ABAP Select data from SAP table RN2_BASEITEM_REQUEST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RN2_BASEITEM_REQUEST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RN2_BASEITEM_REQUEST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RN2_BASEITEM_REQUEST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RN2_BASEITEM_REQUEST TYPE STANDARD TABLE OF RN2_BASEITEM_REQUEST,
      WA_RN2_BASEITEM_REQUEST TYPE RN2_BASEITEM_REQUEST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RN2_BASEITEM_REQUEST> TYPE RN2_BASEITEM_REQUEST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RN2_BASEITEM_REQUEST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RN2_BASEITEM_REQUEST
  INTO TABLE IT_RN2_BASEITEM_REQUEST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RN2_BASEITEM_REQUEST
*  INTO TABLE @DATA(IT_RN2_BASEITEM_REQUEST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RN2_BASEITEM_REQUEST INDEX 1 INTO DATA(WA_RN2_BASEITEM_REQUEST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RN2_BASEITEM_REQUEST ASSIGNING <RN2_BASEITEM_REQUEST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RN2_BASEITEM_REQUEST>-MANDT = 1.
<RN2_BASEITEM_REQUEST>-BASEITEMID = 1.
<RN2_BASEITEM_REQUEST>-EINRI = 1.
<RN2_BASEITEM_REQUEST>-NAME = 1.
<RN2_BASEITEM_REQUEST>-STATUS = 1.
ENDLOOP.

LOOP AT IT_RN2_BASEITEM_REQUEST INTO WA_RN2_BASEITEM_REQUEST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RN2_BASEITEM_REQUEST-ITEMTYPE, sy-vline,
WA_RN2_BASEITEM_REQUEST-ACTION_ID_FIRST, sy-vline,
WA_RN2_BASEITEM_REQUEST-ACTION_ID_AGAIN, sy-vline,
WA_RN2_BASEITEM_REQUEST-EXIT_BEFORE_FLT, sy-vline,
WA_RN2_BASEITEM_REQUEST-EXIT_EXEC_FLT, sy-vline,
WA_RN2_BASEITEM_REQUEST-EXIT_AFTER_FLT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RN2_BASEITEM_REQUEST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RN2_BASEITEM_REQUEST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RN2_BASEITEM_REQUEST INTO WA_RN2_BASEITEM_REQUEST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EINRI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RN2_BASEITEM_REQUEST-EINRI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN2_BASEITEM_REQUEST-EINRI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ORGID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RN2_BASEITEM_REQUEST-ORGID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN2_BASEITEM_REQUEST-ORGID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANFOE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RN2_BASEITEM_REQUEST-ANFOE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN2_BASEITEM_REQUEST-ANFOE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANPOE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RN2_BASEITEM_REQUEST-ANPOE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN2_BASEITEM_REQUEST-ANPOE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RN2_BASEITEM_REQUEST-GPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN2_BASEITEM_REQUEST-GPART.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RN2_BASEITEM_REQUEST_STR,
MANDT TYPE STRING,
BASEITEMID TYPE STRING,
EINRI TYPE STRING,
NAME TYPE STRING,
STATUS TYPE STRING,
ITEMTYPE TYPE STRING,
ACTION_ID_FIRST TYPE STRING,
ACTION_ID_AGAIN TYPE STRING,
EXIT_BEFORE_FLT TYPE STRING,
EXIT_EXEC_FLT TYPE STRING,
EXIT_AFTER_FLT TYPE STRING,
SERIALIZED TYPE STRING,
ERDAT TYPE STRING,
ERTIM TYPE STRING,
ERUSR TYPE STRING,
UPDAT TYPE STRING,
UPTIM TYPE STRING,
UPUSR TYPE STRING,
LOEKZ TYPE STRING,
LOUSR TYPE STRING,
LODAT TYPE STRING,
LOTIM TYPE STRING,
TIMESTAMP TYPE STRING,
ICON TYPE STRING,
DESCR TYPE STRING,
QUICKINFO TYPE STRING,
ORGID TYPE STRING,
ANFOE TYPE STRING,
ANPOE TYPE STRING,
ANFTY TYPE STRING,
GPART TYPE STRING,
KANAM TYPE STRING,
FRAGE TYPE STRING,
APRIE TYPE STRING,
ZWBGDT_OFF TYPE STRING,
WBGZT TYPE STRING,
SEL_SCREEN TYPE STRING,
SERVICE TYPE STRING,
NOCASE TYPE STRING,
USE_PROFILE TYPE STRING,
KANAM_LT TYPE STRING,END OF T_EKKO_STR. DATA: WA_RN2_BASEITEM_REQUEST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RN2_BASEITEM_REQUEST_STR-MANDT sy-vline
WA_RN2_BASEITEM_REQUEST_STR-BASEITEMID sy-vline
WA_RN2_BASEITEM_REQUEST_STR-EINRI sy-vline
WA_RN2_BASEITEM_REQUEST_STR-NAME sy-vline
WA_RN2_BASEITEM_REQUEST_STR-STATUS sy-vline
WA_RN2_BASEITEM_REQUEST_STR-ITEMTYPE sy-vline
WA_RN2_BASEITEM_REQUEST_STR-ACTION_ID_FIRST sy-vline
WA_RN2_BASEITEM_REQUEST_STR-ACTION_ID_AGAIN sy-vline
WA_RN2_BASEITEM_REQUEST_STR-EXIT_BEFORE_FLT sy-vline
WA_RN2_BASEITEM_REQUEST_STR-EXIT_EXEC_FLT sy-vline
WA_RN2_BASEITEM_REQUEST_STR-EXIT_AFTER_FLT sy-vline
WA_RN2_BASEITEM_REQUEST_STR-SERIALIZED sy-vline
WA_RN2_BASEITEM_REQUEST_STR-ERDAT sy-vline
WA_RN2_BASEITEM_REQUEST_STR-ERTIM sy-vline
WA_RN2_BASEITEM_REQUEST_STR-ERUSR sy-vline
WA_RN2_BASEITEM_REQUEST_STR-UPDAT sy-vline
WA_RN2_BASEITEM_REQUEST_STR-UPTIM sy-vline
WA_RN2_BASEITEM_REQUEST_STR-UPUSR sy-vline
WA_RN2_BASEITEM_REQUEST_STR-LOEKZ sy-vline
WA_RN2_BASEITEM_REQUEST_STR-LOUSR sy-vline
WA_RN2_BASEITEM_REQUEST_STR-LODAT sy-vline
WA_RN2_BASEITEM_REQUEST_STR-LOTIM sy-vline
WA_RN2_BASEITEM_REQUEST_STR-TIMESTAMP sy-vline
WA_RN2_BASEITEM_REQUEST_STR-ICON sy-vline
WA_RN2_BASEITEM_REQUEST_STR-DESCR sy-vline
WA_RN2_BASEITEM_REQUEST_STR-QUICKINFO sy-vline
WA_RN2_BASEITEM_REQUEST_STR-ORGID sy-vline
WA_RN2_BASEITEM_REQUEST_STR-ANFOE sy-vline
WA_RN2_BASEITEM_REQUEST_STR-ANPOE sy-vline
WA_RN2_BASEITEM_REQUEST_STR-ANFTY sy-vline
WA_RN2_BASEITEM_REQUEST_STR-GPART sy-vline
WA_RN2_BASEITEM_REQUEST_STR-KANAM sy-vline
WA_RN2_BASEITEM_REQUEST_STR-FRAGE sy-vline
WA_RN2_BASEITEM_REQUEST_STR-APRIE sy-vline
WA_RN2_BASEITEM_REQUEST_STR-ZWBGDT_OFF sy-vline
WA_RN2_BASEITEM_REQUEST_STR-WBGZT sy-vline
WA_RN2_BASEITEM_REQUEST_STR-SEL_SCREEN sy-vline
WA_RN2_BASEITEM_REQUEST_STR-SERVICE sy-vline
WA_RN2_BASEITEM_REQUEST_STR-NOCASE sy-vline
WA_RN2_BASEITEM_REQUEST_STR-USE_PROFILE sy-vline
WA_RN2_BASEITEM_REQUEST_STR-KANAM_LT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.