ABAP Select data from SAP table RMXTS_SAMPLE_RESULTS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RMXTS_SAMPLE_RESULTS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RMXTS_SAMPLE_RESULTS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RMXTS_SAMPLE_RESULTS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RMXTS_SAMPLE_RESULTS TYPE STANDARD TABLE OF RMXTS_SAMPLE_RESULTS,
      WA_RMXTS_SAMPLE_RESULTS TYPE RMXTS_SAMPLE_RESULTS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RMXTS_SAMPLE_RESULTS> TYPE RMXTS_SAMPLE_RESULTS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RMXTS_SAMPLE_RESULTS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RMXTS_SAMPLE_RESULTS
  INTO TABLE IT_RMXTS_SAMPLE_RESULTS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RMXTS_SAMPLE_RESULTS
*  INTO TABLE @DATA(IT_RMXTS_SAMPLE_RESULTS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RMXTS_SAMPLE_RESULTS INDEX 1 INTO DATA(WA_RMXTS_SAMPLE_RESULTS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RMXTS_SAMPLE_RESULTS ASSIGNING <RMXTS_SAMPLE_RESULTS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RMXTS_SAMPLE_RESULTS>-INSPLOT = 1.
<RMXTS_SAMPLE_RESULTS>-INSPOPER = 1.
<RMXTS_SAMPLE_RESULTS>-INSPCHAR = 1.
<RMXTS_SAMPLE_RESULTS>-INSPSAMPLE = 1.
<RMXTS_SAMPLE_RESULTS>-LAST_SMPL = 1.
ENDLOOP.

LOOP AT IT_RMXTS_SAMPLE_RESULTS INTO WA_RMXTS_SAMPLE_RESULTS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RMXTS_SAMPLE_RESULTS-CLOSED, sy-vline,
WA_RMXTS_SAMPLE_RESULTS-EVALUATED, sy-vline,
WA_RMXTS_SAMPLE_RESULTS-SMPL_ATTR, sy-vline,
WA_RMXTS_SAMPLE_RESULTS-SMPL_INVAL, sy-vline,
WA_RMXTS_SAMPLE_RESULTS-EVALUATION, sy-vline,
WA_RMXTS_SAMPLE_RESULTS-ERR_CLASS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RMXTS_SAMPLE_RESULTS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RMXTS_SAMPLE_RESULTS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RMXTS_SAMPLE_RESULTS INTO WA_RMXTS_SAMPLE_RESULTS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INSPLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RMXTS_SAMPLE_RESULTS-INSPLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RMXTS_SAMPLE_RESULTS-INSPLOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field INSPOPER CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_RMXTS_SAMPLE_RESULTS-INSPOPER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RMXTS_SAMPLE_RESULTS-INSPOPER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADD_INFO1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RMXTS_SAMPLE_RESULTS-ADD_INFO1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RMXTS_SAMPLE_RESULTS-ADD_INFO1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field METHOD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RMXTS_SAMPLE_RESULTS-METHOD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RMXTS_SAMPLE_RESULTS-METHOD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRIALID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RMXTS_SAMPLE_RESULTS-TRIALID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RMXTS_SAMPLE_RESULTS-TRIALID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QMNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RMXTS_SAMPLE_RESULTS-QMNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RMXTS_SAMPLE_RESULTS-QMNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PHYNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RMXTS_SAMPLE_RESULTS-PHYNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RMXTS_SAMPLE_RESULTS-PHYNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RMXTS_SAMPLE_RESULTS_STR,
INSPLOT TYPE STRING,
INSPOPER TYPE STRING,
INSPCHAR TYPE STRING,
INSPSAMPLE TYPE STRING,
LAST_SMPL TYPE STRING,
CLOSED TYPE STRING,
EVALUATED TYPE STRING,
SMPL_ATTR TYPE STRING,
SMPL_INVAL TYPE STRING,
EVALUATION TYPE STRING,
ERR_CLASS TYPE STRING,
VALID_VALS TYPE STRING,
NONCONF TYPE STRING,
DEFECTS TYPE STRING,
VALS_ABOVE TYPE STRING,
VALS_BELOW TYPE STRING,
MEAN_VALUE TYPE STRING,
VARIANCE TYPE STRING,
MAXIMUM TYPE STRING,
MINIMUM TYPE STRING,
START_DATE TYPE STRING,
START_TIME TYPE STRING,
END_DATE TYPE STRING,
END_TIME TYPE STRING,
INSPECTOR TYPE STRING,
RES_ORG TYPE STRING,
REMARK TYPE STRING,
CODE1 TYPE STRING,
CODE_GRP1 TYPE STRING,
CODE2 TYPE STRING,
CODE_GRP2 TYPE STRING,
CODE3 TYPE STRING,
CODE_GRP3 TYPE STRING,
CODE4 TYPE STRING,
CODE_GRP4 TYPE STRING,
CODE5 TYPE STRING,
CODE_GRP5 TYPE STRING,
ORIGINAL_INPUT TYPE STRING,
INPPROC_READY TYPE STRING,
DIFF_DEC_PLACES TYPE STRING,
ADD_INFO1 TYPE STRING,
ADD_INFO2 TYPE STRING,
CONDITION_ACTIVE TYPE STRING,
CLOSE_SAMPLE_ONLY TYPE STRING,
KTEXTLOS TYPE STRING,
CHAR_DESCR TYPE STRING,
METHOD TYPE STRING,
METHOD_TXT TYPE STRING,
MEAS_UNIT TYPE STRING,
MEAS_UNITT TYPE STRING,
MSEHT TYPE STRING,
TARGET_VAL TYPE STRING,
UP_TOL_LMT TYPE STRING,
LW_TOL_LMT TYPE STRING,
CODE_TXT1 TYPE STRING,
CODE_TXT2 TYPE STRING,
CODE_TXT3 TYPE STRING,
CODE_TXT4 TYPE STRING,
CODE_TXT5 TYPE STRING,
HERKUNFT TYPE STRING,
TXT_OPER TYPE STRING,
TRIALID TYPE STRING,
LINEMODE TYPE STRING,
QMNUM TYPE STRING,
QMTXT TYPE STRING,
STABICON TYPE STRING,
STABICONTXT TYPE STRING,
PHYNR TYPE STRING,
PRARTKTXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_RMXTS_SAMPLE_RESULTS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-INSPLOT sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-INSPOPER sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-INSPCHAR sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-INSPSAMPLE sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-LAST_SMPL sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CLOSED sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-EVALUATED sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-SMPL_ATTR sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-SMPL_INVAL sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-EVALUATION sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-ERR_CLASS sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-VALID_VALS sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-NONCONF sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-DEFECTS sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-VALS_ABOVE sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-VALS_BELOW sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-MEAN_VALUE sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-VARIANCE sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-MAXIMUM sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-MINIMUM sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-START_DATE sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-START_TIME sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-END_DATE sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-END_TIME sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-INSPECTOR sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-RES_ORG sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-REMARK sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CODE1 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CODE_GRP1 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CODE2 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CODE_GRP2 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CODE3 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CODE_GRP3 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CODE4 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CODE_GRP4 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CODE5 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CODE_GRP5 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-ORIGINAL_INPUT sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-INPPROC_READY sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-DIFF_DEC_PLACES sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-ADD_INFO1 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-ADD_INFO2 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CONDITION_ACTIVE sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CLOSE_SAMPLE_ONLY sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-KTEXTLOS sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CHAR_DESCR sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-METHOD sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-METHOD_TXT sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-MEAS_UNIT sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-MEAS_UNITT sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-MSEHT sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-TARGET_VAL sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-UP_TOL_LMT sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-LW_TOL_LMT sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CODE_TXT1 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CODE_TXT2 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CODE_TXT3 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CODE_TXT4 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-CODE_TXT5 sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-HERKUNFT sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-TXT_OPER sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-TRIALID sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-LINEMODE sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-QMNUM sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-QMTXT sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-STABICON sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-STABICONTXT sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-PHYNR sy-vline
WA_RMXTS_SAMPLE_RESULTS_STR-PRARTKTXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.