ABAP Select data from SAP table ROIISCPWK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIISCPWK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIISCPWK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIISCPWK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIISCPWK TYPE STANDARD TABLE OF ROIISCPWK,
      WA_ROIISCPWK TYPE ROIISCPWK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIISCPWK> TYPE ROIISCPWK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIISCPWK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIISCPWK
  INTO TABLE IT_ROIISCPWK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIISCPWK
*  INTO TABLE @DATA(IT_ROIISCPWK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIISCPWK INDEX 1 INTO DATA(WA_ROIISCPWK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIISCPWK ASSIGNING <ROIISCPWK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIISCPWK>-MANDT = 1.
<ROIISCPWK>-WERKS = 1.
<ROIISCPWK>-VKFCAL = 1.
<ROIISCPWK>-VKFSID = 1.
<ROIISCPWK>-W11BOS = 1.
ENDLOOP.

LOOP AT IT_ROIISCPWK INTO WA_ROIISCPWK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIISCPWK-W11EOS, sy-vline,
WA_ROIISCPWK-W12BOS, sy-vline,
WA_ROIISCPWK-W12EOS, sy-vline,
WA_ROIISCPWK-W21BOS, sy-vline,
WA_ROIISCPWK-W21EOS, sy-vline,
WA_ROIISCPWK-W22BOS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIISCPWK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIISCPWK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIISCPWK INTO WA_ROIISCPWK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIISCPWK_STR,
MANDT TYPE STRING,
WERKS TYPE STRING,
VKFCAL TYPE STRING,
VKFSID TYPE STRING,
W11BOS TYPE STRING,
W11EOS TYPE STRING,
W12BOS TYPE STRING,
W12EOS TYPE STRING,
W21BOS TYPE STRING,
W21EOS TYPE STRING,
W22BOS TYPE STRING,
W22EOS TYPE STRING,
W31BOS TYPE STRING,
W31EOS TYPE STRING,
W32BOS TYPE STRING,
W32EOS TYPE STRING,
W41BOS TYPE STRING,
W41EOS TYPE STRING,
W42BOS TYPE STRING,
W42EOS TYPE STRING,
W51BOS TYPE STRING,
W51EOS TYPE STRING,
W52BOS TYPE STRING,
W52EOS TYPE STRING,
W61BOS TYPE STRING,
W61EOS TYPE STRING,
W62BOS TYPE STRING,
W62EOS TYPE STRING,
W71BOS TYPE STRING,
W71EOS TYPE STRING,
W72BOS TYPE STRING,
W72EOS TYPE STRING,
W81BOS TYPE STRING,
W81EOS TYPE STRING,
W82BOS TYPE STRING,
W82EOS TYPE STRING,
ERDAT TYPE STRING,
ERZEIT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AEZEIT TYPE STRING,
AENAM TYPE STRING,
BLOIND TYPE STRING,
DELIND TYPE STRING,
BLOSH TYPE STRING,
BLOLT TYPE STRING,
SOEGRP TYPE STRING,
TPIPRD TYPE STRING,
CONWK TYPE STRING,
CONLG TYPE STRING,
RCBLK TYPE STRING,
DOBLK TYPE STRING,
UPD_FLAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIISCPWK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIISCPWK_STR-MANDT sy-vline
WA_ROIISCPWK_STR-WERKS sy-vline
WA_ROIISCPWK_STR-VKFCAL sy-vline
WA_ROIISCPWK_STR-VKFSID sy-vline
WA_ROIISCPWK_STR-W11BOS sy-vline
WA_ROIISCPWK_STR-W11EOS sy-vline
WA_ROIISCPWK_STR-W12BOS sy-vline
WA_ROIISCPWK_STR-W12EOS sy-vline
WA_ROIISCPWK_STR-W21BOS sy-vline
WA_ROIISCPWK_STR-W21EOS sy-vline
WA_ROIISCPWK_STR-W22BOS sy-vline
WA_ROIISCPWK_STR-W22EOS sy-vline
WA_ROIISCPWK_STR-W31BOS sy-vline
WA_ROIISCPWK_STR-W31EOS sy-vline
WA_ROIISCPWK_STR-W32BOS sy-vline
WA_ROIISCPWK_STR-W32EOS sy-vline
WA_ROIISCPWK_STR-W41BOS sy-vline
WA_ROIISCPWK_STR-W41EOS sy-vline
WA_ROIISCPWK_STR-W42BOS sy-vline
WA_ROIISCPWK_STR-W42EOS sy-vline
WA_ROIISCPWK_STR-W51BOS sy-vline
WA_ROIISCPWK_STR-W51EOS sy-vline
WA_ROIISCPWK_STR-W52BOS sy-vline
WA_ROIISCPWK_STR-W52EOS sy-vline
WA_ROIISCPWK_STR-W61BOS sy-vline
WA_ROIISCPWK_STR-W61EOS sy-vline
WA_ROIISCPWK_STR-W62BOS sy-vline
WA_ROIISCPWK_STR-W62EOS sy-vline
WA_ROIISCPWK_STR-W71BOS sy-vline
WA_ROIISCPWK_STR-W71EOS sy-vline
WA_ROIISCPWK_STR-W72BOS sy-vline
WA_ROIISCPWK_STR-W72EOS sy-vline
WA_ROIISCPWK_STR-W81BOS sy-vline
WA_ROIISCPWK_STR-W81EOS sy-vline
WA_ROIISCPWK_STR-W82BOS sy-vline
WA_ROIISCPWK_STR-W82EOS sy-vline
WA_ROIISCPWK_STR-ERDAT sy-vline
WA_ROIISCPWK_STR-ERZEIT sy-vline
WA_ROIISCPWK_STR-ERNAM sy-vline
WA_ROIISCPWK_STR-AEDAT sy-vline
WA_ROIISCPWK_STR-AEZEIT sy-vline
WA_ROIISCPWK_STR-AENAM sy-vline
WA_ROIISCPWK_STR-BLOIND sy-vline
WA_ROIISCPWK_STR-DELIND sy-vline
WA_ROIISCPWK_STR-BLOSH sy-vline
WA_ROIISCPWK_STR-BLOLT sy-vline
WA_ROIISCPWK_STR-SOEGRP sy-vline
WA_ROIISCPWK_STR-TPIPRD sy-vline
WA_ROIISCPWK_STR-CONWK sy-vline
WA_ROIISCPWK_STR-CONLG sy-vline
WA_ROIISCPWK_STR-RCBLK sy-vline
WA_ROIISCPWK_STR-DOBLK sy-vline
WA_ROIISCPWK_STR-UPD_FLAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.