ABAP Select data from SAP table RN2BCPCLIR_DATA_COMPLETE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RN2BCPCLIR_DATA_COMPLETE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RN2BCPCLIR_DATA_COMPLETE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RN2BCPCLIR_DATA_COMPLETE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RN2BCPCLIR_DATA_COMPLETE TYPE STANDARD TABLE OF RN2BCPCLIR_DATA_COMPLETE,
      WA_RN2BCPCLIR_DATA_COMPLETE TYPE RN2BCPCLIR_DATA_COMPLETE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RN2BCPCLIR_DATA_COMPLETE> TYPE RN2BCPCLIR_DATA_COMPLETE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RN2BCPCLIR_DATA_COMPLETE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RN2BCPCLIR_DATA_COMPLETE
  INTO TABLE IT_RN2BCPCLIR_DATA_COMPLETE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RN2BCPCLIR_DATA_COMPLETE
*  INTO TABLE @DATA(IT_RN2BCPCLIR_DATA_COMPLETE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RN2BCPCLIR_DATA_COMPLETE INDEX 1 INTO DATA(WA_RN2BCPCLIR_DATA_COMPLETE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RN2BCPCLIR_DATA_COMPLETE ASSIGNING <RN2BCPCLIR_DATA_COMPLETE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RN2BCPCLIR_DATA_COMPLETE>-MANDT = 1.
<RN2BCPCLIR_DATA_COMPLETE>-BCHID = 1.
<RN2BCPCLIR_DATA_COMPLETE>-BCPID = 1.
<RN2BCPCLIR_DATA_COMPLETE>-EXTID = 1.
<RN2BCPCLIR_DATA_COMPLETE>-IS_GROUP = 1.
ENDLOOP.

LOOP AT IT_RN2BCPCLIR_DATA_COMPLETE INTO WA_RN2BCPCLIR_DATA_COMPLETE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RN2BCPCLIR_DATA_COMPLETE-IS_SELECTABLE, sy-vline,
WA_RN2BCPCLIR_DATA_COMPLETE-IS_DELIMITED, sy-vline,
WA_RN2BCPCLIR_DATA_COMPLETE-DELIMIT_BCPID, sy-vline,
WA_RN2BCPCLIR_DATA_COMPLETE-VFDAT, sy-vline,
WA_RN2BCPCLIR_DATA_COMPLETE-VFTIM, sy-vline,
WA_RN2BCPCLIR_DATA_COMPLETE-VTDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RN2BCPCLIR_DATA_COMPLETE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RN2BCPCLIR_DATA_COMPLETE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RN2BCPCLIR_DATA_COMPLETE INTO WA_RN2BCPCLIR_DATA_COMPLETE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field RANGE_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RN2BCPCLIR_DATA_COMPLETE-RANGE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN2BCPCLIR_DATA_COMPLETE-RANGE_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RN2BCPCLIR_DATA_COMPLETE_STR,
MANDT TYPE STRING,
BCHID TYPE STRING,
BCPID TYPE STRING,
EXTID TYPE STRING,
IS_GROUP TYPE STRING,
IS_SELECTABLE TYPE STRING,
IS_DELIMITED TYPE STRING,
DELIMIT_BCPID TYPE STRING,
VFDAT TYPE STRING,
VFTIM TYPE STRING,
VTDAT TYPE STRING,
VTTIM TYPE STRING,
ERDAT TYPE STRING,
ERTIM TYPE STRING,
ERUSR TYPE STRING,
UPDAT TYPE STRING,
UPTIM TYPE STRING,
UPUSR TYPE STRING,
LOEKZ TYPE STRING,
LODAT TYPE STRING,
LOTIM TYPE STRING,
LOUSR TYPE STRING,
TIMESTAMP TYPE STRING,
EXTID_N TYPE STRING,
RANGE_TYPE TYPE STRING,
PERCENTAGE_VAL TYPE STRING,
SEX TYPE STRING,
AGE_LOW TYPE STRING,
AGE_HIGH TYPE STRING,
AGE_UNIT TYPE STRING,
PREGNANT TYPE STRING,
FASTING TYPE STRING,
WSTATE TYPE STRING,
RANGE_LOW TYPE STRING,
RANGE_HIGH TYPE STRING,
RANGE_UNIT TYPE STRING,END OF T_EKKO_STR. DATA: WA_RN2BCPCLIR_DATA_COMPLETE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-MANDT sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-BCHID sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-BCPID sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-EXTID sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-IS_GROUP sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-IS_SELECTABLE sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-IS_DELIMITED sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-DELIMIT_BCPID sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-VFDAT sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-VFTIM sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-VTDAT sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-VTTIM sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-ERDAT sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-ERTIM sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-ERUSR sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-UPDAT sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-UPTIM sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-UPUSR sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-LOEKZ sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-LODAT sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-LOTIM sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-LOUSR sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-TIMESTAMP sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-EXTID_N sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-RANGE_TYPE sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-PERCENTAGE_VAL sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-SEX sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-AGE_LOW sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-AGE_HIGH sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-AGE_UNIT sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-PREGNANT sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-FASTING sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-WSTATE sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-RANGE_LOW sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-RANGE_HIGH sy-vline
WA_RN2BCPCLIR_DATA_COMPLETE_STR-RANGE_UNIT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.