ABAP Select data from SAP table RMF64C220 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RMF64C220 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RMF64C220. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RMF64C220 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RMF64C220 TYPE STANDARD TABLE OF RMF64C220,
      WA_RMF64C220 TYPE RMF64C220,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RMF64C220> TYPE RMF64C220.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RMF64C220.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RMF64C220
  INTO TABLE IT_RMF64C220.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RMF64C220
*  INTO TABLE @DATA(IT_RMF64C2202).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RMF64C220 INDEX 1 INTO DATA(WA_RMF64C2202).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RMF64C220 ASSIGNING <RMF64C220>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RMF64C220>-RLDEPO = 1.
<RMF64C220>-XLDEPO = 1.
<RMF64C220>-ABEZ = 1.
<RMF64C220>-ASTUECK = 1.
<RMF64C220>-SEINBU = 1.
ENDLOOP.

LOOP AT IT_RMF64C220 INTO WA_RMF64C220.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RMF64C220-BJUNGWERT, sy-vline,
WA_RMF64C220-SEJWHR, sy-vline,
WA_RMF64C220-BJUNGWERTD, sy-vline,
WA_RMF64C220-AREST, sy-vline,
WA_RMF64C220-EBJUNGWERT, sy-vline,
WA_RMF64C220-EBJUNGWDEP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RMF64C220 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RMF64C220 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RMF64C220 INTO WA_RMF64C220. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit EXCRT, internal->external for field BFWANKURS CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_RMF64C220-BFWANKURS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RMF64C220-BFWANKURS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field BFWBUKURS CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_RMF64C220-BFWBUKURS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RMF64C220-BFWBUKURS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RMF64C220_STR,
RLDEPO TYPE STRING,
XLDEPO TYPE STRING,
ABEZ TYPE STRING,
ASTUECK TYPE STRING,
SEINBU TYPE STRING,
BJUNGWERT TYPE STRING,
SEJWHR TYPE STRING,
BJUNGWERTD TYPE STRING,
AREST TYPE STRING,
EBJUNGWERT TYPE STRING,
EBJUNGWDEP TYPE STRING,
SHJWHR TYPE STRING,
BFWANKURS TYPE STRING,
BFWBUKURS TYPE STRING,
RLDEPO_SUB TYPE STRING,
SZUSBEW TYPE STRING,
JZUSBEW TYPE STRING,END OF T_EKKO_STR. DATA: WA_RMF64C220_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RMF64C220_STR-RLDEPO sy-vline
WA_RMF64C220_STR-XLDEPO sy-vline
WA_RMF64C220_STR-ABEZ sy-vline
WA_RMF64C220_STR-ASTUECK sy-vline
WA_RMF64C220_STR-SEINBU sy-vline
WA_RMF64C220_STR-BJUNGWERT sy-vline
WA_RMF64C220_STR-SEJWHR sy-vline
WA_RMF64C220_STR-BJUNGWERTD sy-vline
WA_RMF64C220_STR-AREST sy-vline
WA_RMF64C220_STR-EBJUNGWERT sy-vline
WA_RMF64C220_STR-EBJUNGWDEP sy-vline
WA_RMF64C220_STR-SHJWHR sy-vline
WA_RMF64C220_STR-BFWANKURS sy-vline
WA_RMF64C220_STR-BFWBUKURS sy-vline
WA_RMF64C220_STR-RLDEPO_SUB sy-vline
WA_RMF64C220_STR-SZUSBEW sy-vline
WA_RMF64C220_STR-JZUSBEW sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.