ABAP Select data from SAP table RJJP0141T1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RJJP0141T1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RJJP0141T1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RJJP0141T1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RJJP0141T1 TYPE STANDARD TABLE OF RJJP0141T1,
      WA_RJJP0141T1 TYPE RJJP0141T1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RJJP0141T1> TYPE RJJP0141T1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RJJP0141T1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RJJP0141T1
  INTO TABLE IT_RJJP0141T1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RJJP0141T1
*  INTO TABLE @DATA(IT_RJJP0141T12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RJJP0141T1 INDEX 1 INTO DATA(WA_RJJP0141T12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RJJP0141T1 ASSIGNING <RJJP0141T1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RJJP0141T1>-MANDT = 1.
<RJJP0141T1>-PACKAGE_ID = 1.
<RJJP0141T1>-PK_ELEMENT_ID = 1.
<RJJP0141T1>-ADMV_ID = 1.
<RJJP0141T1>-SEQUENCE_ID = 1.
ENDLOOP.

LOOP AT IT_RJJP0141T1 INTO WA_RJJP0141T1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RJJP0141T1-PSTYV, sy-vline,
WA_RJJP0141T1-BOOKING_UNIT, sy-vline,
WA_RJJP0141T1-CONT_COMP_LEV1, sy-vline,
WA_RJJP0141T1-BUS_CONT_COMP, sy-vline,
WA_RJJP0141T1-TECH_COMP_LEV1, sy-vline,
WA_RJJP0141T1-TECH_CONT_COMP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RJJP0141T1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RJJP0141T1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RJJP0141T1 INTO WA_RJJP0141T1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PACKAGE_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJP0141T1-PACKAGE_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-PACKAGE_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SEQUENCE_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJP0141T1-SEQUENCE_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-SEQUENCE_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BOOKING_UNIT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJP0141T1-BOOKING_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-BOOKING_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CONT_COMP_LEV1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJP0141T1-CONT_COMP_LEV1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-CONT_COMP_LEV1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BUS_CONT_COMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJP0141T1-BUS_CONT_COMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-BUS_CONT_COMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TECH_COMP_LEV1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJP0141T1-TECH_COMP_LEV1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-TECH_COMP_LEV1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TECH_CONT_COMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJP0141T1-TECH_CONT_COMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-TECH_CONT_COMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SPEC_CONT_COMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJP0141T1-SPEC_CONT_COMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-SPEC_CONT_COMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AD_DESIGN_TYPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJP0141T1-AD_DESIGN_TYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-AD_DESIGN_TYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AD_FIXED_FORMAT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJP0141T1-AD_FIXED_FORMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-AD_FIXED_FORMAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AD_COLOR_SCHEME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJP0141T1-AD_COLOR_SCHEME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-AD_COLOR_SCHEME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AD_SHAPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJP0141T1-AD_SHAPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-AD_SHAPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field POS_INSTRUCTION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJP0141T1-POS_INSTRUCTION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-POS_INSTRUCTION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DATE_SPEC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJP0141T1-DATE_SPEC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-DATE_SPEC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TERMT, internal->external for field DATE_CATEGORY CALL FUNCTION 'CONVERSION_EXIT_TERMT_OUTPUT' EXPORTING input = WA_RJJP0141T1-DATE_CATEGORY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-DATE_CATEGORY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PUBL_FREQUENCY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJP0141T1-PUBL_FREQUENCY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-PUBL_FREQUENCY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field HEIGHT_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RJJP0141T1-HEIGHT_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-HEIGHT_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WIDTH_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RJJP0141T1-WIDTH_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-WIDTH_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field AD_SIZE_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RJJP0141T1-AD_SIZE_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-AD_SIZE_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BASIC_BOOK_UNIT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJP0141T1-BASIC_BOOK_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJP0141T1-BASIC_BOOK_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RJJP0141T1_STR,
MANDT TYPE STRING,
PACKAGE_ID TYPE STRING,
PK_ELEMENT_ID TYPE STRING,
ADMV_ID TYPE STRING,
SEQUENCE_ID TYPE STRING,
PSTYV TYPE STRING,
BOOKING_UNIT TYPE STRING,
CONT_COMP_LEV1 TYPE STRING,
BUS_CONT_COMP TYPE STRING,
TECH_COMP_LEV1 TYPE STRING,
TECH_CONT_COMP TYPE STRING,
SPEC_CONT_COMP TYPE STRING,
AD_DESIGN_TYPE TYPE STRING,
AD_FIXED_FORMAT TYPE STRING,
AD_COLOR_SCHEME TYPE STRING,
AD_SHAPE TYPE STRING,
POS_INSTRUCTION TYPE STRING,
POS_AD_TYPE TYPE STRING,
AD_SPEC_HANDLING TYPE STRING,
DATE_SPEC TYPE STRING,
DATE_CATEGORY TYPE STRING,
PUBL_FREQUENCY TYPE STRING,
WEB_PUBLICATION TYPE STRING,
MONDAY TYPE STRING,
TUESDAY TYPE STRING,
WEDNESDAY TYPE STRING,
THURSDAY TYPE STRING,
FRIDAY TYPE STRING,
SATURDAY TYPE STRING,
SUNDAY TYPE STRING,
PLAN_HEIGHT TYPE STRING,
HEIGHT_UOM TYPE STRING,
PLAN_WIDTH TYPE STRING,
WIDTH_UOM TYPE STRING,
NUM_OF_PUBL TYPE STRING,
PLAN_HEIGHT_MIN TYPE STRING,
PLAN_HEIGHT_MAX TYPE STRING,
PLAN_WIDTH_MIN TYPE STRING,
PLAN_WIDTH_MAX TYPE STRING,
AD_SIZE_MIN TYPE STRING,
AD_SIZE_MAX TYPE STRING,
NUM_OF_PUBL_MIN TYPE STRING,
NUM_OF_PUBL_MAX TYPE STRING,
NUM_OF_SL_MIN TYPE STRING,
NUM_OF_SL_MAX TYPE STRING,
SERV_DATE_MIN TYPE STRING,
SERV_DATE_MAX TYPE STRING,
SERV_DATE_TO_MIN TYPE STRING,
SERV_DATE_TO_MAX TYPE STRING,
NUM_OF_SL TYPE STRING,
SERV_DATE TYPE STRING,
SERV_DATE_TO TYPE STRING,
AD_SIZE TYPE STRING,
AD_SIZE_UOM TYPE STRING,
BASIC_BOOK_UNIT TYPE STRING,
DBCODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_RJJP0141T1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RJJP0141T1_STR-MANDT sy-vline
WA_RJJP0141T1_STR-PACKAGE_ID sy-vline
WA_RJJP0141T1_STR-PK_ELEMENT_ID sy-vline
WA_RJJP0141T1_STR-ADMV_ID sy-vline
WA_RJJP0141T1_STR-SEQUENCE_ID sy-vline
WA_RJJP0141T1_STR-PSTYV sy-vline
WA_RJJP0141T1_STR-BOOKING_UNIT sy-vline
WA_RJJP0141T1_STR-CONT_COMP_LEV1 sy-vline
WA_RJJP0141T1_STR-BUS_CONT_COMP sy-vline
WA_RJJP0141T1_STR-TECH_COMP_LEV1 sy-vline
WA_RJJP0141T1_STR-TECH_CONT_COMP sy-vline
WA_RJJP0141T1_STR-SPEC_CONT_COMP sy-vline
WA_RJJP0141T1_STR-AD_DESIGN_TYPE sy-vline
WA_RJJP0141T1_STR-AD_FIXED_FORMAT sy-vline
WA_RJJP0141T1_STR-AD_COLOR_SCHEME sy-vline
WA_RJJP0141T1_STR-AD_SHAPE sy-vline
WA_RJJP0141T1_STR-POS_INSTRUCTION sy-vline
WA_RJJP0141T1_STR-POS_AD_TYPE sy-vline
WA_RJJP0141T1_STR-AD_SPEC_HANDLING sy-vline
WA_RJJP0141T1_STR-DATE_SPEC sy-vline
WA_RJJP0141T1_STR-DATE_CATEGORY sy-vline
WA_RJJP0141T1_STR-PUBL_FREQUENCY sy-vline
WA_RJJP0141T1_STR-WEB_PUBLICATION sy-vline
WA_RJJP0141T1_STR-MONDAY sy-vline
WA_RJJP0141T1_STR-TUESDAY sy-vline
WA_RJJP0141T1_STR-WEDNESDAY sy-vline
WA_RJJP0141T1_STR-THURSDAY sy-vline
WA_RJJP0141T1_STR-FRIDAY sy-vline
WA_RJJP0141T1_STR-SATURDAY sy-vline
WA_RJJP0141T1_STR-SUNDAY sy-vline
WA_RJJP0141T1_STR-PLAN_HEIGHT sy-vline
WA_RJJP0141T1_STR-HEIGHT_UOM sy-vline
WA_RJJP0141T1_STR-PLAN_WIDTH sy-vline
WA_RJJP0141T1_STR-WIDTH_UOM sy-vline
WA_RJJP0141T1_STR-NUM_OF_PUBL sy-vline
WA_RJJP0141T1_STR-PLAN_HEIGHT_MIN sy-vline
WA_RJJP0141T1_STR-PLAN_HEIGHT_MAX sy-vline
WA_RJJP0141T1_STR-PLAN_WIDTH_MIN sy-vline
WA_RJJP0141T1_STR-PLAN_WIDTH_MAX sy-vline
WA_RJJP0141T1_STR-AD_SIZE_MIN sy-vline
WA_RJJP0141T1_STR-AD_SIZE_MAX sy-vline
WA_RJJP0141T1_STR-NUM_OF_PUBL_MIN sy-vline
WA_RJJP0141T1_STR-NUM_OF_PUBL_MAX sy-vline
WA_RJJP0141T1_STR-NUM_OF_SL_MIN sy-vline
WA_RJJP0141T1_STR-NUM_OF_SL_MAX sy-vline
WA_RJJP0141T1_STR-SERV_DATE_MIN sy-vline
WA_RJJP0141T1_STR-SERV_DATE_MAX sy-vline
WA_RJJP0141T1_STR-SERV_DATE_TO_MIN sy-vline
WA_RJJP0141T1_STR-SERV_DATE_TO_MAX sy-vline
WA_RJJP0141T1_STR-NUM_OF_SL sy-vline
WA_RJJP0141T1_STR-SERV_DATE sy-vline
WA_RJJP0141T1_STR-SERV_DATE_TO sy-vline
WA_RJJP0141T1_STR-AD_SIZE sy-vline
WA_RJJP0141T1_STR-AD_SIZE_UOM sy-vline
WA_RJJP0141T1_STR-BASIC_BOOK_UNIT sy-vline
WA_RJJP0141T1_STR-DBCODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.