ABAP Select data from SAP table RK70P_I into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RK70P_I table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RK70P_I. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RK70P_I table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RK70P_I TYPE STANDARD TABLE OF RK70P_I,
      WA_RK70P_I TYPE RK70P_I,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RK70P_I> TYPE RK70P_I.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RK70P_I.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RK70P_I
  INTO TABLE IT_RK70P_I.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RK70P_I
*  INTO TABLE @DATA(IT_RK70P_I2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RK70P_I INDEX 1 INTO DATA(WA_RK70P_I2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RK70P_I ASSIGNING <RK70P_I>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RK70P_I>-PMARK = 1.
<RK70P_I>-POSNR = 1.
<RK70P_I>-TYPPS = 1.
<RK70P_I>-KSTAR = 1.
<RK70P_I>-HRKFT = 1.
ENDLOOP.

LOOP AT IT_RK70P_I INTO WA_RK70P_I.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RK70P_I-ELEMT, sy-vline,
WA_RK70P_I-MENGE, sy-vline,
WA_RK70P_I-PMEHT, sy-vline,
WA_RK70P_I-MEEHT, sy-vline,
WA_RK70P_I-LTEXT, sy-vline,
WA_RK70P_I-HERK1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RK70P_I you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RK70P_I TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RK70P_I INTO WA_RK70P_I. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KSTAR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RK70P_I-KSTAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70P_I-KSTAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PMEHT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RK70P_I-PMEHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70P_I-PMEHT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEEHT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RK70P_I-MEEHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70P_I-MEEHT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_RK70P_I-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70P_I-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field UVORN CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_RK70P_I-UVORN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70P_I-UVORN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field SPOSN CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_RK70P_I-SPOSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70P_I-SPOSN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RK70P_I_STR,
PMARK TYPE STRING,
POSNR TYPE STRING,
TYPPS TYPE STRING,
KSTAR TYPE STRING,
HRKFT TYPE STRING,
ELEMT TYPE STRING,
MENGE TYPE STRING,
PMEHT TYPE STRING,
MEEHT TYPE STRING,
LTEXT TYPE STRING,
HERK1 TYPE STRING,
HERK2 TYPE STRING,
HERK3 TYPE STRING,
PSKNZ TYPE STRING,
LPREIS TYPE STRING,
LWERTB TYPE STRING,
LPEINH TYPE STRING,
LPREIFX TYPE STRING,
LWERTFX TYPE STRING,
ARBPL TYPE STRING,
ARBPLWERK TYPE STRING,
VORNR TYPE STRING,
UVORN TYPE STRING,
SPOSN TYPE STRING,END OF T_EKKO_STR. DATA: WA_RK70P_I_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RK70P_I_STR-PMARK sy-vline
WA_RK70P_I_STR-POSNR sy-vline
WA_RK70P_I_STR-TYPPS sy-vline
WA_RK70P_I_STR-KSTAR sy-vline
WA_RK70P_I_STR-HRKFT sy-vline
WA_RK70P_I_STR-ELEMT sy-vline
WA_RK70P_I_STR-MENGE sy-vline
WA_RK70P_I_STR-PMEHT sy-vline
WA_RK70P_I_STR-MEEHT sy-vline
WA_RK70P_I_STR-LTEXT sy-vline
WA_RK70P_I_STR-HERK1 sy-vline
WA_RK70P_I_STR-HERK2 sy-vline
WA_RK70P_I_STR-HERK3 sy-vline
WA_RK70P_I_STR-PSKNZ sy-vline
WA_RK70P_I_STR-LPREIS sy-vline
WA_RK70P_I_STR-LWERTB sy-vline
WA_RK70P_I_STR-LPEINH sy-vline
WA_RK70P_I_STR-LPREIFX sy-vline
WA_RK70P_I_STR-LWERTFX sy-vline
WA_RK70P_I_STR-ARBPL sy-vline
WA_RK70P_I_STR-ARBPLWERK sy-vline
WA_RK70P_I_STR-VORNR sy-vline
WA_RK70P_I_STR-UVORN sy-vline
WA_RK70P_I_STR-SPOSN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.