ABAP Select data from SAP table RNPATFIND_OUT_FW into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RNPATFIND_OUT_FW table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RNPATFIND_OUT_FW. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RNPATFIND_OUT_FW table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RNPATFIND_OUT_FW TYPE STANDARD TABLE OF RNPATFIND_OUT_FW,
      WA_RNPATFIND_OUT_FW TYPE RNPATFIND_OUT_FW,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RNPATFIND_OUT_FW> TYPE RNPATFIND_OUT_FW.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RNPATFIND_OUT_FW.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RNPATFIND_OUT_FW
  INTO TABLE IT_RNPATFIND_OUT_FW.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RNPATFIND_OUT_FW
*  INTO TABLE @DATA(IT_RNPATFIND_OUT_FW2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RNPATFIND_OUT_FW INDEX 1 INTO DATA(WA_RNPATFIND_OUT_FW2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RNPATFIND_OUT_FW ASSIGNING <RNPATFIND_OUT_FW>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RNPATFIND_OUT_FW>-KEY_DATA = 1.
<RNPATFIND_OUT_FW>-MANDT = 1.
<RNPATFIND_OUT_FW>-GUID = 1.
<RNPATFIND_OUT_FW>-EVENT = 1.
<RNPATFIND_OUT_FW>-APPLK = 1.
ENDLOOP.

LOOP AT IT_RNPATFIND_OUT_FW INTO WA_RNPATFIND_OUT_FW.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RNPATFIND_OUT_FW-EINRI, sy-vline,
WA_RNPATFIND_OUT_FW-FALNR, sy-vline,
WA_RNPATFIND_OUT_FW-LFDNR, sy-vline,
WA_RNPATFIND_OUT_FW-PATNR, sy-vline,
WA_RNPATFIND_OUT_FW-EXTNR, sy-vline,
WA_RNPATFIND_OUT_FW-KOSTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RNPATFIND_OUT_FW you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RNPATFIND_OUT_FW TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RNPATFIND_OUT_FW INTO WA_RNPATFIND_OUT_FW. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EINRI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RNPATFIND_OUT_FW-EINRI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RNPATFIND_OUT_FW-EINRI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FALNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RNPATFIND_OUT_FW-FALNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RNPATFIND_OUT_FW-FALNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PATNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RNPATFIND_OUT_FW-PATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RNPATFIND_OUT_FW-PATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RNPATFIND_OUT_FW-KOSTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RNPATFIND_OUT_FW-KOSTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LASTPATNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RNPATFIND_OUT_FW-LASTPATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RNPATFIND_OUT_FW-LASTPATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RNPATFIND_OUT_FW_STR,
KEY_DATA TYPE STRING,
MANDT TYPE STRING,
GUID TYPE STRING,
EVENT TYPE STRING,
APPLK TYPE STRING,
EINRI TYPE STRING,
FALNR TYPE STRING,
LFDNR TYPE STRING,
PATNR TYPE STRING,
EXTNR TYPE STRING,
KOSTR TYPE STRING,
COMNUM TYPE STRING,
KEY1 TYPE STRING,
KEY2 TYPE STRING,
KEY3 TYPE STRING,
KEY4 TYPE STRING,
KEY5 TYPE STRING,
KEY6 TYPE STRING,
ERDAT TYPE STRING,
ERTIM TYPE STRING,
ERUSR TYPE STRING,
TA TYPE STRING,
DATA_TYPE TYPE STRING,
REF_GUID TYPE STRING,
SEARCH_DATA TYPE STRING,
PATLIST_T TYPE STRING,
RETCNT TYPE STRING,
MOREAVAIL TYPE STRING,
RETMAXTYPE TYPE STRING,
RETURN_T TYPE STRING,
LASTPATNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_RNPATFIND_OUT_FW_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RNPATFIND_OUT_FW_STR-KEY_DATA sy-vline
WA_RNPATFIND_OUT_FW_STR-MANDT sy-vline
WA_RNPATFIND_OUT_FW_STR-GUID sy-vline
WA_RNPATFIND_OUT_FW_STR-EVENT sy-vline
WA_RNPATFIND_OUT_FW_STR-APPLK sy-vline
WA_RNPATFIND_OUT_FW_STR-EINRI sy-vline
WA_RNPATFIND_OUT_FW_STR-FALNR sy-vline
WA_RNPATFIND_OUT_FW_STR-LFDNR sy-vline
WA_RNPATFIND_OUT_FW_STR-PATNR sy-vline
WA_RNPATFIND_OUT_FW_STR-EXTNR sy-vline
WA_RNPATFIND_OUT_FW_STR-KOSTR sy-vline
WA_RNPATFIND_OUT_FW_STR-COMNUM sy-vline
WA_RNPATFIND_OUT_FW_STR-KEY1 sy-vline
WA_RNPATFIND_OUT_FW_STR-KEY2 sy-vline
WA_RNPATFIND_OUT_FW_STR-KEY3 sy-vline
WA_RNPATFIND_OUT_FW_STR-KEY4 sy-vline
WA_RNPATFIND_OUT_FW_STR-KEY5 sy-vline
WA_RNPATFIND_OUT_FW_STR-KEY6 sy-vline
WA_RNPATFIND_OUT_FW_STR-ERDAT sy-vline
WA_RNPATFIND_OUT_FW_STR-ERTIM sy-vline
WA_RNPATFIND_OUT_FW_STR-ERUSR sy-vline
WA_RNPATFIND_OUT_FW_STR-TA sy-vline
WA_RNPATFIND_OUT_FW_STR-DATA_TYPE sy-vline
WA_RNPATFIND_OUT_FW_STR-REF_GUID sy-vline
WA_RNPATFIND_OUT_FW_STR-SEARCH_DATA sy-vline
WA_RNPATFIND_OUT_FW_STR-PATLIST_T sy-vline
WA_RNPATFIND_OUT_FW_STR-RETCNT sy-vline
WA_RNPATFIND_OUT_FW_STR-MOREAVAIL sy-vline
WA_RNPATFIND_OUT_FW_STR-RETMAXTYPE sy-vline
WA_RNPATFIND_OUT_FW_STR-RETURN_T sy-vline
WA_RNPATFIND_OUT_FW_STR-LASTPATNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.