ABAP Select data from SAP table RLMFW_S_OL_CD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RLMFW_S_OL_CD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RLMFW_S_OL_CD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RLMFW_S_OL_CD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RLMFW_S_OL_CD TYPE STANDARD TABLE OF RLMFW_S_OL_CD,
      WA_RLMFW_S_OL_CD TYPE RLMFW_S_OL_CD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RLMFW_S_OL_CD> TYPE RLMFW_S_OL_CD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RLMFW_S_OL_CD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RLMFW_S_OL_CD
  INTO TABLE IT_RLMFW_S_OL_CD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RLMFW_S_OL_CD
*  INTO TABLE @DATA(IT_RLMFW_S_OL_CD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RLMFW_S_OL_CD INDEX 1 INTO DATA(WA_RLMFW_S_OL_CD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RLMFW_S_OL_CD ASSIGNING <RLMFW_S_OL_CD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RLMFW_S_OL_CD>-MANDT = 1.
<RLMFW_S_OL_CD>-RONUM = 1.
<RLMFW_S_OL_CD>-LOGSYS = 1.
<RLMFW_S_OL_CD>-OBJTYP = 1.
<RLMFW_S_OL_CD>-OBJKEY_EXT = 1.
ENDLOOP.

LOOP AT IT_RLMFW_S_OL_CD INTO WA_RLMFW_S_OL_CD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RLMFW_S_OL_CD-TARGET, sy-vline,
WA_RLMFW_S_OL_CD-CHGIND, sy-vline,
WA_RLMFW_S_OL_CD-CHKSTA, sy-vline,
WA_RLMFW_S_OL_CD-INCPLE, sy-vline,
WA_RLMFW_S_OL_CD-PROBLM, sy-vline,
WA_RLMFW_S_OL_CD-RELSTA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RLMFW_S_OL_CD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RLMFW_S_OL_CD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RLMFW_S_OL_CD INTO WA_RLMFW_S_OL_CD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RONUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RLMFW_S_OL_CD-RONUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RLMFW_S_OL_CD-RONUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RLMFW_S_OL_CD-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RLMFW_S_OL_CD-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OBJTYP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RLMFW_S_OL_CD-OBJTYP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RLMFW_S_OL_CD-OBJTYP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RLMFW_S_OL_CD_STR,
MANDT TYPE STRING,
RONUM TYPE STRING,
LOGSYS TYPE STRING,
OBJTYP TYPE STRING,
OBJKEY_EXT TYPE STRING,
TARGET TYPE STRING,
CHGIND TYPE STRING,
CHKSTA TYPE STRING,
INCPLE TYPE STRING,
PROBLM TYPE STRING,
RELSTA TYPE STRING,
RELDAT TYPE STRING,
RELTIM TYPE STRING,
REMARK TYPE STRING,
TARDAT TYPE STRING,
RESPTP TYPE STRING,
RESPID TYPE STRING,
DELIND TYPE STRING,
CONOK TYPE STRING,
CANCEL TYPE STRING,END OF T_EKKO_STR. DATA: WA_RLMFW_S_OL_CD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RLMFW_S_OL_CD_STR-MANDT sy-vline
WA_RLMFW_S_OL_CD_STR-RONUM sy-vline
WA_RLMFW_S_OL_CD_STR-LOGSYS sy-vline
WA_RLMFW_S_OL_CD_STR-OBJTYP sy-vline
WA_RLMFW_S_OL_CD_STR-OBJKEY_EXT sy-vline
WA_RLMFW_S_OL_CD_STR-TARGET sy-vline
WA_RLMFW_S_OL_CD_STR-CHGIND sy-vline
WA_RLMFW_S_OL_CD_STR-CHKSTA sy-vline
WA_RLMFW_S_OL_CD_STR-INCPLE sy-vline
WA_RLMFW_S_OL_CD_STR-PROBLM sy-vline
WA_RLMFW_S_OL_CD_STR-RELSTA sy-vline
WA_RLMFW_S_OL_CD_STR-RELDAT sy-vline
WA_RLMFW_S_OL_CD_STR-RELTIM sy-vline
WA_RLMFW_S_OL_CD_STR-REMARK sy-vline
WA_RLMFW_S_OL_CD_STR-TARDAT sy-vline
WA_RLMFW_S_OL_CD_STR-RESPTP sy-vline
WA_RLMFW_S_OL_CD_STR-RESPID sy-vline
WA_RLMFW_S_OL_CD_STR-DELIND sy-vline
WA_RLMFW_S_OL_CD_STR-CONOK sy-vline
WA_RLMFW_S_OL_CD_STR-CANCEL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.