ABAP Select data from SAP table RMSAS_APPLOG_BUFFER into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RMSAS_APPLOG_BUFFER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RMSAS_APPLOG_BUFFER. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RMSAS_APPLOG_BUFFER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RMSAS_APPLOG_BUFFER TYPE STANDARD TABLE OF RMSAS_APPLOG_BUFFER,
      WA_RMSAS_APPLOG_BUFFER TYPE RMSAS_APPLOG_BUFFER,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RMSAS_APPLOG_BUFFER> TYPE RMSAS_APPLOG_BUFFER.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RMSAS_APPLOG_BUFFER.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RMSAS_APPLOG_BUFFER
  INTO TABLE IT_RMSAS_APPLOG_BUFFER.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RMSAS_APPLOG_BUFFER
*  INTO TABLE @DATA(IT_RMSAS_APPLOG_BUFFER2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RMSAS_APPLOG_BUFFER INDEX 1 INTO DATA(WA_RMSAS_APPLOG_BUFFER2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RMSAS_APPLOG_BUFFER ASSIGNING <RMSAS_APPLOG_BUFFER>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RMSAS_APPLOG_BUFFER>-LOG = 1.
<RMSAS_APPLOG_BUFFER>-EXTNUMBER = 1.
<RMSAS_APPLOG_BUFFER>-OBJECT = 1.
<RMSAS_APPLOG_BUFFER>-SUBOBJECT = 1.
<RMSAS_APPLOG_BUFFER>-ALDATE = 1.
ENDLOOP.

LOOP AT IT_RMSAS_APPLOG_BUFFER INTO WA_RMSAS_APPLOG_BUFFER.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RMSAS_APPLOG_BUFFER-ALTIME, sy-vline,
WA_RMSAS_APPLOG_BUFFER-ALUSER, sy-vline,
WA_RMSAS_APPLOG_BUFFER-ALTCODE, sy-vline,
WA_RMSAS_APPLOG_BUFFER-ALPROG, sy-vline,
WA_RMSAS_APPLOG_BUFFER-ALMODE, sy-vline,
WA_RMSAS_APPLOG_BUFFER-ALCHDATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RMSAS_APPLOG_BUFFER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RMSAS_APPLOG_BUFFER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RMSAS_APPLOG_BUFFER INTO WA_RMSAS_APPLOG_BUFFER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RMSAS_APPLOG_BUFFER_STR,
LOG TYPE STRING,
EXTNUMBER TYPE STRING,
OBJECT TYPE STRING,
SUBOBJECT TYPE STRING,
ALDATE TYPE STRING,
ALTIME TYPE STRING,
ALUSER TYPE STRING,
ALTCODE TYPE STRING,
ALPROG TYPE STRING,
ALMODE TYPE STRING,
ALCHDATE TYPE STRING,
ALCHTIME TYPE STRING,
ALCHUSER TYPE STRING,
ALDATE_DEL TYPE STRING,
DEL_BEFORE TYPE STRING,
ALSTATE TYPE STRING,
CONTEXT TYPE STRING,
TABNAME TYPE STRING,
VALUE TYPE STRING,
PARAMS TYPE STRING,
T_PAR TYPE STRING,
CALLBACK TYPE STRING,
USEREXITP TYPE STRING,
USEREXITF TYPE STRING,
USEREXITT TYPE STRING,
ALTEXT TYPE STRING,
HANDLE TYPE STRING,END OF T_EKKO_STR. DATA: WA_RMSAS_APPLOG_BUFFER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-LOG sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-EXTNUMBER sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-OBJECT sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-SUBOBJECT sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-ALDATE sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-ALTIME sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-ALUSER sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-ALTCODE sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-ALPROG sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-ALMODE sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-ALCHDATE sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-ALCHTIME sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-ALCHUSER sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-ALDATE_DEL sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-DEL_BEFORE sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-ALSTATE sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-CONTEXT sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-TABNAME sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-VALUE sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-PARAMS sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-T_PAR sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-CALLBACK sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-USEREXITP sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-USEREXITF sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-USEREXITT sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-ALTEXT sy-vline
WA_RMSAS_APPLOG_BUFFER_STR-HANDLE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.