ABAP Select data from SAP table ROIISOCB1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIISOCB1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIISOCB1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIISOCB1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIISOCB1 TYPE STANDARD TABLE OF ROIISOCB1,
      WA_ROIISOCB1 TYPE ROIISOCB1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIISOCB1> TYPE ROIISOCB1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIISOCB1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIISOCB1
  INTO TABLE IT_ROIISOCB1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIISOCB1
*  INTO TABLE @DATA(IT_ROIISOCB12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIISOCB1 INDEX 1 INTO DATA(WA_ROIISOCB12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIISOCB1 ASSIGNING <ROIISOCB1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIISOCB1>-MANDT = 1.
<ROIISOCB1>-SOCNR = 1.
<ROIISOCB1>-SLVNR = 1.
<ROIISOCB1>-MAXDP = 1.
<ROIISOCB1>-MINDP = 1.
ENDLOOP.

LOOP AT IT_ROIISOCB1 INTO WA_ROIISOCB1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIISOCB1-MAXIN, sy-vline,
WA_ROIISOCB1-MAXOUT, sy-vline,
WA_ROIISOCB1-UNPKZ, sy-vline,
WA_ROIISOCB1-UNPPC, sy-vline,
WA_ROIISOCB1-WASKZ, sy-vline,
WA_ROIISOCB1-WASPC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIISOCB1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIISOCB1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIISOCB1 INTO WA_ROIISOCB1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field VOLUN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIISOCB1-VOLUN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIISOCB1-VOLUN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LENUN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ROIISOCB1-LENUN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIISOCB1-LENUN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIISOCB1_STR,
MANDT TYPE STRING,
SOCNR TYPE STRING,
SLVNR TYPE STRING,
MAXDP TYPE STRING,
MINDP TYPE STRING,
MAXIN TYPE STRING,
MAXOUT TYPE STRING,
UNPKZ TYPE STRING,
UNPPC TYPE STRING,
WASKZ TYPE STRING,
WASPC TYPE STRING,
FLMAS TYPE STRING,
GFLAG TYPE STRING,
HFLAG TYPE STRING,
AZEIT TYPE STRING,
ERDAT TYPE STRING,
ERZEIT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AEZEIT TYPE STRING,
AENAM TYPE STRING,
BLOIND TYPE STRING,
DELIND TYPE STRING,
NRDEC TYPE STRING,
VOLUN TYPE STRING,
LENUN TYPE STRING,
UPD_FLAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIISOCB1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIISOCB1_STR-MANDT sy-vline
WA_ROIISOCB1_STR-SOCNR sy-vline
WA_ROIISOCB1_STR-SLVNR sy-vline
WA_ROIISOCB1_STR-MAXDP sy-vline
WA_ROIISOCB1_STR-MINDP sy-vline
WA_ROIISOCB1_STR-MAXIN sy-vline
WA_ROIISOCB1_STR-MAXOUT sy-vline
WA_ROIISOCB1_STR-UNPKZ sy-vline
WA_ROIISOCB1_STR-UNPPC sy-vline
WA_ROIISOCB1_STR-WASKZ sy-vline
WA_ROIISOCB1_STR-WASPC sy-vline
WA_ROIISOCB1_STR-FLMAS sy-vline
WA_ROIISOCB1_STR-GFLAG sy-vline
WA_ROIISOCB1_STR-HFLAG sy-vline
WA_ROIISOCB1_STR-AZEIT sy-vline
WA_ROIISOCB1_STR-ERDAT sy-vline
WA_ROIISOCB1_STR-ERZEIT sy-vline
WA_ROIISOCB1_STR-ERNAM sy-vline
WA_ROIISOCB1_STR-AEDAT sy-vline
WA_ROIISOCB1_STR-AEZEIT sy-vline
WA_ROIISOCB1_STR-AENAM sy-vline
WA_ROIISOCB1_STR-BLOIND sy-vline
WA_ROIISOCB1_STR-DELIND sy-vline
WA_ROIISOCB1_STR-NRDEC sy-vline
WA_ROIISOCB1_STR-VOLUN sy-vline
WA_ROIISOCB1_STR-LENUN sy-vline
WA_ROIISOCB1_STR-UPD_FLAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.