ABAP Select data from SAP table RN1MED_ME_QUANMOD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RN1MED_ME_QUANMOD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RN1MED_ME_QUANMOD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RN1MED_ME_QUANMOD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RN1MED_ME_QUANMOD TYPE STANDARD TABLE OF RN1MED_ME_QUANMOD,
      WA_RN1MED_ME_QUANMOD TYPE RN1MED_ME_QUANMOD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RN1MED_ME_QUANMOD> TYPE RN1MED_ME_QUANMOD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RN1MED_ME_QUANMOD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RN1MED_ME_QUANMOD
  INTO TABLE IT_RN1MED_ME_QUANMOD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RN1MED_ME_QUANMOD
*  INTO TABLE @DATA(IT_RN1MED_ME_QUANMOD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RN1MED_ME_QUANMOD INDEX 1 INTO DATA(WA_RN1MED_ME_QUANMOD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RN1MED_ME_QUANMOD ASSIGNING <RN1MED_ME_QUANMOD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RN1MED_ME_QUANMOD>-MANDT = 1.
<RN1MED_ME_QUANMOD>-QUANMODID = 1.
<RN1MED_ME_QUANMOD>-MEORDID = 1.
<RN1MED_ME_QUANMOD>-MEORDID_X = 1.
<RN1MED_ME_QUANMOD>-SEQID = 1.
ENDLOOP.

LOOP AT IT_RN1MED_ME_QUANMOD INTO WA_RN1MED_ME_QUANMOD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RN1MED_ME_QUANMOD-SEQID_X, sy-vline,
WA_RN1MED_ME_QUANMOD-TIME, sy-vline,
WA_RN1MED_ME_QUANMOD-TIME_X, sy-vline,
WA_RN1MED_ME_QUANMOD-DOSE, sy-vline,
WA_RN1MED_ME_QUANMOD-DOSE_X, sy-vline,
WA_RN1MED_ME_QUANMOD-UNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RN1MED_ME_QUANMOD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RN1MED_ME_QUANMOD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RN1MED_ME_QUANMOD INTO WA_RN1MED_ME_QUANMOD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ME12D, internal->external for field DOSE CALL FUNCTION 'CONVERSION_EXIT_ME12D_OUTPUT' EXPORTING input = WA_RN1MED_ME_QUANMOD-DOSE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1MED_ME_QUANMOD-DOSE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RN1MED_ME_QUANMOD_STR,
MANDT TYPE STRING,
QUANMODID TYPE STRING,
MEORDID TYPE STRING,
MEORDID_X TYPE STRING,
SEQID TYPE STRING,
SEQID_X TYPE STRING,
TIME TYPE STRING,
TIME_X TYPE STRING,
DOSE TYPE STRING,
DOSE_X TYPE STRING,
UNIT TYPE STRING,
UNIT_X TYPE STRING,
KZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_RN1MED_ME_QUANMOD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RN1MED_ME_QUANMOD_STR-MANDT sy-vline
WA_RN1MED_ME_QUANMOD_STR-QUANMODID sy-vline
WA_RN1MED_ME_QUANMOD_STR-MEORDID sy-vline
WA_RN1MED_ME_QUANMOD_STR-MEORDID_X sy-vline
WA_RN1MED_ME_QUANMOD_STR-SEQID sy-vline
WA_RN1MED_ME_QUANMOD_STR-SEQID_X sy-vline
WA_RN1MED_ME_QUANMOD_STR-TIME sy-vline
WA_RN1MED_ME_QUANMOD_STR-TIME_X sy-vline
WA_RN1MED_ME_QUANMOD_STR-DOSE sy-vline
WA_RN1MED_ME_QUANMOD_STR-DOSE_X sy-vline
WA_RN1MED_ME_QUANMOD_STR-UNIT sy-vline
WA_RN1MED_ME_QUANMOD_STR-UNIT_X sy-vline
WA_RN1MED_ME_QUANMOD_STR-KZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.