ABAP Select data from SAP table RN1FOAGENTA_C into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RN1FOAGENTA_C table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RN1FOAGENTA_C. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RN1FOAGENTA_C table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RN1FOAGENTA_C TYPE STANDARD TABLE OF RN1FOAGENTA_C,
      WA_RN1FOAGENTA_C TYPE RN1FOAGENTA_C,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RN1FOAGENTA_C> TYPE RN1FOAGENTA_C.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RN1FOAGENTA_C.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RN1FOAGENTA_C
  INTO TABLE IT_RN1FOAGENTA_C.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RN1FOAGENTA_C
*  INTO TABLE @DATA(IT_RN1FOAGENTA_C2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RN1FOAGENTA_C INDEX 1 INTO DATA(WA_RN1FOAGENTA_C2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RN1FOAGENTA_C ASSIGNING <RN1FOAGENTA_C>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RN1FOAGENTA_C>-MANDT = 1.
<RN1FOAGENTA_C>-DRUGID = 1.
<RN1FOAGENTA_C>-AGENTID = 1.
<RN1FOAGENTA_C>-AGENTROLE = 1.
<RN1FOAGENTA_C>-UNIT = 1.
ENDLOOP.

LOOP AT IT_RN1FOAGENTA_C INTO WA_RN1FOAGENTA_C.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RN1FOAGENTA_C-STRGTH, sy-vline,
WA_RN1FOAGENTA_C-QUANT, sy-vline,
WA_RN1FOAGENTA_C-QUANTU, sy-vline,
WA_RN1FOAGENTA_C-ERDAT, sy-vline,
WA_RN1FOAGENTA_C-ERTIM, sy-vline,
WA_RN1FOAGENTA_C-ERUSR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RN1FOAGENTA_C you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RN1FOAGENTA_C TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RN1FOAGENTA_C INTO WA_RN1FOAGENTA_C. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RN1FOAGENTA_C-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1FOAGENTA_C-UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MEQUA, internal->external for field STRGTH CALL FUNCTION 'CONVERSION_EXIT_MEQUA_OUTPUT' EXPORTING input = WA_RN1FOAGENTA_C-STRGTH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1FOAGENTA_C-STRGTH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MEQUA, internal->external for field QUANT CALL FUNCTION 'CONVERSION_EXIT_MEQUA_OUTPUT' EXPORTING input = WA_RN1FOAGENTA_C-QUANT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1FOAGENTA_C-QUANT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUANTU CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RN1FOAGENTA_C-QUANTU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RN1FOAGENTA_C-QUANTU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RN1FOAGENTA_C_STR,
MANDT TYPE STRING,
DRUGID TYPE STRING,
AGENTID TYPE STRING,
AGENTROLE TYPE STRING,
UNIT TYPE STRING,
STRGTH TYPE STRING,
QUANT TYPE STRING,
QUANTU TYPE STRING,
ERDAT TYPE STRING,
ERTIM TYPE STRING,
ERUSR TYPE STRING,
UPDAT TYPE STRING,
UPTIM TYPE STRING,
UPUSR TYPE STRING,
UNIT_X TYPE STRING,
STRGTH_X TYPE STRING,
QUANT_X TYPE STRING,
QUANTU_X TYPE STRING,END OF T_EKKO_STR. DATA: WA_RN1FOAGENTA_C_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RN1FOAGENTA_C_STR-MANDT sy-vline
WA_RN1FOAGENTA_C_STR-DRUGID sy-vline
WA_RN1FOAGENTA_C_STR-AGENTID sy-vline
WA_RN1FOAGENTA_C_STR-AGENTROLE sy-vline
WA_RN1FOAGENTA_C_STR-UNIT sy-vline
WA_RN1FOAGENTA_C_STR-STRGTH sy-vline
WA_RN1FOAGENTA_C_STR-QUANT sy-vline
WA_RN1FOAGENTA_C_STR-QUANTU sy-vline
WA_RN1FOAGENTA_C_STR-ERDAT sy-vline
WA_RN1FOAGENTA_C_STR-ERTIM sy-vline
WA_RN1FOAGENTA_C_STR-ERUSR sy-vline
WA_RN1FOAGENTA_C_STR-UPDAT sy-vline
WA_RN1FOAGENTA_C_STR-UPTIM sy-vline
WA_RN1FOAGENTA_C_STR-UPUSR sy-vline
WA_RN1FOAGENTA_C_STR-UNIT_X sy-vline
WA_RN1FOAGENTA_C_STR-STRGTH_X sy-vline
WA_RN1FOAGENTA_C_STR-QUANT_X sy-vline
WA_RN1FOAGENTA_C_STR-QUANTU_X sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.