ABAP Select data from SAP table RFVIREPMV_01 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RFVIREPMV_01 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RFVIREPMV_01. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RFVIREPMV_01 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RFVIREPMV_01 TYPE STANDARD TABLE OF RFVIREPMV_01,
      WA_RFVIREPMV_01 TYPE RFVIREPMV_01,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RFVIREPMV_01> TYPE RFVIREPMV_01.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RFVIREPMV_01.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RFVIREPMV_01
  INTO TABLE IT_RFVIREPMV_01.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RFVIREPMV_01
*  INTO TABLE @DATA(IT_RFVIREPMV_012).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RFVIREPMV_01 INDEX 1 INTO DATA(WA_RFVIREPMV_012).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RFVIREPMV_01 ASSIGNING <RFVIREPMV_01>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RFVIREPMV_01>-SMVART = 1.
<RFVIREPMV_01>-SMVARTTXT = 1.
<RFVIREPMV_01>-SMVANART = 1.
<RFVIREPMV_01>-SMVANARTTXT = 1.
<RFVIREPMV_01>-SKUEART = 1.
ENDLOOP.

LOOP AT IT_RFVIREPMV_01 INTO WA_RFVIREPMV_01.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RFVIREPMV_01-SKUEARTTXT, sy-vline,
WA_RFVIREPMV_01-SKUEKEY, sy-vline,
WA_RFVIREPMV_01-DKUEFR, sy-vline,
WA_RFVIREPMV_01-SKUEFR, sy-vline,
WA_RFVIREPMV_01-DEINKUE, sy-vline,
WA_RFVIREPMV_01-JVERL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RFVIREPMV_01 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RFVIREPMV_01 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RFVIREPMV_01 INTO WA_RFVIREPMV_01. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RLGESCH CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFVIREPMV_01-RLGESCH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFVIREPMV_01-RLGESCH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RFVIREPMV_01_STR,
SMVART TYPE STRING,
SMVARTTXT TYPE STRING,
SMVANART TYPE STRING,
SMVANARTTXT TYPE STRING,
SKUEART TYPE STRING,
SKUEARTTXT TYPE STRING,
SKUEKEY TYPE STRING,
DKUEFR TYPE STRING,
SKUEFR TYPE STRING,
DEINKUE TYPE STRING,
JVERL TYPE STRING,
ANKUEN TYPE STRING,
VERLG TYPE STRING,
JKAUFOPT TYPE STRING,
DKAUFOPT TYPE STRING,
DEINZG TYPE STRING,
DAUSZG TYPE STRING,
GERSTD TYPE STRING,
IND_SECTOR TYPE STRING,
PARTFROM TYPE STRING,
PARTWHY TYPE STRING,
SSTOCKW TYPE STRING,
SSTOCKWTXT TYPE STRING,
RLGESCH TYPE STRING,
RLGESCHTXT TYPE STRING,
SGEBT TYPE STRING,
SGEBTTXT TYPE STRING,
USRSTATUS TYPE STRING,END OF T_EKKO_STR. DATA: WA_RFVIREPMV_01_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RFVIREPMV_01_STR-SMVART sy-vline
WA_RFVIREPMV_01_STR-SMVARTTXT sy-vline
WA_RFVIREPMV_01_STR-SMVANART sy-vline
WA_RFVIREPMV_01_STR-SMVANARTTXT sy-vline
WA_RFVIREPMV_01_STR-SKUEART sy-vline
WA_RFVIREPMV_01_STR-SKUEARTTXT sy-vline
WA_RFVIREPMV_01_STR-SKUEKEY sy-vline
WA_RFVIREPMV_01_STR-DKUEFR sy-vline
WA_RFVIREPMV_01_STR-SKUEFR sy-vline
WA_RFVIREPMV_01_STR-DEINKUE sy-vline
WA_RFVIREPMV_01_STR-JVERL sy-vline
WA_RFVIREPMV_01_STR-ANKUEN sy-vline
WA_RFVIREPMV_01_STR-VERLG sy-vline
WA_RFVIREPMV_01_STR-JKAUFOPT sy-vline
WA_RFVIREPMV_01_STR-DKAUFOPT sy-vline
WA_RFVIREPMV_01_STR-DEINZG sy-vline
WA_RFVIREPMV_01_STR-DAUSZG sy-vline
WA_RFVIREPMV_01_STR-GERSTD sy-vline
WA_RFVIREPMV_01_STR-IND_SECTOR sy-vline
WA_RFVIREPMV_01_STR-PARTFROM sy-vline
WA_RFVIREPMV_01_STR-PARTWHY sy-vline
WA_RFVIREPMV_01_STR-SSTOCKW sy-vline
WA_RFVIREPMV_01_STR-SSTOCKWTXT sy-vline
WA_RFVIREPMV_01_STR-RLGESCH sy-vline
WA_RFVIREPMV_01_STR-RLGESCHTXT sy-vline
WA_RFVIREPMV_01_STR-SGEBT sy-vline
WA_RFVIREPMV_01_STR-SGEBTTXT sy-vline
WA_RFVIREPMV_01_STR-USRSTATUS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.