ABAP Select data from SAP table RK70P3 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RK70P3 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RK70P3. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RK70P3 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RK70P3 TYPE STANDARD TABLE OF RK70P3,
      WA_RK70P3 TYPE RK70P3,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RK70P3> TYPE RK70P3.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RK70P3.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RK70P3
  INTO TABLE IT_RK70P3.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RK70P3
*  INTO TABLE @DATA(IT_RK70P32).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RK70P3 INDEX 1 INTO DATA(WA_RK70P32).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RK70P3 ASSIGNING <RK70P3>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RK70P3>-KSTAR = 1.
<RK70P3>-HRKFT = 1.
<RK70P3>-ELEMT = 1.
<RK70P3>-KOKRS = 1.
<RK70P3>-PSDAT = 1.
ENDLOOP.

LOOP AT IT_RK70P3 INTO WA_RK70P3.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RK70P3-POSNR, sy-vline,
WA_RK70P3-TYPPS, sy-vline,
WA_RK70P3-LTEXT, sy-vline,
WA_RK70P3-ELEHK, sy-vline,
WA_RK70P3-KTOPL, sy-vline,
WA_RK70P3-ELEHKNS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RK70P3 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RK70P3 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RK70P3 INTO WA_RK70P3. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KSTAR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RK70P3-KSTAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70P3-KSTAR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RK70P3_STR,
KSTAR TYPE STRING,
HRKFT TYPE STRING,
ELEMT TYPE STRING,
KOKRS TYPE STRING,
PSDAT TYPE STRING,
POSNR TYPE STRING,
TYPPS TYPE STRING,
LTEXT TYPE STRING,
ELEHK TYPE STRING,
KTOPL TYPE STRING,
ELEHKNS TYPE STRING,
FLAG_CHECK_COST_COMPONENT TYPE STRING,END OF T_EKKO_STR. DATA: WA_RK70P3_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RK70P3_STR-KSTAR sy-vline
WA_RK70P3_STR-HRKFT sy-vline
WA_RK70P3_STR-ELEMT sy-vline
WA_RK70P3_STR-KOKRS sy-vline
WA_RK70P3_STR-PSDAT sy-vline
WA_RK70P3_STR-POSNR sy-vline
WA_RK70P3_STR-TYPPS sy-vline
WA_RK70P3_STR-LTEXT sy-vline
WA_RK70P3_STR-ELEHK sy-vline
WA_RK70P3_STR-KTOPL sy-vline
WA_RK70P3_STR-ELEHKNS sy-vline
WA_RK70P3_STR-FLAG_CHECK_COST_COMPONENT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.