ABAP Select data from SAP table RJJ0201 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP RJJ0201 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RJJ0201. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the RJJ0201 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_RJJ0201 TYPE STANDARD TABLE OF RJJ0201, WA_RJJ0201 TYPE RJJ0201, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <RJJ0201> TYPE RJJ0201. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_RJJ0201. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM RJJ0201 INTO TABLE IT_RJJ0201. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM RJJ0201 * INTO TABLE @DATA(IT_RJJ02012). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_RJJ0201 INDEX 1 INTO DATA(WA_RJJ02012). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_RJJ0201 ASSIGNING <RJJ0201>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<RJJ0201>-BELEINH = 1.
<RJJ0201>-ERSCHDAT = 1.
<RJJ0201>-BELEINHUEB = 1.
<RJJ0201>-CAPACITY = 1.
<RJJ0201>-PLATZ_FREI = 1.
ENDLOOP. LOOP AT IT_RJJ0201 INTO WA_RJJ0201. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_RJJ0201-PLATZ_RESV, sy-vline,
WA_RJJ0201-PLATZ_BELE, sy-vline,
WA_RJJ0201-TEILBELEG, sy-vline,
WA_RJJ0201-TEIL_RESV, sy-vline,
WA_RJJ0201-TEIL_UNPLZ, sy-vline,
WA_RJJ0201-TRES_UNPLZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RJJ0201 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RJJ0201 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RJJ0201 INTO WA_RJJ0201. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field BELEINH CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJ0201-BELEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJ0201-BELEINH.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field BELEINHUEB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RJJ0201-BELEINHUEB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJ0201-BELEINHUEB.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNITTEILBL CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RJJ0201-UNITTEILBL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RJJ0201-UNITTEILBL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RJJ0201_STR,
BELEINH TYPE STRING,
ERSCHDAT TYPE STRING,
BELEINHUEB TYPE STRING,
CAPACITY TYPE STRING,
PLATZ_FREI TYPE STRING,
PLATZ_RESV TYPE STRING,
PLATZ_BELE TYPE STRING,
TEILBELEG TYPE STRING,
TEIL_RESV TYPE STRING,
TEIL_UNPLZ TYPE STRING,
TRES_UNPLZ TYPE STRING,
UNITTEILBL TYPE STRING,
FIRST_MEMB TYPE STRING,
NEXT_MEMB TYPE STRING,
XAUFLOE TYPE STRING,
XMINCPCITY TYPE STRING,
POTENTIAL TYPE STRING,
IS_INITIAL TYPE STRING,END OF T_EKKO_STR. DATA: WA_RJJ0201_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RJJ0201_STR-BELEINH sy-vline
WA_RJJ0201_STR-ERSCHDAT sy-vline
WA_RJJ0201_STR-BELEINHUEB sy-vline
WA_RJJ0201_STR-CAPACITY sy-vline
WA_RJJ0201_STR-PLATZ_FREI sy-vline
WA_RJJ0201_STR-PLATZ_RESV sy-vline
WA_RJJ0201_STR-PLATZ_BELE sy-vline
WA_RJJ0201_STR-TEILBELEG sy-vline
WA_RJJ0201_STR-TEIL_RESV sy-vline
WA_RJJ0201_STR-TEIL_UNPLZ sy-vline
WA_RJJ0201_STR-TRES_UNPLZ sy-vline
WA_RJJ0201_STR-UNITTEILBL sy-vline
WA_RJJ0201_STR-FIRST_MEMB sy-vline
WA_RJJ0201_STR-NEXT_MEMB sy-vline
WA_RJJ0201_STR-XAUFLOE sy-vline
WA_RJJ0201_STR-XMINCPCITY sy-vline
WA_RJJ0201_STR-POTENTIAL sy-vline
WA_RJJ0201_STR-IS_INITIAL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.