ABAP Select data from SAP table RFSBEW_INCL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RFSBEW_INCL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RFSBEW_INCL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RFSBEW_INCL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RFSBEW_INCL TYPE STANDARD TABLE OF RFSBEW_INCL,
      WA_RFSBEW_INCL TYPE RFSBEW_INCL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RFSBEW_INCL> TYPE RFSBEW_INCL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RFSBEW_INCL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RFSBEW_INCL
  INTO TABLE IT_RFSBEW_INCL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RFSBEW_INCL
*  INTO TABLE @DATA(IT_RFSBEW_INCL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RFSBEW_INCL INDEX 1 INTO DATA(WA_RFSBEW_INCL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RFSBEW_INCL ASSIGNING <RFSBEW_INCL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RFSBEW_INCL>-SCNTR = 1.
<RFSBEW_INCL>-PPRCTR = 1.
<RFSBEW_INCL>-SFAREA = 1.
<RFSBEW_INCL>-SBUSA = 1.
<RFSBEW_INCL>-RASSC = 1.
ENDLOOP.

LOOP AT IT_RFSBEW_INCL INTO WA_RFSBEW_INCL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RFSBEW_INCL-RCNTR, sy-vline,
WA_RFSBEW_INCL-PRCTR, sy-vline,
WA_RFSBEW_INCL-RFAREA, sy-vline,
WA_RFSBEW_INCL-RBUSA, sy-vline,
WA_RFSBEW_INCL-KOKRS, sy-vline,
WA_RFSBEW_INCL-ACTIV, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RFSBEW_INCL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RFSBEW_INCL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RFSBEW_INCL INTO WA_RFSBEW_INCL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SCNTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFSBEW_INCL-SCNTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSBEW_INCL-SCNTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PPRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFSBEW_INCL-PPRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSBEW_INCL-PPRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RASSC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFSBEW_INCL-RASSC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSBEW_INCL-RASSC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RCNTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFSBEW_INCL-RCNTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSBEW_INCL-RCNTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFSBEW_INCL-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSBEW_INCL-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RFSBEW_INCL-RUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFSBEW_INCL-RUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RFSBEW_INCL_STR,
SCNTR TYPE STRING,
PPRCTR TYPE STRING,
SFAREA TYPE STRING,
SBUSA TYPE STRING,
RASSC TYPE STRING,
RCNTR TYPE STRING,
PRCTR TYPE STRING,
RFAREA TYPE STRING,
RBUSA TYPE STRING,
KOKRS TYPE STRING,
ACTIV TYPE STRING,
RMVCT TYPE STRING,
RTCUR TYPE STRING,
RUNIT TYPE STRING,END OF T_EKKO_STR. DATA: WA_RFSBEW_INCL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RFSBEW_INCL_STR-SCNTR sy-vline
WA_RFSBEW_INCL_STR-PPRCTR sy-vline
WA_RFSBEW_INCL_STR-SFAREA sy-vline
WA_RFSBEW_INCL_STR-SBUSA sy-vline
WA_RFSBEW_INCL_STR-RASSC sy-vline
WA_RFSBEW_INCL_STR-RCNTR sy-vline
WA_RFSBEW_INCL_STR-PRCTR sy-vline
WA_RFSBEW_INCL_STR-RFAREA sy-vline
WA_RFSBEW_INCL_STR-RBUSA sy-vline
WA_RFSBEW_INCL_STR-KOKRS sy-vline
WA_RFSBEW_INCL_STR-ACTIV sy-vline
WA_RFSBEW_INCL_STR-RMVCT sy-vline
WA_RFSBEW_INCL_STR-RTCUR sy-vline
WA_RFSBEW_INCL_STR-RUNIT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.