ABAP Select data from SAP table RK70P into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RK70P table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RK70P. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RK70P table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RK70P TYPE STANDARD TABLE OF RK70P,
      WA_RK70P TYPE RK70P,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RK70P> TYPE RK70P.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RK70P.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RK70P
  INTO TABLE IT_RK70P.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RK70P
*  INTO TABLE @DATA(IT_RK70P2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RK70P INDEX 1 INTO DATA(WA_RK70P2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RK70P ASSIGNING <RK70P>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RK70P>-SPRAS = 1.
<RK70P>-LOSNEU = 1.
<RK70P>-MEEHT = 1.
<RK70P>-ALL_STFN = 1.
<RK70P>-N_STFN = 1.
ENDLOOP.

LOOP AT IT_RK70P INTO WA_RK70P.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RK70P-ANZ_STFN, sy-vline,
WA_RK70P-FLG_TYP_B, sy-vline,
WA_RK70P-FLG_TYP_E, sy-vline,
WA_RK70P-FLG_TYP_L, sy-vline,
WA_RK70P-FLG_TYP_F, sy-vline,
WA_RK70P-FLG_TYP_M, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RK70P you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RK70P TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RK70P INTO WA_RK70P. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_RK70P-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70P-SPRAS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEEHT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RK70P-MEEHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70P-MEEHT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RK70P-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70P-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RK70P-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70P-VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RK70P-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RK70P-MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RK70P_STR,
SPRAS TYPE STRING,
LOSNEU TYPE STRING,
MEEHT TYPE STRING,
ALL_STFN TYPE STRING,
N_STFN TYPE STRING,
ANZ_STFN TYPE STRING,
FLG_TYP_B TYPE STRING,
FLG_TYP_E TYPE STRING,
FLG_TYP_L TYPE STRING,
FLG_TYP_F TYPE STRING,
FLG_TYP_M TYPE STRING,
FLG_TYP_N TYPE STRING,
FLG_TYP_P TYPE STRING,
FLG_TYP_Y TYPE STRING,
SICHT TYPE STRING,
KOSMNG TYPE STRING,
MEINS TYPE STRING,
XFLAG_MAT TYPE STRING,
VBELN TYPE STRING,
POSNR TYPE STRING,
RADIO_MAT TYPE STRING,
RADIO_VBEL TYPE STRING,
MATNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_RK70P_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RK70P_STR-SPRAS sy-vline
WA_RK70P_STR-LOSNEU sy-vline
WA_RK70P_STR-MEEHT sy-vline
WA_RK70P_STR-ALL_STFN sy-vline
WA_RK70P_STR-N_STFN sy-vline
WA_RK70P_STR-ANZ_STFN sy-vline
WA_RK70P_STR-FLG_TYP_B sy-vline
WA_RK70P_STR-FLG_TYP_E sy-vline
WA_RK70P_STR-FLG_TYP_L sy-vline
WA_RK70P_STR-FLG_TYP_F sy-vline
WA_RK70P_STR-FLG_TYP_M sy-vline
WA_RK70P_STR-FLG_TYP_N sy-vline
WA_RK70P_STR-FLG_TYP_P sy-vline
WA_RK70P_STR-FLG_TYP_Y sy-vline
WA_RK70P_STR-SICHT sy-vline
WA_RK70P_STR-KOSMNG sy-vline
WA_RK70P_STR-MEINS sy-vline
WA_RK70P_STR-XFLAG_MAT sy-vline
WA_RK70P_STR-VBELN sy-vline
WA_RK70P_STR-POSNR sy-vline
WA_RK70P_STR-RADIO_MAT sy-vline
WA_RK70P_STR-RADIO_VBEL sy-vline
WA_RK70P_STR-MATNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.