ABAP Select data from SAP table RN1_BC_DYNP_CHEAD_RES into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RN1_BC_DYNP_CHEAD_RES table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RN1_BC_DYNP_CHEAD_RES. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RN1_BC_DYNP_CHEAD_RES table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RN1_BC_DYNP_CHEAD_RES TYPE STANDARD TABLE OF RN1_BC_DYNP_CHEAD_RES,
      WA_RN1_BC_DYNP_CHEAD_RES TYPE RN1_BC_DYNP_CHEAD_RES,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RN1_BC_DYNP_CHEAD_RES> TYPE RN1_BC_DYNP_CHEAD_RES.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RN1_BC_DYNP_CHEAD_RES.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RN1_BC_DYNP_CHEAD_RES
  INTO TABLE IT_RN1_BC_DYNP_CHEAD_RES.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RN1_BC_DYNP_CHEAD_RES
*  INTO TABLE @DATA(IT_RN1_BC_DYNP_CHEAD_RES2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RN1_BC_DYNP_CHEAD_RES INDEX 1 INTO DATA(WA_RN1_BC_DYNP_CHEAD_RES2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RN1_BC_DYNP_CHEAD_RES ASSIGNING <RN1_BC_DYNP_CHEAD_RES>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RN1_BC_DYNP_CHEAD_RES>-MANDT = 1.
<RN1_BC_DYNP_CHEAD_RES>-BCHID = 1.
<RN1_BC_DYNP_CHEAD_RES>-BCTYPEID = 1.
<RN1_BC_DYNP_CHEAD_RES>-EXTID = 1.
<RN1_BC_DYNP_CHEAD_RES>-ICON = 1.
ENDLOOP.

LOOP AT IT_RN1_BC_DYNP_CHEAD_RES INTO WA_RN1_BC_DYNP_CHEAD_RES.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RN1_BC_DYNP_CHEAD_RES-GROUP_ICON, sy-vline,
WA_RN1_BC_DYNP_CHEAD_RES-LEAF_ICON, sy-vline,
WA_RN1_BC_DYNP_CHEAD_RES-ERDAT, sy-vline,
WA_RN1_BC_DYNP_CHEAD_RES-ERTIM, sy-vline,
WA_RN1_BC_DYNP_CHEAD_RES-ERUSR, sy-vline,
WA_RN1_BC_DYNP_CHEAD_RES-UPDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RN1_BC_DYNP_CHEAD_RES you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RN1_BC_DYNP_CHEAD_RES TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RN1_BC_DYNP_CHEAD_RES INTO WA_RN1_BC_DYNP_CHEAD_RES. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RN1_BC_DYNP_CHEAD_RES_STR,
MANDT TYPE STRING,
BCHID TYPE STRING,
BCTYPEID TYPE STRING,
EXTID TYPE STRING,
ICON TYPE STRING,
GROUP_ICON TYPE STRING,
LEAF_ICON TYPE STRING,
ERDAT TYPE STRING,
ERTIM TYPE STRING,
ERUSR TYPE STRING,
UPDAT TYPE STRING,
UPTIM TYPE STRING,
UPUSR TYPE STRING,
LOEKZ TYPE STRING,
LODAT TYPE STRING,
LOTIM TYPE STRING,
LOUSR TYPE STRING,
TIMESTAMP TYPE STRING,
BCHNAME TYPE STRING,
BCHDESCRIPTION TYPE STRING,
DUMMY TYPE STRING,
BCTYPENAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_RN1_BC_DYNP_CHEAD_RES_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-MANDT sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-BCHID sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-BCTYPEID sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-EXTID sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-ICON sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-GROUP_ICON sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-LEAF_ICON sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-ERDAT sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-ERTIM sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-ERUSR sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-UPDAT sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-UPTIM sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-UPUSR sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-LOEKZ sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-LODAT sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-LOTIM sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-LOUSR sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-TIMESTAMP sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-BCHNAME sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-BCHDESCRIPTION sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-DUMMY sy-vline
WA_RN1_BC_DYNP_CHEAD_RES_STR-BCTYPENAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.