ABAP Select data from SAP table ROIHLO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ROIHLO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ROIHLO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ROIHLO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ROIHLO TYPE STANDARD TABLE OF ROIHLO,
      WA_ROIHLO TYPE ROIHLO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ROIHLO> TYPE ROIHLO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ROIHLO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ROIHLO
  INTO TABLE IT_ROIHLO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ROIHLO
*  INTO TABLE @DATA(IT_ROIHLO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ROIHLO INDEX 1 INTO DATA(WA_ROIHLO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ROIHLO ASSIGNING <ROIHLO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ROIHLO>-MANDT = 1.
<ROIHLO>-VBELN = 1.
<ROIHLO>-POSNR = 1.
<ROIHLO>-KSCHL = 1.
<ROIHLO>-ZAEHK = 1.
ENDLOOP.

LOOP AT IT_ROIHLO INTO WA_ROIHLO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ROIHLO-LICTP, sy-vline,
WA_ROIHLO-LICIN, sy-vline,
WA_ROIHLO-SELKZ, sy-vline,
WA_ROIHLO-LICTT, sy-vline,
WA_ROIHLO-CERTF1, sy-vline,
WA_ROIHLO-KUNNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ROIHLO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ROIHLO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ROIHLO INTO WA_ROIHLO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIHLO-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIHLO-VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LICIN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIHLO-LICIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIHLO-LICIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ROIHLO-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIHLO-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ROIHLO-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ROIHLO-MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ROIHLO_STR,
MANDT TYPE STRING,
VBELN TYPE STRING,
POSNR TYPE STRING,
KSCHL TYPE STRING,
ZAEHK TYPE STRING,
LICTP TYPE STRING,
LICIN TYPE STRING,
SELKZ TYPE STRING,
LICTT TYPE STRING,
CERTF1 TYPE STRING,
KUNNR TYPE STRING,
KVGR1 TYPE STRING,
MVGR2 TYPE STRING,
MATNR TYPE STRING,
LCOMP TYPE STRING,
LCUST TYPE STRING,
DATAB TYPE STRING,
DATBI TYPE STRING,
LAND1 TYPE STRING,
REGIO TYPE STRING,
COUNC TYPE STRING,
CITYC TYPE STRING,
ALTLC TYPE STRING,END OF T_EKKO_STR. DATA: WA_ROIHLO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ROIHLO_STR-MANDT sy-vline
WA_ROIHLO_STR-VBELN sy-vline
WA_ROIHLO_STR-POSNR sy-vline
WA_ROIHLO_STR-KSCHL sy-vline
WA_ROIHLO_STR-ZAEHK sy-vline
WA_ROIHLO_STR-LICTP sy-vline
WA_ROIHLO_STR-LICIN sy-vline
WA_ROIHLO_STR-SELKZ sy-vline
WA_ROIHLO_STR-LICTT sy-vline
WA_ROIHLO_STR-CERTF1 sy-vline
WA_ROIHLO_STR-KUNNR sy-vline
WA_ROIHLO_STR-KVGR1 sy-vline
WA_ROIHLO_STR-MVGR2 sy-vline
WA_ROIHLO_STR-MATNR sy-vline
WA_ROIHLO_STR-LCOMP sy-vline
WA_ROIHLO_STR-LCUST sy-vline
WA_ROIHLO_STR-DATAB sy-vline
WA_ROIHLO_STR-DATBI sy-vline
WA_ROIHLO_STR-LAND1 sy-vline
WA_ROIHLO_STR-REGIO sy-vline
WA_ROIHLO_STR-COUNC sy-vline
WA_ROIHLO_STR-CITYC sy-vline
WA_ROIHLO_STR-ALTLC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.