ABAP Select data from SAP table RFPDC_PTV_POSTDATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RFPDC_PTV_POSTDATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RFPDC_PTV_POSTDATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RFPDC_PTV_POSTDATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RFPDC_PTV_POSTDATA TYPE STANDARD TABLE OF RFPDC_PTV_POSTDATA,
      WA_RFPDC_PTV_POSTDATA TYPE RFPDC_PTV_POSTDATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RFPDC_PTV_POSTDATA> TYPE RFPDC_PTV_POSTDATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RFPDC_PTV_POSTDATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RFPDC_PTV_POSTDATA
  INTO TABLE IT_RFPDC_PTV_POSTDATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RFPDC_PTV_POSTDATA
*  INTO TABLE @DATA(IT_RFPDC_PTV_POSTDATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RFPDC_PTV_POSTDATA INDEX 1 INTO DATA(WA_RFPDC_PTV_POSTDATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RFPDC_PTV_POSTDATA ASSIGNING <RFPDC_PTV_POSTDATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RFPDC_PTV_POSTDATA>-FIKEY = 1.
<RFPDC_PTV_POSTDATA>-BUKRS_FROM = 1.
<RFPDC_PTV_POSTDATA>-BUKRS = 1.
<RFPDC_PTV_POSTDATA>-BLART = 1.
<RFPDC_PTV_POSTDATA>-BLDAT = 1.
ENDLOOP.

LOOP AT IT_RFPDC_PTV_POSTDATA INTO WA_RFPDC_PTV_POSTDATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RFPDC_PTV_POSTDATA-BUDAT, sy-vline,
WA_RFPDC_PTV_POSTDATA-VALUT, sy-vline,
WA_RFPDC_PTV_POSTDATA-SDATE, sy-vline,
WA_RFPDC_PTV_POSTDATA-TRREF, sy-vline,
WA_RFPDC_PTV_POSTDATA-XBLNR, sy-vline,
WA_RFPDC_PTV_POSTDATA-KUKON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RFPDC_PTV_POSTDATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RFPDC_PTV_POSTDATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RFPDC_PTV_POSTDATA INTO WA_RFPDC_PTV_POSTDATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field HKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFPDC_PTV_POSTDATA-HKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFPDC_PTV_POSTDATA-HKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFPDC_PTV_POSTDATA-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFPDC_PTV_POSTDATA-PRCTR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RFPDC_PTV_POSTDATA_STR,
FIKEY TYPE STRING,
BUKRS_FROM TYPE STRING,
BUKRS TYPE STRING,
BLART TYPE STRING,
BLDAT TYPE STRING,
BUDAT TYPE STRING,
VALUT TYPE STRING,
SDATE TYPE STRING,
TRREF TYPE STRING,
XBLNR TYPE STRING,
KUKON TYPE STRING,
HKONT TYPE STRING,
GSBER TYPE STRING,
PRCTR TYPE STRING,END OF T_EKKO_STR. DATA: WA_RFPDC_PTV_POSTDATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RFPDC_PTV_POSTDATA_STR-FIKEY sy-vline
WA_RFPDC_PTV_POSTDATA_STR-BUKRS_FROM sy-vline
WA_RFPDC_PTV_POSTDATA_STR-BUKRS sy-vline
WA_RFPDC_PTV_POSTDATA_STR-BLART sy-vline
WA_RFPDC_PTV_POSTDATA_STR-BLDAT sy-vline
WA_RFPDC_PTV_POSTDATA_STR-BUDAT sy-vline
WA_RFPDC_PTV_POSTDATA_STR-VALUT sy-vline
WA_RFPDC_PTV_POSTDATA_STR-SDATE sy-vline
WA_RFPDC_PTV_POSTDATA_STR-TRREF sy-vline
WA_RFPDC_PTV_POSTDATA_STR-XBLNR sy-vline
WA_RFPDC_PTV_POSTDATA_STR-KUKON sy-vline
WA_RFPDC_PTV_POSTDATA_STR-HKONT sy-vline
WA_RFPDC_PTV_POSTDATA_STR-GSBER sy-vline
WA_RFPDC_PTV_POSTDATA_STR-PRCTR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.