ABAP Select data from SAP table RLMFWOLCM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RLMFWOLCM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RLMFWOLCM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RLMFWOLCM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RLMFWOLCM TYPE STANDARD TABLE OF RLMFWOLCM,
      WA_RLMFWOLCM TYPE RLMFWOLCM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RLMFWOLCM> TYPE RLMFWOLCM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RLMFWOLCM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RLMFWOLCM
  INTO TABLE IT_RLMFWOLCM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RLMFWOLCM
*  INTO TABLE @DATA(IT_RLMFWOLCM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RLMFWOLCM INDEX 1 INTO DATA(WA_RLMFWOLCM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RLMFWOLCM ASSIGNING <RLMFWOLCM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RLMFWOLCM>-MANDT = 1.
<RLMFWOLCM>-RONUM = 1.
<RLMFWOLCM>-LOGSYS = 1.
<RLMFWOLCM>-OBJTYP = 1.
<RLMFWOLCM>-OBJKEY = 1.
ENDLOOP.

LOOP AT IT_RLMFWOLCM INTO WA_RLMFWOLCM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RLMFWOLCM-TARGET, sy-vline,
WA_RLMFWOLCM-CHKID, sy-vline,
WA_RLMFWOLCM-MSGNUM, sy-vline,
WA_RLMFWOLCM-MSGTY, sy-vline,
WA_RLMFWOLCM-MSGID, sy-vline,
WA_RLMFWOLCM-MSGNO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RLMFWOLCM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RLMFWOLCM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RLMFWOLCM INTO WA_RLMFWOLCM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RONUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RLMFWOLCM-RONUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RLMFWOLCM-RONUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RLMFWOLCM-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RLMFWOLCM-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OBJTYP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RLMFWOLCM-OBJTYP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RLMFWOLCM-OBJTYP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RLMFWOLCM_STR,
MANDT TYPE STRING,
RONUM TYPE STRING,
LOGSYS TYPE STRING,
OBJTYP TYPE STRING,
OBJKEY TYPE STRING,
TARGET TYPE STRING,
CHKID TYPE STRING,
MSGNUM TYPE STRING,
MSGTY TYPE STRING,
MSGID TYPE STRING,
MSGNO TYPE STRING,
MSGV1 TYPE STRING,
MSGV2 TYPE STRING,
MSGV3 TYPE STRING,
MSGV4 TYPE STRING,END OF T_EKKO_STR. DATA: WA_RLMFWOLCM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RLMFWOLCM_STR-MANDT sy-vline
WA_RLMFWOLCM_STR-RONUM sy-vline
WA_RLMFWOLCM_STR-LOGSYS sy-vline
WA_RLMFWOLCM_STR-OBJTYP sy-vline
WA_RLMFWOLCM_STR-OBJKEY sy-vline
WA_RLMFWOLCM_STR-TARGET sy-vline
WA_RLMFWOLCM_STR-CHKID sy-vline
WA_RLMFWOLCM_STR-MSGNUM sy-vline
WA_RLMFWOLCM_STR-MSGTY sy-vline
WA_RLMFWOLCM_STR-MSGID sy-vline
WA_RLMFWOLCM_STR-MSGNO sy-vline
WA_RLMFWOLCM_STR-MSGV1 sy-vline
WA_RLMFWOLCM_STR-MSGV2 sy-vline
WA_RLMFWOLCM_STR-MSGV3 sy-vline
WA_RLMFWOLCM_STR-MSGV4 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.