ABAP Select data from SAP table RNV2000_PAT_ADDRESS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RNV2000_PAT_ADDRESS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RNV2000_PAT_ADDRESS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RNV2000_PAT_ADDRESS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RNV2000_PAT_ADDRESS TYPE STANDARD TABLE OF RNV2000_PAT_ADDRESS,
      WA_RNV2000_PAT_ADDRESS TYPE RNV2000_PAT_ADDRESS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RNV2000_PAT_ADDRESS> TYPE RNV2000_PAT_ADDRESS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RNV2000_PAT_ADDRESS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RNV2000_PAT_ADDRESS
  INTO TABLE IT_RNV2000_PAT_ADDRESS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RNV2000_PAT_ADDRESS
*  INTO TABLE @DATA(IT_RNV2000_PAT_ADDRESS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RNV2000_PAT_ADDRESS INDEX 1 INTO DATA(WA_RNV2000_PAT_ADDRESS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RNV2000_PAT_ADDRESS ASSIGNING <RNV2000_PAT_ADDRESS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RNV2000_PAT_ADDRESS>-PSTLZ = 1.
<RNV2000_PAT_ADDRESS>-LAND = 1.
<RNV2000_PAT_ADDRESS>-REGIO = 1.
<RNV2000_PAT_ADDRESS>-ORT = 1.
<RNV2000_PAT_ADDRESS>-ORT2 = 1.
ENDLOOP.

LOOP AT IT_RNV2000_PAT_ADDRESS INTO WA_RNV2000_PAT_ADDRESS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RNV2000_PAT_ADDRESS-STRAS, sy-vline,
WA_RNV2000_PAT_ADDRESS-STRAZ, sy-vline,
WA_RNV2000_PAT_ADDRESS-EINZG, sy-vline,
WA_RNV2000_PAT_ADDRESS-PSTLP, sy-vline,
WA_RNV2000_PAT_ADDRESS-PFACH, sy-vline,
WA_RNV2000_PAT_ADDRESS-LANPF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RNV2000_PAT_ADDRESS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RNV2000_PAT_ADDRESS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RNV2000_PAT_ADDRESS INTO WA_RNV2000_PAT_ADDRESS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit SXIDN, internal->external for field EMAIL CALL FUNCTION 'CONVERSION_EXIT_SXIDN_OUTPUT' EXPORTING input = WA_RNV2000_PAT_ADDRESS-EMAIL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RNV2000_PAT_ADDRESS-EMAIL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RNV2000_PAT_ADDRESS_STR,
PSTLZ TYPE STRING,
LAND TYPE STRING,
REGIO TYPE STRING,
ORT TYPE STRING,
ORT2 TYPE STRING,
STRAS TYPE STRING,
STRAZ TYPE STRING,
EINZG TYPE STRING,
PSTLP TYPE STRING,
PFACH TYPE STRING,
LANPF TYPE STRING,
ORTPF TYPE STRING,
PSTLF TYPE STRING,
TELNO TYPE STRING,
FAXNR TYPE STRING,
FAXXT TYPE STRING,
TEXNR TYPE STRING,
BUILD TYPE STRING,
FLOOR TYPE STRING,
ROOM TYPE STRING,
EMAIL TYPE STRING,
HSNM1 TYPE STRING,
PSTLZX TYPE STRING,
LANDX TYPE STRING,
REGIOX TYPE STRING,
ORTX TYPE STRING,
ORT2X TYPE STRING,
STRASX TYPE STRING,
STRAZX TYPE STRING,
EINZGX TYPE STRING,
PSTLPX TYPE STRING,
PFACHX TYPE STRING,
LANPFX TYPE STRING,
ORTPFX TYPE STRING,
PSTLFX TYPE STRING,
TELNOX TYPE STRING,
FAXNRX TYPE STRING,
FAXXTX TYPE STRING,
TEXNRX TYPE STRING,
BUILDX TYPE STRING,
FLOORX TYPE STRING,
ROOMX TYPE STRING,
EMAILX TYPE STRING,
HSNM1X TYPE STRING,END OF T_EKKO_STR. DATA: WA_RNV2000_PAT_ADDRESS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RNV2000_PAT_ADDRESS_STR-PSTLZ sy-vline
WA_RNV2000_PAT_ADDRESS_STR-LAND sy-vline
WA_RNV2000_PAT_ADDRESS_STR-REGIO sy-vline
WA_RNV2000_PAT_ADDRESS_STR-ORT sy-vline
WA_RNV2000_PAT_ADDRESS_STR-ORT2 sy-vline
WA_RNV2000_PAT_ADDRESS_STR-STRAS sy-vline
WA_RNV2000_PAT_ADDRESS_STR-STRAZ sy-vline
WA_RNV2000_PAT_ADDRESS_STR-EINZG sy-vline
WA_RNV2000_PAT_ADDRESS_STR-PSTLP sy-vline
WA_RNV2000_PAT_ADDRESS_STR-PFACH sy-vline
WA_RNV2000_PAT_ADDRESS_STR-LANPF sy-vline
WA_RNV2000_PAT_ADDRESS_STR-ORTPF sy-vline
WA_RNV2000_PAT_ADDRESS_STR-PSTLF sy-vline
WA_RNV2000_PAT_ADDRESS_STR-TELNO sy-vline
WA_RNV2000_PAT_ADDRESS_STR-FAXNR sy-vline
WA_RNV2000_PAT_ADDRESS_STR-FAXXT sy-vline
WA_RNV2000_PAT_ADDRESS_STR-TEXNR sy-vline
WA_RNV2000_PAT_ADDRESS_STR-BUILD sy-vline
WA_RNV2000_PAT_ADDRESS_STR-FLOOR sy-vline
WA_RNV2000_PAT_ADDRESS_STR-ROOM sy-vline
WA_RNV2000_PAT_ADDRESS_STR-EMAIL sy-vline
WA_RNV2000_PAT_ADDRESS_STR-HSNM1 sy-vline
WA_RNV2000_PAT_ADDRESS_STR-PSTLZX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-LANDX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-REGIOX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-ORTX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-ORT2X sy-vline
WA_RNV2000_PAT_ADDRESS_STR-STRASX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-STRAZX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-EINZGX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-PSTLPX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-PFACHX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-LANPFX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-ORTPFX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-PSTLFX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-TELNOX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-FAXNRX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-FAXXTX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-TEXNRX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-BUILDX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-FLOORX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-ROOMX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-EMAILX sy-vline
WA_RNV2000_PAT_ADDRESS_STR-HSNM1X sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.