIJNEIO_N>-NOMIT = 1.
<ROIJNEIO_N>-EVENT_NR = 1.
<ROIJNEIO_N>-NOMNR = 1.
ENDLOOP.

LOOP AT IT_ROIJNEIO_N INTO WA_ROIJNEIO_N.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIJNEIO_N-TYPE, sy-vline,
WA_ROIJNEIO_N-DOC_TYPE, sy-vline,
WA_ROIJNEIO_N-UPDFLAG, sy-vline,
WA_ROIJNEIO_N-EV_SEQ, sy-vline,
WA_ROIJNEIO_N-DOC_NUMBER, sy-vline,
WA_ROIJNEIO_N-SHITEM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIJNEIO_N you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIJNEIO_N TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIJNEIO_N INTO WA_ROIJNEIO_N. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field NOMTK CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIJNEIO_N-NOMTK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJNEIO_N-NOMTK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EV_SEQ CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIJNEIO_N-EV_SEQ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJNEIO_N-EV_SEQ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOC_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIJNEIO_N-DOC_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJNEIO_N-DOC_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TICKET_KEY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIJNEIO_N-TICKET_KEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJNEIO_N-TICKET_KEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DRIVER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIJNEIO_N-DRIVER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJNEIO_N-DRIVER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CPARID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIJNEIO_N-CPARID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJNEIO_N-CPARID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN5, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN5_OUTPUT' EXPORTING input = WA_ROIJNEIO_N-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJNEIO_N-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BERID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIJNEIO_N-BERID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJNEIO_N-BERID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SI_DOC_NR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIJNEIO_N-SI_DOC_NR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJNEIO_N-SI_DOC_NR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VHLNMR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIJNEIO_N-VHLNMR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJNEIO_N-VHLNMR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR_LONG CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ROIJNEIO_N-MATNR_LONG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIJNEIO_N-MATNR_LONG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIJNEIO_N_STR,
CLIENT TYPE STRING,
NOMTK TYPE STRING,
NOMIT TYPE STRING,
EVENT_NR TYPE STRING,
NOMNR TYPE STRING,
TYPE TYPE STRING,
DOC_TYPE TYPE STRING,
UPDFLAG TYPE STRING,
EV_SEQ TYPE STRING,
DOC_NUMBER TYPE STRING,
SHITEM TYPE STRING,
STATUS TYPE STRING,
PSTDTF TYPE STRING,
PSTTMF TYPE STRING,
PSTDTT TYPE STRING,
PSTTMT TYPE STRING,
PEDDTF TYPE STRING,
PEDTMF TYPE STRING,
PEDDTT TYPE STRING,
PEDTMT TYPE STRING,
CRE_NAME TYPE STRING,
CRE_DATE TYPE STRING,
CRE_TIME TYPE STRING,
CHA_NAME TYPE STRING,
CHA_DATE TYPE STRING,
CHA_TIME TYPE STRING,
ASTDTF TYPE STRING,
ASTTMF TYPE STRING,
ASTDTT TYPE STRING,
ASTTMT TYPE STRING,
AEDDTF TYPE STRING,
AEDTMF TYPE STRING,
AEDDTT TYPE STRING,
AEDTMT TYPE STRING,
DEFAULTED TYPE STRING,
VEH_NR TYPE STRING,
TSRFO TYPE STRING,
TICKET_KEY TYPE STRING,
TICKET_ITEM TYPE STRING,
TICKET_EV_NR TYPE STRING,
TPNUM TYPE STRING,
DELIND TYPE STRING,
DRIVER TYPE STRING,
CPARID TYPE STRING,
ADD_QTY TYPE STRING,
ADQ_UOM TYPE STRING,
MATNR TYPE STRING,
LT_EVOPPOINT TYPE STRING,
BERNR TYPE STRING,
BERID TYPE STRING,
UPDKZ TYPE STRING,
SI_DOC_TYP TYPE STRING,
STATUSTEXT TYPE STRING,
LONGTEXT TYPE STRING,
SI_DOC_NR TYPE STRING,
TYPETEXT TYPE STRING,
EV_TEXT TYPE STRING,
DOC_ASGN TYPE STRING,
VEH_ASGN TYPE STRING,
VHLNMR TYPE STRING,
SI_ASGN TYPE STRING,
IC_DELIND TYPE STRING,
DEF TYPE STRING,
MATNR_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIJNEIO_N_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIJNEIO_N_STR-CLIENT sy-vline
WA_ROIJNEIO_N_STR-NOMTK sy-vline
WA_ROIJNEIO_N_STR-NOMIT sy-vline
WA_ROIJNEIO_N_STR-EVENT_NR sy-vline
WA_ROIJNEIO_N_STR-NOMNR sy-vline
WA_ROIJNEIO_N_STR-TYPE sy-vline
WA_ROIJNEIO_N_STR-DOC_TYPE sy-vline
WA_ROIJNEIO_N_STR-UPDFLAG sy-vline
WA_ROIJNEIO_N_STR-EV_SEQ sy-vline
WA_ROIJNEIO_N_STR-DOC_NUMBER sy-vline
WA_ROIJNEIO_N_STR-SHITEM sy-vline
WA_ROIJNEIO_N_STR-STATUS sy-vline
WA_ROIJNEIO_N_STR-PSTDTF sy-vline
WA_ROIJNEIO_N_STR-PSTTMF sy-vline
WA_ROIJNEIO_N_STR-PSTDTT sy-vline
WA_ROIJNEIO_N_STR-PSTTMT sy-vline
WA_ROIJNEIO_N_STR-PEDDTF sy-vline
WA_ROIJNEIO_N_STR-PEDTMF sy-vline
WA_ROIJNEIO_N_STR-PEDDTT sy-vline
WA_ROIJNEIO_N_STR-PEDTMT sy-vline
WA_ROIJNEIO_N_STR-CRE_NAME sy-vline
WA_ROIJNEIO_N_STR-CRE_DATE sy-vline
WA_ROIJNEIO_N_STR-CRE_TIME sy-vline
WA_ROIJNEIO_N_STR-CHA_NAME sy-vline
WA_ROIJNEIO_N_STR-CHA_DATE sy-vline
WA_ROIJNEIO_N_STR-CHA_TIME sy-vline
WA_ROIJNEIO_N_STR-ASTDTF sy-vline
WA_ROIJNEIO_N_STR-ASTTMF sy-vline
WA_ROIJNEIO_N_STR-ASTDTT sy-vline
WA_ROIJNEIO_N_STR-ASTTMT sy-vline
WA_ROIJNEIO_N_STR-AEDDTF sy-vline
WA_ROIJNEIO_N_STR-AEDTMF sy-vline
WA_ROIJNEIO_N_STR-AEDDTT sy-vline
WA_ROIJNEIO_N_STR-AEDTMT sy-vline
WA_ROIJNEIO_N_STR-DEFAULTED sy-vline
WA_ROIJNEIO_N_STR-VEH_NR sy-vline
WA_ROIJNEIO_N_STR-TSRFO sy-vline
WA_ROIJNEIO_N_STR-TICKET_KEY sy-vline
WA_ROIJNEIO_N_STR-TICKET_ITEM sy-vline
WA_ROIJNEIO_N_STR-TICKET_EV_NR sy-vline
WA_ROIJNEIO_N_STR-TPNUM sy-vline
WA_ROIJNEIO_N_STR-DELIND sy-vline
WA_ROIJNEIO_N_STR-DRIVER sy-vline
WA_ROIJNEIO_N_STR-CPARID sy-vline
WA_ROIJNEIO_N_STR-ADD_QTY sy-vline
WA_ROIJNEIO_N_STR-ADQ_UOM sy-vline
WA_ROIJNEIO_N_STR-MATNR sy-vline
WA_ROIJNEIO_N_STR-LT_EVOPPOINT sy-vline
WA_ROIJNEIO_N_STR-BERNR sy-vline
WA_ROIJNEIO_N_STR-BERID sy-vline
WA_ROIJNEIO_N_STR-UPDKZ sy-vline
WA_ROIJNEIO_N_STR-SI_DOC_TYP sy-vline
WA_ROIJNEIO_N_STR-STATUSTEXT sy-vline
WA_ROIJNEIO_N_STR-LONGTEXT sy-vline
WA_ROIJNEIO_N_STR-SI_DOC_NR sy-vline
WA_ROIJNEIO_N_STR-TYPETEXT sy-vline
WA_ROIJNEIO_N_STR-EV_TEXT sy-vline
WA_ROIJNEIO_N_STR-DOC_ASGN sy-vline
WA_ROIJNEIO_N_STR-VEH_ASGN sy-vline
WA_ROIJNEIO_N_STR-VHLNMR sy-vline
WA_ROIJNEIO_N_STR-SI_ASGN sy-vline
WA_ROIJNEIO_N_STR-IC_DELIND sy-vline
WA_ROIJNEIO_N_STR-DEF sy-vline
WA_ROIJNEIO_N_STR-MATNR_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.