ABAP Select data from SAP table RMSAV_SUBOBJECT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RMSAV_SUBOBJECT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RMSAV_SUBOBJECT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RMSAV_SUBOBJECT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RMSAV_SUBOBJECT TYPE STANDARD TABLE OF RMSAV_SUBOBJECT,
      WA_RMSAV_SUBOBJECT TYPE RMSAV_SUBOBJECT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RMSAV_SUBOBJECT> TYPE RMSAV_SUBOBJECT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RMSAV_SUBOBJECT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RMSAV_SUBOBJECT
  INTO TABLE IT_RMSAV_SUBOBJECT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RMSAV_SUBOBJECT
*  INTO TABLE @DATA(IT_RMSAV_SUBOBJECT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RMSAV_SUBOBJECT INDEX 1 INTO DATA(WA_RMSAV_SUBOBJECT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RMSAV_SUBOBJECT ASSIGNING <RMSAV_SUBOBJECT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RMSAV_SUBOBJECT>-MANDT = 1.
<RMSAV_SUBOBJECT>-OBJECTTYPE = 1.
<RMSAV_SUBOBJECT>-OBJSUBTYPE = 1.
<RMSAV_SUBOBJECT>-OBJSUBTYPET = 1.
<RMSAV_SUBOBJECT>-VRS_FLG_GAP = 1.
ENDLOOP.

LOOP AT IT_RMSAV_SUBOBJECT INTO WA_RMSAV_SUBOBJECT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RMSAV_SUBOBJECT-VRS_FLG_OLP, sy-vline,
WA_RMSAV_SUBOBJECT-VRS_TYPE, sy-vline,
WA_RMSAV_SUBOBJECT-FLG_INS, sy-vline,
WA_RMSAV_SUBOBJECT-IN_NRRANGE, sy-vline,
WA_RMSAV_SUBOBJECT-EX_NRRANGE, sy-vline,
WA_RMSAV_SUBOBJECT-PRE_LEN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RMSAV_SUBOBJECT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RMSAV_SUBOBJECT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RMSAV_SUBOBJECT INTO WA_RMSAV_SUBOBJECT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RMSAV_SUBOBJECT_STR,
MANDT TYPE STRING,
OBJECTTYPE TYPE STRING,
OBJSUBTYPE TYPE STRING,
OBJSUBTYPET TYPE STRING,
VRS_FLG_GAP TYPE STRING,
VRS_FLG_OLP TYPE STRING,
VRS_TYPE TYPE STRING,
FLG_INS TYPE STRING,
IN_NRRANGE TYPE STRING,
EX_NRRANGE TYPE STRING,
PRE_LEN TYPE STRING,
SEPARATOR_PV TYPE STRING,
VRS_LEN TYPE STRING,
SEPARATOR_VD TYPE STRING,
DFT_LEN TYPE STRING,END OF T_EKKO_STR. DATA: WA_RMSAV_SUBOBJECT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RMSAV_SUBOBJECT_STR-MANDT sy-vline
WA_RMSAV_SUBOBJECT_STR-OBJECTTYPE sy-vline
WA_RMSAV_SUBOBJECT_STR-OBJSUBTYPE sy-vline
WA_RMSAV_SUBOBJECT_STR-OBJSUBTYPET sy-vline
WA_RMSAV_SUBOBJECT_STR-VRS_FLG_GAP sy-vline
WA_RMSAV_SUBOBJECT_STR-VRS_FLG_OLP sy-vline
WA_RMSAV_SUBOBJECT_STR-VRS_TYPE sy-vline
WA_RMSAV_SUBOBJECT_STR-FLG_INS sy-vline
WA_RMSAV_SUBOBJECT_STR-IN_NRRANGE sy-vline
WA_RMSAV_SUBOBJECT_STR-EX_NRRANGE sy-vline
WA_RMSAV_SUBOBJECT_STR-PRE_LEN sy-vline
WA_RMSAV_SUBOBJECT_STR-SEPARATOR_PV sy-vline
WA_RMSAV_SUBOBJECT_STR-VRS_LEN sy-vline
WA_RMSAV_SUBOBJECT_STR-SEPARATOR_VD sy-vline
WA_RMSAV_SUBOBJECT_STR-DFT_LEN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.