ABAP Select data from SAP table RFSRER_FIX into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RFSRER_FIX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RFSRER_FIX. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RFSRER_FIX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RFSRER_FIX TYPE STANDARD TABLE OF RFSRER_FIX,
      WA_RFSRER_FIX TYPE RFSRER_FIX,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RFSRER_FIX> TYPE RFSRER_FIX.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RFSRER_FIX.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RFSRER_FIX
  INTO TABLE IT_RFSRER_FIX.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RFSRER_FIX
*  INTO TABLE @DATA(IT_RFSRER_FIX2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RFSRER_FIX INDEX 1 INTO DATA(WA_RFSRER_FIX2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RFSRER_FIX ASSIGNING <RFSRER_FIX>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RFSRER_FIX>-MAXPER = 1.
<RFSRER_FIX>-PERIO = 1.
<RFSRER_FIX>-WERTB = 1.
<RFSRER_FIX>-WERTE = 1.
<RFSRER_FIX>-UMSAV = 1.
ENDLOOP.

LOOP AT IT_RFSRER_FIX INTO WA_RFSRER_FIX.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RFSRER_FIX-UMSOL, sy-vline,
WA_RFSRER_FIX-UMHAB, sy-vline,
WA_RFSRER_FIX-UMPER, sy-vline,
WA_RFSRER_FIX-KUMSL, sy-vline,
WA_RFSRER_FIX-MENGP, sy-vline,
WA_RFSRER_FIX-MENGK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RFSRER_FIX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RFSRER_FIX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RFSRER_FIX INTO WA_RFSRER_FIX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PERI7, internal->external for field PERIO CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_RFSRER_FIX-PERIO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSRER_FIX-PERIO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field WERTB CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_RFSRER_FIX-WERTB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSRER_FIX-WERTB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field WERTE CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_RFSRER_FIX-WERTE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSRER_FIX-WERTE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field UMSAV CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_RFSRER_FIX-UMSAV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSRER_FIX-UMSAV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field UMSOL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_RFSRER_FIX-UMSOL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSRER_FIX-UMSOL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field UMHAB CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_RFSRER_FIX-UMHAB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSRER_FIX-UMHAB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field UMPER CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_RFSRER_FIX-UMPER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSRER_FIX-UMPER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KUMSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_RFSRER_FIX-KUMSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSRER_FIX-KUMSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field ADB_WERTB CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_RFSRER_FIX-ADB_WERTB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSRER_FIX-ADB_WERTB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field ADB_WERTE CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_RFSRER_FIX-ADB_WERTE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSRER_FIX-ADB_WERTE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field ADB_KUMSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_RFSRER_FIX-ADB_KUMSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSRER_FIX-ADB_KUMSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field ADB_UMPER CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_RFSRER_FIX-ADB_UMPER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSRER_FIX-ADB_UMPER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RFSRER_FIX_STR,
MAXPER TYPE STRING,
PERIO TYPE STRING,
WERTB TYPE STRING,
WERTE TYPE STRING,
UMSAV TYPE STRING,
UMSOL TYPE STRING,
UMHAB TYPE STRING,
UMPER TYPE STRING,
KUMSL TYPE STRING,
MENGP TYPE STRING,
MENGK TYPE STRING,
ADB_WERTB TYPE STRING,
ADB_WERTE TYPE STRING,
ADB_KUMSL TYPE STRING,
ADB_UMPER TYPE STRING,END OF T_EKKO_STR. DATA: WA_RFSRER_FIX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RFSRER_FIX_STR-MAXPER sy-vline
WA_RFSRER_FIX_STR-PERIO sy-vline
WA_RFSRER_FIX_STR-WERTB sy-vline
WA_RFSRER_FIX_STR-WERTE sy-vline
WA_RFSRER_FIX_STR-UMSAV sy-vline
WA_RFSRER_FIX_STR-UMSOL sy-vline
WA_RFSRER_FIX_STR-UMHAB sy-vline
WA_RFSRER_FIX_STR-UMPER sy-vline
WA_RFSRER_FIX_STR-KUMSL sy-vline
WA_RFSRER_FIX_STR-MENGP sy-vline
WA_RFSRER_FIX_STR-MENGK sy-vline
WA_RFSRER_FIX_STR-ADB_WERTB sy-vline
WA_RFSRER_FIX_STR-ADB_WERTE sy-vline
WA_RFSRER_FIX_STR-ADB_KUMSL sy-vline
WA_RFSRER_FIX_STR-ADB_UMPER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.