ABAP Select data from SAP table RMXTS_FRML_TOOL_KEY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RMXTS_FRML_TOOL_KEY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RMXTS_FRML_TOOL_KEY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RMXTS_FRML_TOOL_KEY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RMXTS_FRML_TOOL_KEY TYPE STANDARD TABLE OF RMXTS_FRML_TOOL_KEY,
      WA_RMXTS_FRML_TOOL_KEY TYPE RMXTS_FRML_TOOL_KEY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RMXTS_FRML_TOOL_KEY> TYPE RMXTS_FRML_TOOL_KEY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RMXTS_FRML_TOOL_KEY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RMXTS_FRML_TOOL_KEY
  INTO TABLE IT_RMXTS_FRML_TOOL_KEY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RMXTS_FRML_TOOL_KEY
*  INTO TABLE @DATA(IT_RMXTS_FRML_TOOL_KEY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RMXTS_FRML_TOOL_KEY INDEX 1 INTO DATA(WA_RMXTS_FRML_TOOL_KEY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RMXTS_FRML_TOOL_KEY ASSIGNING <RMXTS_FRML_TOOL_KEY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RMXTS_FRML_TOOL_KEY>-STAGE = 1.
<RMXTS_FRML_TOOL_KEY>-USE_TYPE = 1.
<RMXTS_FRML_TOOL_KEY>-MATNR = 1.
<RMXTS_FRML_TOOL_KEY>-STREAM_DEST = 1.
<RMXTS_FRML_TOOL_KEY>-SUBID = 1.
ENDLOOP.

LOOP AT IT_RMXTS_FRML_TOOL_KEY INTO WA_RMXTS_FRML_TOOL_KEY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RMXTS_FRML_TOOL_KEY-OPERATION, sy-vline,
WA_RMXTS_FRML_TOOL_KEY-ACTION, sy-vline,
WA_RMXTS_FRML_TOOL_KEY-ROLE, sy-vline,
WA_RMXTS_FRML_TOOL_KEY-SORTNR, sy-vline,
WA_RMXTS_FRML_TOOL_KEY-UNIT, sy-vline,
WA_RMXTS_FRML_TOOL_KEY-CHARGE_NR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RMXTS_FRML_TOOL_KEY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RMXTS_FRML_TOOL_KEY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RMXTS_FRML_TOOL_KEY INTO WA_RMXTS_FRML_TOOL_KEY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RMXTS_FRML_TOOL_KEY-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RMXTS_FRML_TOOL_KEY-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SPEC1, internal->external for field SUBID CALL FUNCTION 'CONVERSION_EXIT_SPEC1_OUTPUT' EXPORTING input = WA_RMXTS_FRML_TOOL_KEY-SUBID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RMXTS_FRML_TOOL_KEY-SUBID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RMXTS_FRML_TOOL_KEY-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RMXTS_FRML_TOOL_KEY-UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RMXTS_FRML_TOOL_KEY_STR,
STAGE TYPE STRING,
USE_TYPE TYPE STRING,
MATNR TYPE STRING,
STREAM_DEST TYPE STRING,
SUBID TYPE STRING,
OPERATION TYPE STRING,
ACTION TYPE STRING,
ROLE TYPE STRING,
SORTNR TYPE STRING,
UNIT TYPE STRING,
CHARGE_NR TYPE STRING,END OF T_EKKO_STR. DATA: WA_RMXTS_FRML_TOOL_KEY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RMXTS_FRML_TOOL_KEY_STR-STAGE sy-vline
WA_RMXTS_FRML_TOOL_KEY_STR-USE_TYPE sy-vline
WA_RMXTS_FRML_TOOL_KEY_STR-MATNR sy-vline
WA_RMXTS_FRML_TOOL_KEY_STR-STREAM_DEST sy-vline
WA_RMXTS_FRML_TOOL_KEY_STR-SUBID sy-vline
WA_RMXTS_FRML_TOOL_KEY_STR-OPERATION sy-vline
WA_RMXTS_FRML_TOOL_KEY_STR-ACTION sy-vline
WA_RMXTS_FRML_TOOL_KEY_STR-ROLE sy-vline
WA_RMXTS_FRML_TOOL_KEY_STR-SORTNR sy-vline
WA_RMXTS_FRML_TOOL_KEY_STR-UNIT sy-vline
WA_RMXTS_FRML_TOOL_KEY_STR-CHARGE_NR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.