ABAP Select data from SAP table RJJW1P2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RJJW1P2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RJJW1P2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RJJW1P2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RJJW1P2 TYPE STANDARD TABLE OF RJJW1P2,
      WA_RJJW1P2 TYPE RJJW1P2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RJJW1P2> TYPE RJJW1P2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RJJW1P2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RJJW1P2
  INTO TABLE IT_RJJW1P2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RJJW1P2
*  INTO TABLE @DATA(IT_RJJW1P22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RJJW1P2 INDEX 1 INTO DATA(WA_RJJW1P22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RJJW1P2 ASSIGNING <RJJW1P2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RJJW1P2>-SELKZ = 1.
<RJJW1P2>-GPNR = 1.
<RJJW1P2>-NAME1_GPNR = 1.
<RJJW1P2>-ISP_VNR = 1.
<RJJW1P2>-ISP_BEDNR = 1.
ENDLOOP.

LOOP AT IT_RJJW1P2 INTO WA_RJJW1P2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RJJW1P2-KURZTEXT, sy-vline,
WA_RJJW1P2-TELFD, sy-vline,
WA_RJJW1P2-ADRNR_GP, sy-vline,
WA_RJJW1P2-LAND1_GP, sy-vline,
ENDLOOP. *Add any further fields from structure WA_RJJW1P2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RJJW1P2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RJJW1P2 INTO WA_RJJW1P2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit VERMK, internal->external for field GPNR CALL FUNCTION 'CONVERSION_EXIT_VERMK_OUTPUT' EXPORTING input = WA_RJJW1P2-GPNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJW1P2-GPNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ISP_VNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJW1P2-ISP_VNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJW1P2-ISP_VNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADRNR_GP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJW1P2-ADRNR_GP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJW1P2-ADRNR_GP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RJJW1P2_STR,
SELKZ TYPE STRING,
GPNR TYPE STRING,
NAME1_GPNR TYPE STRING,
ISP_VNR TYPE STRING,
ISP_BEDNR TYPE STRING,
KURZTEXT TYPE STRING,
TELFD TYPE STRING,
ADRNR_GP TYPE STRING,
LAND1_GP TYPE STRING,END OF T_EKKO_STR. DATA: WA_RJJW1P2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RJJW1P2_STR-SELKZ sy-vline
WA_RJJW1P2_STR-GPNR sy-vline
WA_RJJW1P2_STR-NAME1_GPNR sy-vline
WA_RJJW1P2_STR-ISP_VNR sy-vline
WA_RJJW1P2_STR-ISP_BEDNR sy-vline
WA_RJJW1P2_STR-KURZTEXT sy-vline
WA_RJJW1P2_STR-TELFD sy-vline
WA_RJJW1P2_STR-ADRNR_GP sy-vline
WA_RJJW1P2_STR-LAND1_GP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.