ABAP Select data from SAP table RIFLTCONS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RIFLTCONS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RIFLTCONS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RIFLTCONS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RIFLTCONS TYPE STANDARD TABLE OF RIFLTCONS,
      WA_RIFLTCONS TYPE RIFLTCONS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RIFLTCONS> TYPE RIFLTCONS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RIFLTCONS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RIFLTCONS
  INTO TABLE IT_RIFLTCONS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RIFLTCONS
*  INTO TABLE @DATA(IT_RIFLTCONS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RIFLTCONS INDEX 1 INTO DATA(WA_RIFLTCONS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RIFLTCONS ASSIGNING <RIFLTCONS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RIFLTCONS>-POINT = 1.
<RIFLTCONS>-PSORT = 1.
<RIFLTCONS>-PTTXT = 1.
<RIFLTCONS>-CNSPT_REL = 1.
<RIFLTCONS>-PRI_FUEL = 1.
ENDLOOP.

LOOP AT IT_RIFLTCONS INTO WA_RIFLTCONS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RIFLTCONS-SEC_FUEL, sy-vline,
WA_RIFLTCONS-CONSP_OIL, sy-vline,
WA_RIFLTCONS-RECDF, sy-vline,
WA_RIFLTCONS-MSEHI, sy-vline,
WA_RIFLTCONS-MSEH6, sy-vline,
WA_RIFLTCONS-FLUID_TYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RIFLTCONS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RIFLTCONS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RIFLTCONS INTO WA_RIFLTCONS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field POINT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RIFLTCONS-POINT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RIFLTCONS-POINT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MSEHI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RIFLTCONS-MSEHI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RIFLTCONS-MSEHI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field FLUID_MAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RIFLTCONS-FLUID_MAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RIFLTCONS-FLUID_MAT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RIFLTCONS_STR,
POINT TYPE STRING,
PSORT TYPE STRING,
PTTXT TYPE STRING,
CNSPT_REL TYPE STRING,
PRI_FUEL TYPE STRING,
SEC_FUEL TYPE STRING,
CONSP_OIL TYPE STRING,
RECDF TYPE STRING,
MSEHI TYPE STRING,
MSEH6 TYPE STRING,
FLUID_TYPE TYPE STRING,
FLUID_MAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_RIFLTCONS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RIFLTCONS_STR-POINT sy-vline
WA_RIFLTCONS_STR-PSORT sy-vline
WA_RIFLTCONS_STR-PTTXT sy-vline
WA_RIFLTCONS_STR-CNSPT_REL sy-vline
WA_RIFLTCONS_STR-PRI_FUEL sy-vline
WA_RIFLTCONS_STR-SEC_FUEL sy-vline
WA_RIFLTCONS_STR-CONSP_OIL sy-vline
WA_RIFLTCONS_STR-RECDF sy-vline
WA_RIFLTCONS_STR-MSEHI sy-vline
WA_RIFLTCONS_STR-MSEH6 sy-vline
WA_RIFLTCONS_STR-FLUID_TYPE sy-vline
WA_RIFLTCONS_STR-FLUID_MAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.