ABAP Select data from SAP table RN1ME_DYNP_ORDER_ADINFO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RN1ME_DYNP_ORDER_ADINFO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RN1ME_DYNP_ORDER_ADINFO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RN1ME_DYNP_ORDER_ADINFO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RN1ME_DYNP_ORDER_ADINFO TYPE STANDARD TABLE OF RN1ME_DYNP_ORDER_ADINFO,
      WA_RN1ME_DYNP_ORDER_ADINFO TYPE RN1ME_DYNP_ORDER_ADINFO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RN1ME_DYNP_ORDER_ADINFO> TYPE RN1ME_DYNP_ORDER_ADINFO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RN1ME_DYNP_ORDER_ADINFO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RN1ME_DYNP_ORDER_ADINFO
  INTO TABLE IT_RN1ME_DYNP_ORDER_ADINFO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RN1ME_DYNP_ORDER_ADINFO
*  INTO TABLE @DATA(IT_RN1ME_DYNP_ORDER_ADINFO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RN1ME_DYNP_ORDER_ADINFO INDEX 1 INTO DATA(WA_RN1ME_DYNP_ORDER_ADINFO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RN1ME_DYNP_ORDER_ADINFO ASSIGNING <RN1ME_DYNP_ORDER_ADINFO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RN1ME_DYNP_ORDER_ADINFO>-MEORDID = 1.
<RN1ME_DYNP_ORDER_ADINFO>-ORDTY = 1.
<RN1ME_DYNP_ORDER_ADINFO>-MORESP1 = 1.
<RN1ME_DYNP_ORDER_ADINFO>-ORDDEPOU = 1.
<RN1ME_DYNP_ORDER_ADINFO>-ORDOU = 1.
ENDLOOP.

LOOP AT IT_RN1ME_DYNP_ORDER_ADINFO INTO WA_RN1ME_DYNP_ORDER_ADINFO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RN1ME_DYNP_ORDER_ADINFO-ERGPART, sy-vline,
WA_RN1ME_DYNP_ORDER_ADINFO-ERDAT, sy-vline,
WA_RN1ME_DYNP_ORDER_ADINFO-ERTIM, sy-vline,
WA_RN1ME_DYNP_ORDER_ADINFO-ORDDEPOUDESCR, sy-vline,
WA_RN1ME_DYNP_ORDER_ADINFO-ORDOUDESCR, sy-vline,
WA_RN1ME_DYNP_ORDER_ADINFO-MORESP1DESCR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RN1ME_DYNP_ORDER_ADINFO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RN1ME_DYNP_ORDER_ADINFO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RN1ME_DYNP_ORDER_ADINFO INTO WA_RN1ME_DYNP_ORDER_ADINFO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field MORESP1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RN1ME_DYNP_ORDER_ADINFO-MORESP1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_DYNP_ORDER_ADINFO-MORESP1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ORDDEPOU CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RN1ME_DYNP_ORDER_ADINFO-ORDDEPOU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_DYNP_ORDER_ADINFO-ORDDEPOU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ORDOU CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RN1ME_DYNP_ORDER_ADINFO-ORDOU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1ME_DYNP_ORDER_ADINFO-ORDOU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RN1ME_DYNP_ORDER_ADINFO_STR,
MEORDID TYPE STRING,
ORDTY TYPE STRING,
MORESP1 TYPE STRING,
ORDDEPOU TYPE STRING,
ORDOU TYPE STRING,
ERGPART TYPE STRING,
ERDAT TYPE STRING,
ERTIM TYPE STRING,
ORDDEPOUDESCR TYPE STRING,
ORDOUDESCR TYPE STRING,
MORESP1DESCR TYPE STRING,
MOTYPIDDESCR TYPE STRING,
UNAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_RN1ME_DYNP_ORDER_ADINFO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RN1ME_DYNP_ORDER_ADINFO_STR-MEORDID sy-vline
WA_RN1ME_DYNP_ORDER_ADINFO_STR-ORDTY sy-vline
WA_RN1ME_DYNP_ORDER_ADINFO_STR-MORESP1 sy-vline
WA_RN1ME_DYNP_ORDER_ADINFO_STR-ORDDEPOU sy-vline
WA_RN1ME_DYNP_ORDER_ADINFO_STR-ORDOU sy-vline
WA_RN1ME_DYNP_ORDER_ADINFO_STR-ERGPART sy-vline
WA_RN1ME_DYNP_ORDER_ADINFO_STR-ERDAT sy-vline
WA_RN1ME_DYNP_ORDER_ADINFO_STR-ERTIM sy-vline
WA_RN1ME_DYNP_ORDER_ADINFO_STR-ORDDEPOUDESCR sy-vline
WA_RN1ME_DYNP_ORDER_ADINFO_STR-ORDOUDESCR sy-vline
WA_RN1ME_DYNP_ORDER_ADINFO_STR-MORESP1DESCR sy-vline
WA_RN1ME_DYNP_ORDER_ADINFO_STR-MOTYPIDDESCR sy-vline
WA_RN1ME_DYNP_ORDER_ADINFO_STR-UNAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.