ABAP Select data from SAP table RFM_PSST_VIS_VALV_STO_S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RFM_PSST_VIS_VALV_STO_S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RFM_PSST_VIS_VALV_STO_S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RFM_PSST_VIS_VALV_STO_S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RFM_PSST_VIS_VALV_STO_S TYPE STANDARD TABLE OF RFM_PSST_VIS_VALV_STO_S,
      WA_RFM_PSST_VIS_VALV_STO_S TYPE RFM_PSST_VIS_VALV_STO_S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RFM_PSST_VIS_VALV_STO_S> TYPE RFM_PSST_VIS_VALV_STO_S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RFM_PSST_VIS_VALV_STO_S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RFM_PSST_VIS_VALV_STO_S
  INTO TABLE IT_RFM_PSST_VIS_VALV_STO_S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RFM_PSST_VIS_VALV_STO_S
*  INTO TABLE @DATA(IT_RFM_PSST_VIS_VALV_STO_S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RFM_PSST_VIS_VALV_STO_S INDEX 1 INTO DATA(WA_RFM_PSST_VIS_VALV_STO_S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RFM_PSST_VIS_VALV_STO_S ASSIGNING <RFM_PSST_VIS_VALV_STO_S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RFM_PSST_VIS_VALV_STO_S>-EBELN = 1.
<RFM_PSST_VIS_VALV_STO_S>-EBELP = 1.
<RFM_PSST_VIS_VALV_STO_S>-BSART = 1.
<RFM_PSST_VIS_VALV_STO_S>-VKORG = 1.
<RFM_PSST_VIS_VALV_STO_S>-UEPOS = 1.
ENDLOOP.

LOOP AT IT_RFM_PSST_VIS_VALV_STO_S INTO WA_RFM_PSST_VIS_VALV_STO_S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RFM_PSST_VIS_VALV_STO_S-T001W_NAME1, sy-vline,
WA_RFM_PSST_VIS_VALV_STO_S-FSH_SEASON_YEAR, sy-vline,
WA_RFM_PSST_VIS_VALV_STO_S-FSH_SEASON, sy-vline,
WA_RFM_PSST_VIS_VALV_STO_S-RFM_SEASON_DESC, sy-vline,
WA_RFM_PSST_VIS_VALV_STO_S-FSH_COLLECTION, sy-vline,
WA_RFM_PSST_VIS_VALV_STO_S-RFM_COLLECTION_DES, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RFM_PSST_VIS_VALV_STO_S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RFM_PSST_VIS_VALV_STO_S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RFM_PSST_VIS_VALV_STO_S INTO WA_RFM_PSST_VIS_VALV_STO_S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFM_PSST_VIS_VALV_STO_S-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFM_PSST_VIS_VALV_STO_S-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RFM_PSST_GROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFM_PSST_VIS_VALV_STO_S-RFM_PSST_GROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFM_PSST_VIS_VALV_STO_S-RFM_PSST_GROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RFM_PSST_VIS_VALV_STO_S-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFM_PSST_VIS_VALV_STO_S-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RFM_PSST_VIS_VALV_STO_S-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFM_PSST_VIS_VALV_STO_S-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field SATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RFM_PSST_VIS_VALV_STO_S-SATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFM_PSST_VIS_VALV_STO_S-SATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field DISP_MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RFM_PSST_VIS_VALV_STO_S-DISP_MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFM_PSST_VIS_VALV_STO_S-DISP_MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFM_PSST_VIS_VALV_STO_S-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFM_PSST_VIS_VALV_STO_S-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LMEIN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RFM_PSST_VIS_VALV_STO_S-LMEIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFM_PSST_VIS_VALV_STO_S-LMEIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AKTNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFM_PSST_VIS_VALV_STO_S-AKTNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFM_PSST_VIS_VALV_STO_S-AKTNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ABELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RFM_PSST_VIS_VALV_STO_S-ABELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFM_PSST_VIS_VALV_STO_S-ABELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ATINN, internal->external for field COLOR_ATINN CALL FUNCTION 'CONVERSION_EXIT_ATINN_OUTPUT' EXPORTING input = WA_RFM_PSST_VIS_VALV_STO_S-COLOR_ATINN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFM_PSST_VIS_VALV_STO_S-COLOR_ATINN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ATINN, internal->external for field SIZE1_ATINN CALL FUNCTION 'CONVERSION_EXIT_ATINN_OUTPUT' EXPORTING input = WA_RFM_PSST_VIS_VALV_STO_S-SIZE1_ATINN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFM_PSST_VIS_VALV_STO_S-SIZE1_ATINN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ATINN, internal->external for field SIZE2_ATINN CALL FUNCTION 'CONVERSION_EXIT_ATINN_OUTPUT' EXPORTING input = WA_RFM_PSST_VIS_VALV_STO_S-SIZE2_ATINN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFM_PSST_VIS_VALV_STO_S-SIZE2_ATINN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RFM_PSST_VIS_VALV_STO_S_STR,
EBELN TYPE STRING,
EBELP TYPE STRING,
BSART TYPE STRING,
VKORG TYPE STRING,
UEPOS TYPE STRING,
T001W_NAME1 TYPE STRING,
FSH_SEASON_YEAR TYPE STRING,
FSH_SEASON TYPE STRING,
RFM_SEASON_DESC TYPE STRING,
FSH_COLLECTION TYPE STRING,
RFM_COLLECTION_DES TYPE STRING,
FSH_THEME TYPE STRING,
RFM_THEME_DESC TYPE STRING,
RFM_PSST_RULE TYPE STRING,
RFM_PSST_GROUP TYPE STRING,
MATNR TYPE STRING,
MAKTX TYPE STRING,
MATKL TYPE STRING,
SGT_RCAT TYPE STRING,
REQQTY_BU TYPE STRING,
MEINS TYPE STRING,
LFGSA TYPE STRING,
ATTYP TYPE STRING,
SATNR TYPE STRING,
DISP_MATNR TYPE STRING,
DISP_MATNR_MAKTX TYPE STRING,
ARUN_STATUS TYPE STRING,
ALLOC_QTY TYPE STRING,
PERC_CONF_BASE TYPE STRING,
PERC_ALLOC_BASE TYPE STRING,
TVAKT_BEZEI TYPE STRING,
KUNNR TYPE STRING,
KUNNR_NAME1 TYPE STRING,
TVKOT_VTEXT TYPE STRING,
VTWEG TYPE STRING,
TVTWT_VTEXT TYPE STRING,
SPART TYPE STRING,
TSPAT_VTEXT TYPE STRING,
EDATU TYPE STRING,
BSTKD TYPE STRING,
CELLTAB TYPE STRING,
STOCK_SOURCE TYPE STRING,
ARUN_STATUS_DESC TYPE STRING,
STOCK_SOURCE_DESC TYPE STRING,
RESWK TYPE STRING,
WERKS TYPE STRING,
VSTEL TYPE STRING,
EKORG TYPE STRING,
EKGRP TYPE STRING,
EINDT TYPE STRING,
RETPO TYPE STRING,
MENGE TYPE STRING,
CNFM_QTY TYPE STRING,
LMEIN TYPE STRING,
AKTNR TYPE STRING,
SUNMI TYPE STRING,
ABELN TYPE STRING,
ABELP TYPE STRING,
SIZE1 TYPE STRING,
SIZE1_DESC TYPE STRING,
SIZE2 TYPE STRING,
SIZE2_DESC TYPE STRING,
COLOR TYPE STRING,
COLOR_DESC TYPE STRING,
WAKT_AKTKT TYPE STRING,
T024_EKNAM TYPE STRING,
T024E_EKOTX TYPE STRING,
RFM_OTHER_GRP TYPE STRING,
COLOR_ATINN TYPE STRING,
SIZE1_ATINN TYPE STRING,
SIZE2_ATINN TYPE STRING,END OF T_EKKO_STR. DATA: WA_RFM_PSST_VIS_VALV_STO_S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-EBELN sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-EBELP sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-BSART sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-VKORG sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-UEPOS sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-T001W_NAME1 sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-FSH_SEASON_YEAR sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-FSH_SEASON sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-RFM_SEASON_DESC sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-FSH_COLLECTION sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-RFM_COLLECTION_DES sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-FSH_THEME sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-RFM_THEME_DESC sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-RFM_PSST_RULE sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-RFM_PSST_GROUP sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-MATNR sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-MAKTX sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-MATKL sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-SGT_RCAT sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-REQQTY_BU sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-MEINS sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-LFGSA sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-ATTYP sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-SATNR sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-DISP_MATNR sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-DISP_MATNR_MAKTX sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-ARUN_STATUS sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-ALLOC_QTY sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-PERC_CONF_BASE sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-PERC_ALLOC_BASE sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-TVAKT_BEZEI sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-KUNNR sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-KUNNR_NAME1 sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-TVKOT_VTEXT sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-VTWEG sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-TVTWT_VTEXT sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-SPART sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-TSPAT_VTEXT sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-EDATU sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-BSTKD sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-CELLTAB sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-STOCK_SOURCE sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-ARUN_STATUS_DESC sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-STOCK_SOURCE_DESC sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-RESWK sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-WERKS sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-VSTEL sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-EKORG sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-EKGRP sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-EINDT sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-RETPO sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-MENGE sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-CNFM_QTY sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-LMEIN sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-AKTNR sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-SUNMI sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-ABELN sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-ABELP sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-SIZE1 sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-SIZE1_DESC sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-SIZE2 sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-SIZE2_DESC sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-COLOR sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-COLOR_DESC sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-WAKT_AKTKT sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-T024_EKNAM sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-T024E_EKOTX sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-RFM_OTHER_GRP sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-COLOR_ATINN sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-SIZE1_ATINN sy-vline
WA_RFM_PSST_VIS_VALV_STO_S_STR-SIZE2_ATINN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.