ABAP Select data from SAP table RM11K into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RM11K table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RM11K. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RM11K table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RM11K TYPE STANDARD TABLE OF RM11K,
      WA_RM11K TYPE RM11K,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RM11K> TYPE RM11K.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RM11K.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RM11K
  INTO TABLE IT_RM11K.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RM11K
*  INTO TABLE @DATA(IT_RM11K2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RM11K INDEX 1 INTO DATA(WA_RM11K2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RM11K ASSIGNING <RM11K>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RM11K>-ERGKZ = 1.
<RM11K>-MKNTM = 1.
<RM11K>-MKNTW = 1.
<RM11K>-VRTKZ = 1.
<RM11K>-DIRTY_KZ = 1.
ENDLOOP.

LOOP AT IT_RM11K INTO WA_RM11K.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RM11K-BUKRS, sy-vline,
WA_RM11K-TWRKZ, sy-vline,
WA_RM11K-KWHKZ, sy-vline,
WA_RM11K-KWH_EXTROW, sy-vline,
WA_RM11K-KNTTP, sy-vline,
WA_RM11K-LVWERT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RM11K you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RM11K TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RM11K INTO WA_RM11K. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_RM11K-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RM11K-VORNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RM11K_STR,
ERGKZ TYPE STRING,
MKNTM TYPE STRING,
MKNTW TYPE STRING,
VRTKZ TYPE STRING,
DIRTY_KZ TYPE STRING,
BUKRS TYPE STRING,
TWRKZ TYPE STRING,
KWHKZ TYPE STRING,
KWH_EXTROW TYPE STRING,
KNTTP TYPE STRING,
LVWERT TYPE STRING,
WAERS TYPE STRING,
REF_AKTIND TYPE STRING,
VORNR TYPE STRING,
NETWR TYPE STRING,
MEASURE TYPE STRING,END OF T_EKKO_STR. DATA: WA_RM11K_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RM11K_STR-ERGKZ sy-vline
WA_RM11K_STR-MKNTM sy-vline
WA_RM11K_STR-MKNTW sy-vline
WA_RM11K_STR-VRTKZ sy-vline
WA_RM11K_STR-DIRTY_KZ sy-vline
WA_RM11K_STR-BUKRS sy-vline
WA_RM11K_STR-TWRKZ sy-vline
WA_RM11K_STR-KWHKZ sy-vline
WA_RM11K_STR-KWH_EXTROW sy-vline
WA_RM11K_STR-KNTTP sy-vline
WA_RM11K_STR-LVWERT sy-vline
WA_RM11K_STR-WAERS sy-vline
WA_RM11K_STR-REF_AKTIND sy-vline
WA_RM11K_STR-VORNR sy-vline
WA_RM11K_STR-NETWR sy-vline
WA_RM11K_STR-MEASURE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.